Shear Strength and Seismic Behavior of the Composite Shear Wall with the Steel Plate Embedded in the RC Wall

철판삽입 합성전단벽의 전단강도와 내진거동

  • 천영수 (한국토지주택공사 토지주택연구원) ;
  • 박지영 (한국토지주택공사 토지주택연구원) ;
  • 이종윤 (한국토지주택공사 수도권주택센터)
  • Received : 2017.03.02
  • Accepted : 2017.07.29
  • Published : 2017.07.30

Abstract

This study proposed hybrid coupled shear wall in the steel plate insertion method, which is capable of reinforcing the shear strength of the entire wall without increasing wall thickness in the wall-slab apartment buildings. The proposed hybrid coupled shear wall was tested for its effectiveness, shear strength and seismic behavior in experiment. As a test result, the shear strength improvement by the proposed hybrid coupled shear was found effective. Integral-type of steel plate insertion was found more effective than separate-type steel plate insertion. In this case, if the stud enforcement method proposed in this study was used, the shear strength of hybrid coupled shear wall was recommended to calculate using the KBC2016 0709.4.1(3) method. The steel plate inserted in the proposed method was found to have no significant impact on the final fracture behavior and bending strength of hybrid coupled shear wall. The shear strength at the final destruction of the wall was merely about 1/50 of the entire design shear strength. Thus, it is deemed that the wall was over excessively designed regarding the shear force in the existing design method. This finding indicates further study on wall designing to ensure effective and economic designing based on appropriate strength estimation under the destruction mechanism.

Keywords

References

  1. 대한건축학회(2016), "성능기반 내진설계 지침".
  2. 대한건축학회(2016), "건축구조 설계기준 및 해설 (KBC2016)"
  3. 한국콘크리트학회(2012), "콘크리트구조기준".
  4. 홍설걸, 이동훈, 이승준, 이명재, 김원기(2007), "내진 설계를 위한 합성벽체의 전단강도 특성 ", 한국지진공학회 춘계학술발표회 논문집, pp.240-247
  5. Hongsong Hu, Jianguo Nie, and Jiansheng Fan(2012), "Seismic behavior of steel plate-concrete composite shear walls", 15th World Conference on Earthquake Engineering, Lisbon, Portugal.
  6. Ding, C.H., Jiang, H.C., Zeng, J., Zhang, H.D. and Du, G.(2011), "An innovation application of SCS composite wall:Structural design of Yancheng TV tower", Building Structure, 41(12):81-91
  7. Liu, P., He, W.M., Guo, J.Y. and Guo, W.B.(2009), "Structural design of the mega tower of china world trade center(phase 3A)", Journal of building structures, Supplementary issue 1.
  8. Sun, J.C., Wang, Y., Sun, H.Z. and Chen, Y.(2011), "Application of steel plate concrete composite wall in national museum of china", Building Structure, 41(6):14-19
  9. Wright, H.D. and Gallocher, S.C.(1995), "The behavior of composite walling under construction and service loading", Journal of Constructional Steel Research, 35(3):257-273 https://doi.org/10.1016/0143-974X(94)00051-I
  10. 천영수, 박지영, 이선웅(2015), "성능기반설계법의 도입을 위한 부재별 비선형이력모델 개발(1)", 토지주택연구원 연구보고서
  11. ACI T1.1R-01(2001), "Commentary on Acceptance Criteria for Moment Frames Based on Structural Testing", American Concrete Institute.