DOI QR코드

DOI QR Code

Maximum Power Tracking Control for parallel-operated DFIG Based on Fuzzy-PID Controller

  • Gao, Yang (Dept. of Electrical Engineering, Shanghai Jiaotong University) ;
  • Ai, Qian (Dept. of Electrical Engineering, Shanghai Jiaotong University)
  • Received : 2017.05.31
  • Accepted : 2017.08.01
  • Published : 2017.11.01

Abstract

As constantly increasing wind power penetrates power grid, wind power plants (WPPs) are exerting a direct influence on the traditional power system. Most of WPPs are using variable speed constant frequency (VSCF) wind turbines equipped with doubly fed induction generators (DFIGs) due to their high efficiency over other wind turbine generators (WTGs). Therefore, the analysis of DFIG has attracted considerable attention. Precisely measuring optimum reference speed is basis of utilized maximum wind power in electric power generation. If the measurement of wind speed can be easily taken, the reference of rotation speed can be easily calculated by known system's parameters. However, considering the varying wind speed at different locations of blade, the turbulence and tower shadow also increase the difficulty of its measurement. The aim of this study is to design fuzzy controllers to replace the wind speedometer to track the optimum generator speed based on the errors of generator output power and rotation speed in varying wind speed. Besides, this paper proposes the fuzzy adaptive PID control to replace traditional PID control under rated wind speed in variable-pitch wind turbine, which can detect and analyze important aspects, such as unforeseeable conditions, parameters delay and interference in the control process, and conducts online optimal adjustment of PID parameters to fulfill the requirement of variable pitch control system.

Keywords

References

  1. Aissaoui, Ghani A, Abid, et al, "A Fuzzy-PI control to extract an optimal power from wind turbine," Energy Conversion & Management, vol. 65, no. 1, pp. 688-696, Jan.2013. https://doi.org/10.1016/j.enconman.2011.11.034
  2. Liu Y, Wu Q H, Zhou X X, "Co-ordinated Multiloop Switching Control of DFIG for Resilience Enhancement of Wind Power Penetrated Power Systems," IEEE Transactions on Sustainable Energy, vol. 7, no. 3, pp. 1089-1099, Jul.2016. https://doi.org/10.1109/TSTE.2016.2524683
  3. Ramirez-Gonzalez M, Malik O, Castellanos-Bustamante R, et al, "Conventional and fuzzy PODCs for DFIG-based wind farms and their impact on inter-area and torsional oscillation damping," IET Renewable Power Generation, vol. 11, no. 2, pp. 334-340, Jan.2017. https://doi.org/10.1049/iet-rpg.2016.0138
  4. Hu J, Huang Y, Wang D, et al, "Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability Analysis," IEEE Trans. on Sustainable Energy, vol. 6, no. 4, pp. 1325-1336, Jun. 2015. https://doi.org/10.1109/TSTE.2015.2432062
  5. Ghosh S, Kamalasadan S, "An Energy Function-Based Optimal Control Strategy for Output Stabilization of Integrated DFIG-Flywheel Energy Storage System," IEEE Transactions on Smart Grid, vol. 8, no. 4, pp. 1922-1931, Jul.2017. https://doi.org/10.1109/TSG.2015.2510866
  6. Ansari J, Jamei M, Kazemi A, "Integration of the wind power plants through a novel, multi-objective control scheme under the normal and emergency conditions," International Transactions on Electrical Energy Systems, vol. 26, no. 8, pp. 1752-1782, Jan. 2016. https://doi.org/10.1002/etep.2176
  7. Xu J, Sun H, Gao W D, et al, "Modeling of wind farm output considering wind speed spatiotemporal distribution and wind turbine operational statuses," International Transactions on Electrical Energy Systems, 2016, vol. 26, no. 7, pp. 1526-1539, Nov. 2015.
  8. Tripathi S M, Tiwari A N, Singh D, "Optimum design of proportional-integral controllers in grid-integrated PMSG-based wind energy conversion system," International Transactions on Electrical Energy Systems, vol. 26, no. 5, pp. 1006-1031, Aug. 2016. https://doi.org/10.1002/etep.2120
  9. Zhu D, Zou X, Deng L, et al, "Inductance-emulating Control for DFIG-Based Wind Turbine to Ridethrough Grid Faults," IEEE Transactions on Power Electronics, vol. 32, no. 11, pp. 8514-8525, Dec, 2016. https://doi.org/10.1109/TPEL.2016.2645791
  10. Kaloi G S, Wang J, Baloch M H., "Dynamic Modeling and Control of DFIG for Wind Energy Conversion System Using Feedback Linearization," Journal of Electrical Engineering & Technology, vol. 11, no. 5, pp. 1137-1146, Sep.2016. https://doi.org/10.5370/JEET.2016.11.5.1137
  11. Lee S E, Won D J, Chung I Y, "Operation Scheme for a Wind Farm to Mitigate Output Power Variation," Journal of Electrical Engineering & Technology, vol. 7, no. 6, pp. 869-875, Nov.2012. https://doi.org/10.5370/JEET.2012.7.6.869
  12. Patnaik R K, Dash P K, Mahapatra K, "Adaptive terminal sliding mode power control of DFIG based wind energy conversion system for stability enhancement," International Transactions on Electrical Energy Systems, vol. 26, no. 4, pp. 750-782, Jun.2015.
  13. Byeon G, Park I K, Jang G, "Modeling and Control of a Doubly-Fed Induction Generator (DFIG) Wind Power Generation System for Real-time Simulations," Journal of Electrical Engineering & Technology, vol. 5, no. 1, pp. 61-69, Mar.2010. https://doi.org/10.5370/JEET.2010.5.1.061
  14. Govindaraj N, Raghava D, "Doubly Fed Induction Generator Based Wind Turbine with Adaptive Neuro Fuzzy Inference System Controller," Asian Journal of Scientific Research, vol. 7, no. 1, pp. 45-55, Jan.2014. https://doi.org/10.3923/ajsr.2014.45.55
  15. Du W, Bi J, Cao J, et al, "A Method to Examine the Impact of Grid Connection of the DFIGs on Power System Electromechanical Oscillation Modes," IEEE Transactions on Power Systems, vol. 31, no. 5, pp. 3775-3784, Sep. 2016. https://doi.org/10.1109/TPWRS.2015.2494082
  16. Lee H, Kim J, Hur D, et al, "Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation," Journal of Electrical Engineering & Technology, vol. 10, no. 2, pp. 496-503, Mar. 2015. https://doi.org/10.5370/JEET.2015.10.2.496