Radial Electrical Impedance: A Potential Indicator for Noninvasive Cuffless Blood Pressure Measurement

  • Huynh, Toan Huu (Department of Electronic Engineering, Pukyong National University) ;
  • Chung, Wan-Young (Department of Electronic Engineering, Pukyong National University)
  • Received : 2017.07.19
  • Accepted : 2017.07.27
  • Published : 2017.07.31

Abstract

Noninvasive, cuffless, and continuous blood pressure (BP) monitoring is essential to prevent and control hypertension. A well-known existing method for this measurement is pulse transit time (PTT), which has been investigated by many researchers as a promising approach. However, the fundamental principle of the PTT method is based on the time interval taken by a pulse wave to propagate between the proximal and distal arterial sites. Consequently, this method needs an independent system with two devices placed at two different sites, which is a problem. Even though some studies attempted to synchronize the system, it is bulky and inconvenient by contemporary standards. To find a more sensitive method to be used in a BP measurement device, this study used radial electrical bioimpedance (REB) as a potential indicator for BP determination. Only one impedance plethysmography channel at the wrist is performed for demonstrating a ubiquitous BP wearable device. The experiment was evaluated on eight healthy subjects with the ambulatory BP monitor on the upper arm as a reference. The results demonstrated the potential of the proposed method by the correlation of estimated systolic (SBP) and diastolic (DBP) BP against the reference at $0.84{\pm}0.05$ and $0.83{\pm}0.05$, respectively. REB also tracked the DBP well with a root-mean-squared-error of $7.5{\pm}1.35mmHg$.

Keywords

References

  1. P. M. Kearney, M. Whelton, K. Reynolds, P. Muntner, P. K. Whelton, and J. He, "Global burden of hypertension: analysis of worldwide data," The Lancet, vol. 365, pp. 217-223, 2005. https://doi.org/10.1016/S0140-6736(05)70151-3
  2. X. Ding, Y. Zhang, J. Liu, W. Dai, and H. Tsang, "Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio," IEEE Trans. Biomed. Eng., 2015.
  3. R. Smith, J. Argod, J. Pepin, and P. Levy, "Pulse transit time: an appraisal of potential clinical applications," Thorax, vol. 54, pp. 452-457, 1999. https://doi.org/10.1136/thx.54.5.452
  4. L. Geddes, M. Voelz, C. Babbs, J. Bourland, and W. Tacker, "Pulse transit time as an indicator of arterial blood pressure," Psychophysiology, vol. 18, pp. 71-74, 1981. https://doi.org/10.1111/j.1469-8986.1981.tb01545.x
  5. H. Gesche, D. Grosskurth, G. Küchler, and A. Patzak, "Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method," Eur. J. Appl. Physiol., vol. 112, pp. 309-315, 2012. https://doi.org/10.1007/s00421-011-1983-3
  6. D. Hughes, C. Babbs, L. Geddes, and J. Bourland, "Measurements of Young's Modulus of Elasticity of the Canine Aorta with Ultrasound," Ultrasonic Imaging, vol. 1, pp. 356-367, 1979. https://doi.org/10.1177/016173467900100406
  7. D. McCombie, A. Reisner, H. Asada, and P. Shaltis, "Wearable Pulse Wave Velocity Blood Pressure Sensor and Methods of Calibration Thereof," 2007.
  8. C. Kim, A. Carek, R. Mukkamala, O. Inan, and J. Hahn, "Ballistocardiogram as Proximal Timing Reference for Pulse Transit Time Measurement: Potential for Cuffless Blood Pressure Monitoring," IEEE Trans. Biomed. Eng., vol. 62, pp. 2657-2664, 2015. https://doi.org/10.1109/TBME.2015.2440291
  9. R. Mukkamala, J.-O. Hahn, O. T. Inan, L. K. Mestha, C.-S. Kim, H. Töreyin, et al., "Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice," IEEE Trans. Biomed. Eng., vol. 62, pp. 1879-1901, 2015. https://doi.org/10.1109/TBME.2015.2441951
  10. W. Chen, T. Kobayashi, S. Ichikawa, Y. Takeuchi, and T. Togawa, "Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration," Med Biol Eng Comput, vol. 38, p. 569, 2000. https://doi.org/10.1007/BF02345755
  11. G. Zhang, M. Gao, D. Xu, N. Olivier, and R. Mukkamala, "Pulse arrival time is not an adequate surrogate for pulse transit time as a marker of blood pressure," J. Appl. Physiol., vol. 111, p. 1681, 2011. https://doi.org/10.1152/japplphysiol.00980.2011
  12. J. Sola, M. Proenca, D. Ferrario, J. Porchet, A. Falhi, O. Grossenbacher, et al., "Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor," IEEE Trans. Biomed. Eng., vol. 60, p. 3505, 2013. https://doi.org/10.1109/TBME.2013.2272699
  13. L. Djordjevich, M. Sadove, J. Mayoral, and A. Ivankovich, "Correlation between arterial blood pressure levels and (dZ/ dt) min in impedance plethysmography," IEEE Trans. Biomed. Eng., vol. 32, p. 69, 1985.
  14. M. Theodor, D. Ruh, M. Ocker, D. Spether, K. Förster, C. Heilmann, et al., "Implantable Impedance Plethysmography," Sensors, vol. 14, p. 14858, 2014. https://doi.org/10.3390/s140814858
  15. J. NYBOER, "Electrical impedance plethysmography," Circulation, vol. 2, p. 811, 1950. https://doi.org/10.1161/01.CIR.2.6.811
  16. D. Bergel, "The static elastic properties of the arterial wall," J. Physiol., vol. 156, p. 445, 1961. https://doi.org/10.1113/jphysiol.1961.sp006686
  17. N. Fazeli and J. Hahn, "Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal," Front. Psychol., vol. 3, p. 298, 2012.
  18. J. Pfitzner, "Poiseuille and his law," Anaesthesia, vol. 31, p. 273, 1976. https://doi.org/10.1111/j.1365-2044.1976.tb11804.x
  19. T. Master, "Medical electrical equipment Part 1: General requirements for basic safety and essential performance," 2012.
  20. R. Omron, "Automatic blood pressure monitor with Com- FitTM cuff: Model HEM-790IT," Omron Healthcare Inc., Bannockburn, IL, 2006.
  21. A. Coleman, S. Steel, P. Freeman, A. de Greeff, and A. Shennan, "Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol," Blood Press Monit, vol. 13, p. 49, 2008. https://doi.org/10.1097/MBP.0b013e3282cb57b6
  22. R. El Feghali, J. Topouchian, B. Pannier, H. El Assaad, and R. Asmar, "Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension," Blood Press Monit, vol. 12, p. 173, 2007. https://doi.org/10.1097/MBP.0b013e3280b08367
  23. G. Langewouters, K. Wesseling, and W. Goedhard, "The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model," J Biomech, vol. 17, p. 425, 1984. https://doi.org/10.1016/0021-9290(84)90034-4