DOI QR코드

DOI QR Code

An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom

욕실과 인접한 아파트 드레스룸의 결로 원인 분석

  • Choi, Young-Woo (Graduate School of Housing and Urban Planning, Seoul National University of Science and Technology) ;
  • Kim, Sean Hay (Architectural Engineering Program, Seoul National University of Science and Technology)
  • Received : 2017.07.19
  • Accepted : 2017.08.18
  • Published : 2017.08.30

Abstract

Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

Keywords

References

  1. 오세민 외, "공동주택 결로 하자 사례를 통한 개선방안 도출", 설비공학논문집 제29권 제2호, 2017.2. // (Oh, Semin, Study on the Improvement Plans of Condensation Defect Examples in Apartment Building, Korean Journal of Air-Conditioning and Refrigeration Engineering Vol. 29, No. 2(2017))
  2. 국토교통부, "공동주택 결로방지를 위한 설계기준", 2016 // (MOLIT, "Standard of a design for preventing the condensation in multi-residential house", 2016)
  3. 이연화 외, "공동주택의 붙박이장 설치 공간에서 결로 발생 현상 진단을 위한 동계 실내 온열 환경 평가", 대한건축학회 논문집 - 계획계 32(7), 2016.7. // (Lee, Hyun-Hwa, Evaluation on the Thermal Environment for Condensation Problem Diagnosis around Built-in Furniture of Apartment Buildings in Winter, JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Planning & Design 32(7), 2016)
  4. 김예진 외, "실측을 통한 욕실 사용 후 드레스룸 및 붙박이장 온습도 환경 분석", 대한건축학회 학술발표대회 논문집, 2016. // (Kim, Ye Jin, Analysis environmental change of built-in wardrobe and dressroom space after using bathroom space by field measurement, ARCHITECTURAL INSTITUTE OF KOREA, 2016)
  5. 오세민 외, "벽체 결로 하자 사례와 시뮬레이션을 통한 결로 방지 성능 평가 방법 개선방안", 대한설비공학회 2016년도 하계학술발표대회논문집, 2016.6. // (Oh, Semin, Study on the Improvement of Evaluation of Preventing the Condensation in through Condensation Defect Example and Thermal Environment Simulation, The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, 2016)
  6. Lawrence Berkeley National Laboratory, THERM (http://windows.lbl.gov/software/therm)