DOI QR코드

DOI QR Code

단순 해석 모델을 이용한 밸브지지대 내진 성능 평가

Seismic Performance Evaluation of Valve Support using Simplified FE Model

  • 김상영 (군산대학교 기계자동차조선해양공학부) ;
  • 금동엽 (안동대학교 기계공학과) ;
  • 김형은 (안동대학교 기계공학과) ;
  • 김대진 (안동대학교 기계공학과) ;
  • 김준호 (한국가스공사 연구개발원) ;
  • 홍성경 (한국가스공사 연구개발원) ;
  • 최원목 (한국가스공사 연구개발원) ;
  • 석창성 (성균관대학교 기계공학과)
  • Kim, Sang-Young (School of Mechanical & Automotive Engineering and Naval Architecture, Kunsan National University) ;
  • Keum, Dong Yeop (Department of Mechanical Engineering, Andong National University) ;
  • Kim, Hyoung Eun (Department of Mechanical Engineering, Andong National University) ;
  • Kim, Dae Jin (Department of Mechanical Engineering, Andong National University) ;
  • Kim, Jun Ho (Department of Research & Development, Korea Gas Cooperation) ;
  • Hong, Seong Kyeong (Department of Research & Development, Korea Gas Cooperation) ;
  • Choi, Won Mok (Department of Research & Development, Korea Gas Cooperation) ;
  • Seok, Chang Sung (Department of Mechanical Engineering, Sungkyunkwan University)
  • 투고 : 2016.09.22
  • 심사 : 2017.01.23
  • 발행 : 2017.02.28

초록

In this study, a simplified FE model for evaluating seismic performance of valve support was suggested and an apparatus for a real structure testing was developed. The seismic performances of three different types of valve supports were evaluated by the real structure testing. By comparing the results between the real structure testing and FEA using the simplified FE model, it was verified that the suggested simplified FE model can be utilized for comparative evaluation of seismic performance of valve supports.

키워드

참고문헌

  1. KOGAS-GSD-2031, "Standard for Seismic Design of Supply Station and Gas Pipes," Korea Gas Corporation, 2011.
  2. D. H. Lee, K. S. Cho, T. Y. Chung and J. S. Kong, "Earthquake Response Analysis of a Buried Gas Pipeline", Earthquake Engineering Society of Korea, Vol. 11, No. 6, pp. 41-52, 2007. https://doi.org/10.5000/EESK.2007.11.6.041
  3. H. E. Kim, D. Y. Keum, D. J. Kim, J. H. Kim, S. K. Hong, W. M. Choi, S. Y. Kim and C. S. Seok, "Design Optimization of Valve Support with Enhanced Seismic Performance," Journal of the Korean Society for Precision Engineering, Vol. 32, No. 11, pp. 997-1005, 2015. https://doi.org/10.7736/KSPE.2015.32.11.997
  4. D. K. Lee, "Structural Mechanics for the Seismic Design of Buildings(I, II)," The Korean Structural Engineers Association, Vol. 13, No. 1, 2006.
  5. Y. -G. Kim, T. -H. Kwon, Y. -J. Jeong, H. -T. Kim and Y. -J. Kim, "Study on Seismic Analysis and Test for Seismic Qualification of 245kV GIS," Transaction of the Korean Society of Mechanical Engineers: A, Vol. 37, No. 5, 2013.
  6. J. Koh, S. Hong, J. Kim and S. Jeong, "The Estimation of Earthquake-Resistance for Gas Utility using Equivalent Static Analysis," Journal of the Korean Institute of Gas, Vol. 6, No. 4, pp. 23-32, 2002.
  7. ANSYS Mechanical User's Guide
  8. S. Chirag, "Types of Contacts in ANSYS," https://sites.google.com/site/mechanicalengineeringforlife/FEA/typesofcontactsinansys
  9. J. H. Kim, S. K. Hong, D. J. Kim, H. E. Kim and W. M. Choi, "Testing Apparatus for Evaluating Seismic Performance", Patent, Korean Patent, 10-2015-0034516.