Abstract

Pressurized membrane module systems, including hollow fiber type of Microfiltration (MF) and Ultrafiltration (UF) membranes are being increasingly used in drinking water treatment due to their high removal efficiency of pathogen. However, when fibers are damaged in pressurized membrane system, the pathogen will be able to penetrate the membrane. Therefore, it is essential to guarantee the regulatory requirements for water quality by an effective on-line or off-line condition integrity monitoring methods. Recently, pressure decay test (PDT) which is one of membrane integrity tests has been reflected to drinking water treatment plants using pressurized membrane module. In this paper, three different method were used to perform PDT and three different sensitivity values were analyzed through experiments. Three types of direct integrity test methods were applied to pressure feed side, filtrate side and bidirectional pressure decay test. The results of these experiments show that the sensitivity was increasing when the volume of pressurized gas was decreasing. The sensitivity is inversely proportional to the gas volume. Furthermore, it is desirable to increase pressure difference between feed side and permeate side in order to achieve higher sensitivity in the PDT by membrane damage.

중공사형 정밀여과(MF)와 한외여과(UF)를 포함한 가압식 막여과 시스템은 높은 수준의 병원균 제거 효율로 인해 음용수 처리에 점점 더 많이 사용되고 있다. 그러나 가압식 막여과 시스템에서 분리막의 손상으로 인한 막완결성의 문제가 발생시 병원체가 유출될 수 있으므로, 효과적인 온라인 또는 오프라인 방식의 막 완결성 모니터링 방법을 통해 수질의 안정성을 보장하여야 한다. 최근 막 완결성 시험 중 하나 인 압력손실시험(pressure decay test, PDT)이 가압식 분리막 모듈을 이용한 음용수 처리 시설에 적용되고 있다. 이 논문에서는 PDT의 기체 주입방법에 따른 세 가지 조건으로 원수 측, 여과수 측, 원수 여과수 양방향 측 세 가지 조건을 선정 후 이에 따른 감지감도를 이론값과 실험값을 적용하여 비교하였다. 실험결과 가압되는 측의 부피와 감도는 반비례함을 확인하였고, 주입부의 반대방향에 부압을 형성 시에도 감도가 증가함을 확인할 수 있다. 즉 막 손상의 감지감도는 주입되는 부분의 체적이 작아질수록, 분리막을 경계로 유입과 여과 측의 압력차가 클수록 높아짐을 알 수 있었다.

Keywords

References

  1. M. L. Pype, B. C. Donose, L. Martí, D. Patureau, N. Wery, and W. Gernjak, "Virus removal and integrity in aged RO membranes", Water Res., 90, 167 (2016). https://doi.org/10.1016/j.watres.2015.12.023
  2. A. Liden, E. Lavonen, K. M. Persson, and M. Larson, "Integrity breaches in a hollow fiber nanofilter- Effects on natural organic matter and virus- like particle removal", Water Res., 105, 231 (2016). https://doi.org/10.1016/j.watres.2016.08.056
  3. K. Farahbakshs and D. W. Smith, "Estimating air diffusion contribution to pressure decay during membrane integrity tests", J. Membr. Sci., 237, 203 (2004). https://doi.org/10.1016/j.memsci.2004.03.015
  4. O. Ferrer, R. Casas, C. Galvan, F. Lucena, A. Vega, O. Gibert, J. Jofre, and X. Bernat, "Challenge tests with virus surrogates: an accurate membrane integrity evaluation system?", Desalination and Water Treat., 51, 25 (2013).
  5. USEPA, "Membrane Filtration Guidance Manual", USEPA 815-R-06-009 (2005).
  6. J. Naismith, "Membrane integrity-direct turbidity measurement of filtrate from MF membrane modules at an operating potable water treatment plant", Desalination, 179, 25 (2005). https://doi.org/10.1016/j.desal.2004.11.052
  7. J. H. Lee, S. K. Hong, H. C. Hur, K. J. Lee, and Y. J. Choi, "Sensitivity analysis of initial pressure and upper control limit on the pressure decay test for membrane integrity evaluation", Sujil Bojeon., 179, 793 (2008).
  8. H. Guo, Y. Wyart, J. Perot, F. Nauleau, and P. Moulin, "Low-pressure membrane integrity tests for drinking water treatment: A review", Water Res., 44, 41 (2010). https://doi.org/10.1016/j.watres.2009.09.032
  9. S. J. You, H. W. Ahn, S. H. Park, J. L. Lim, S. C. Hong, and P. I. Yi, "The study on optimum operation conditions of ceramic MF membrane process in Y water treatment plant", Membr. J., 24, 201 (2014). https://doi.org/10.14579/MEMBRANE_JOURNAL.2014.24.3.201
  10. S. Wang, X. Lu, N. Zhou, W. Xiong, Q. Zhang, and Z. Yang, "Quantification of the defect size of ultrafiltration membrane system using mathematical model", Desalination, 367, 172 (2015). https://doi.org/10.1016/j.desal.2015.04.007