DOI QR코드

DOI QR Code

Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters

부자식 수위계를 위한 이동형 교정시스템의 수학 모델

  • Received : 2017.06.09
  • Accepted : 2017.07.18
  • Published : 2017.10.31

Abstract

K-water have been operating as an International accredited calibration organization for ISO 17025 regarding float, ultrasonic and radar type since 2008. Due to the absence of on-site calibration system, water level meter could only be calibrated from a laboratory. Therefore K-water institute developed an mobile calibration system for water-level meter in 2015 to calibrate the water-level meter on site. The mobile calibration system was certificated by KOLAS(Korea Laboratory Accreditation Scheme) in 2016. In this paper a mobile calibration system, which is a method to calibrate float type water level meter on site, is established. A mathematical equation was derived by reviewing characteristics of standard equipment and measurement. By developing the mobile calibration system, it is possible to achieve reliability of data through scientific system operation on hydrological data.

K-water에서는 2008년부터 부자식 및 초음파, 레이다식의 수위계에 대한 ISO 17025 국제공인 교정기관을 운영하고 있다. 현재까지 수위계의 교정은 고정표준실에서 실내 교정만이 가능하였으며, 이는 현장 등의 실외에서 교정하는 시스템의 부재가 원인이었다. 따라서 현장에서도 교정이 가능하도록 2015년에 이동형 교정시스템을 개발하였으며, 2016년에 각종 심사 및 위원회를 거쳐 한국인정기구(KOLAS)로부터 인정을 받았다. 본 논문에서는 한국인정기구로부터 인정받은 수위계 이동형 교정시스템 중 부자식 수위계를 현장에서 교정할 수 있는 교정시스템에 대하여 표준기 및 측정과 관련한 제반 사항에 대하여 검토하였다. 또한 설계의 기반이 되는 수학 모델을 도출하였으며, 이동형 교정시스템 구축을 통하여 수문관측 데이터에 대한 과학적인 시스템 운영으로 측정 데이터의 신뢰성을 확보하고자 하였다.

Keywords

References

  1. Ministry of Land, Infrastructure and Transport, "Korea Annual Hydrological Report," Ministry of Land, Infrastructure and Transport, 2015.
  2. National Emergency Management Agency, "Annual Report on Disaster," National Emergency Management Agency, 2015.
  3. S. T. Hong, G. W. Shin, "Development of Portable Calibration System for Non-Contact Waters," Journal of the Korea Institute of Information and Communication Engineering, vol. 20, no. 9, pp. 1808-1815, Sep. 2016. https://doi.org/10.6109/jkiice.2016.20.9.1808
  4. G. W. Shin, S. T. Hong, "Best measurement capability and standard test facility for the water-level gauges," Journal of Control, Automation and Systems Engineering, vol. 13, no. 10, pp. 1012-1017, Oct. 2007. https://doi.org/10.5302/J.ICROS.2007.13.10.1012
  5. S. T. Hong, I. H. Kim, J. W. Choi, G. W. Shin, "Development of Float Water Level Meter Portable Calibration Systems," in 2016 Autumn Conference on Information and Communication Engineering, Daejeon, pp. 411-414, Oct. 2016.
  6. Korea Research Institute of Standards and Science, ISO/IEC GUIDE 98-3:2008, "Guide to the expression of uncertainty in measurement," GUM:1995, 2010.
  7. Korea Laboratory Accreditation Scheme, "Guidelines for maintaining the traceability of the measurement results," Korea Laboratory Accreditation Scheme, 2016.
  8. Korea Laboratory Accreditation Scheme, "Guidelines for field testing measurement uncertainty estimation," Korea Laboratory Accreditation Scheme, 2016.