Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

  • Received : 2017.01.24
  • Accepted : 2017.05.29
  • Published : 2017.10.31

Abstract

PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.

Keywords

References

  1. Dantas Ide S, Souza MB, Morais MH, Carreiro Ada F, Barbosa GA. Success and survival rates of mandibular overdentures supported by two or four implants: a systematic review. Braz Oral Res 2014;28:74-80.
  2. Kern JS, Kern T, Wolfart S, Heussen N. A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss. Clin Oral Implants Res 2016;27:174-95.
  3. Awad MA, Rashid F, Feine JS; Overdenture Effectiveness Study Team Consortium. The effect of mandibular 2-implant overdentures on oral health-related quality of life: an international multicentre study. Clin Oral Implants Res 2014;25:46-51.
  4. Harris D, Hofer S, O'Boyle CA, Sheridan S, Marley J, Benington IC, Clifford T, Houston F, O'Connell B. A comparison of implant-retained mandibular overdentures and conventional dentures on quality of life in edentulous patients: a randomized, prospective, within-subject controlled clinical trial. Clin Oral Implants Res 2013;24:96-103. https://doi.org/10.1111/j.1600-0501.2011.02368.x
  5. Thomason JM. The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life. J Evid Based Dent Pract 2012;12:182-4.
  6. Hobkirk JA, Abdel-Latif HH, Howlett J, Welfare R, Moles DR. Prosthetic treatment time and satisfaction of edentulous patients treated with conventional or implant-stabilized complete mandibular dentures: a case-control study (part 2). Int J Prosthodont 2009;22:13-9.
  7. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais J, Naert I, Payne AG, Penrod J, Stoker GT, Tawse-Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int J Oral Maxillofac Implants 2002;17:601-2.
  8. Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement. Br Dent J 2009;207:185-6. https://doi.org/10.1038/sj.bdj.2009.728
  9. Hong HR, Pae A, Kim Y, Paek J, Kim HS, Kwon KR. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis. Int J Oral Maxillofac Implants 2012;27:e69-76.
  10. Taylor TD. Indications and treatment planning for mandibular implant overdentures. In: Feine JS, Carlsson GE (eds). Implant Overdentures as the Standard of Care for Edentulous Patients. Chicago: Quintessence 2003. p. 71-81.
  11. Elsyad MA, Hammouda NI. Expansion of mandibular knifeedge ridge and simultaneous implant placement to retain overdentures: One-year clinical and radiographic results of a prospective study. Clin Implant Dent Relat Res 2017;19:167-79. https://doi.org/10.1111/cid.12436
  12. Thomason JM. The use of mandibular implant-retained overdentures improve patient satisfaction and quality of life. J Evid Based Dent Pract 2010;10:61-3. https://doi.org/10.1016/j.jebdp.2009.11.022
  13. Ellis JS, Burawi G, Walls A, Thomason JM. Patient satisfaction with two designs of implant supported removable overdentures; ball attachment and magnets. Clin Oral Implants Res 2009;20:1293-8. https://doi.org/10.1111/j.1600-0501.2009.01810.x
  14. Carlsson GE. Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws. J Adv Prosthodont 2014;6:245-52. https://doi.org/10.4047/jap.2014.6.4.245
  15. Cakarer S, Can T, Yaltirik M, Keskin C. Complications associated with the ball, bar and Locator attachments for implantsupported overdentures. Med Oral Patol Oral Cir Bucal 2011; 16:e953-9.
  16. Ozan O, Ramoglu S. Effect of implant height differences on different attachment types and peri-implant bone in mandibular two-implant overdentures: 3D finite element study. J Oral Implantol 2015;41:e50-9. https://doi.org/10.1563/AAID-JOI-D-13-00239
  17. Cristache CM, Muntianu LA, Burlibasa M, Didilescu AC. Five-year clinical trial using three attachment systems for implant overdentures. Clin Oral Implants Res 2014;25:e171-8. https://doi.org/10.1111/clr.12086
  18. Elsyad MA, Agha NN, Habib AA. Retention and stability of implant-retained mandibular overdentures using different types of resilient attachments: An in vitro study. Int J Oral Maxillofac Implants 2016;31:1040-8.
  19. Kleis WK, Kammerer PW, Hartmann S, Al-Nawas B, Wagner W. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Clin Implant Dent Relat Res 2010;12:209-18.
  20. Chung KH, Chung CY, Cagna DR, Cronin RJ Jr. Retention characteristics of attachment systems for implant overdentures. J Prosthodont 2004;13:221-6. https://doi.org/10.1111/j.1532-849X.2004.04042.x
  21. Uludag B, Polat S, Sahin V, Comut AA. Effects of implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures. Int J Oral Maxillofac Implants 2014;29:1053-7. https://doi.org/10.11607/jomi.3401
  22. Daas M, Dubois G, Bonnet AS, Lipinski P, Rignon-Bret C. A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations. Med Eng Phys 2008;30:218-25. https://doi.org/10.1016/j.medengphy.2007.02.005
  23. Arat Bilhan S, Bilhan H, Bozdag E, Sunbuloglu E, Baykasoglu C, Kutay O. The influence of the attachment type and implant number supporting mandibular overdentures on stress distribution: an in vitro study, part I. Implant Dent 2013;22: 39-48. https://doi.org/10.1097/ID.0b013e31827774ee
  24. Kuoppala R, Napankangas R, Raustia A. Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14): a Survey of 58 Patients. J Oral Maxillofac Res 2013;4:e4.
  25. Roccuzzo M, Bonino F, Gaudioso L, Zwahlen M, Meijer HJ. What is the optimal number of implants for removable reconstructions? A systematic review on implant-supported overdentures. Clin Oral Implants Res 2012;23:229-37. https://doi.org/10.1111/j.1600-0501.2012.02544.x
  26. Engelhardt F, Zeman F, Behr M, Hahmel S. Prosthetic complications and maintenance requirements in locator-attached implant-supported overdentures: A retrospective study. Eur J Prosthodont Restor Dent 2016;24:31-5.
  27. Andreiotelli M, Att W, Strub JR. Prosthodontic complications with implant overdentures: a systematic literature review. Int J Prosthodont 2010;23:195-203.
  28. Liu J, Pan S, Dong J, Mo Z, Fan Y, Feng H. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis. J Dent 2013;41:241-9. https://doi.org/10.1016/j.jdent.2012.11.008
  29. Gross MD. Occlusion in implant dentistry. A review of the literature of prosthetic determinants and current concepts. Aust Dent J 2008;53:S60-8. https://doi.org/10.1111/j.1834-7819.2008.00043.x
  30. Kim Y, Oh TJ, Misch CE, Wang HL. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale. Clin Oral Implants Res 2005;16:26-35.
  31. Mericske-Stern RD, Taylor TD, Belser U. Management of the edentulous patient. Clin Oral Implants Res 2000;11:108-25. https://doi.org/10.1034/j.1600-0501.2000.011S1108.x
  32. Petropoulos VC, Smith W. Maximum dislodging forces of implant overdenture stud attachments. Int J Oral Maxillofac Implants 2002;17:526-35.
  33. Rutkunas V, Mizutani H, Takahashi H. Influence of attachment wear on retention of mandibular overdenture. J Oral Rehabil 2007;34:41-51. https://doi.org/10.1111/j.1365-2842.2006.01640.x
  34. Lekholm U, Zarb GA. Patient selection and preparation. In: Branemak PI, Zarb GA, Albrektsson T, eds. Tissue integrated prostheses: osseointegration in clinical dentistry, Chicago: Quintessence; 1985, p. 199-210.
  35. Rentsch-Kollar A, Huber S, Mericske-Stern R. Mandibular implant overdentures followed for over 10 years: patient compliance and prosthetic maintenance. Int J Prosthodont 2010; 23:91-8.
  36. Dashti MH, Atashrazm P, Emadi MI, Mishaeel S, Banava S. The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis. Quintessence Int 2013;44:585-90.
  37. Kono K, Kurihara D, Suzuki Y, Ohkubo C. In vitro assessment of mandibular single/two implant-retained overdentures using stress-breaking attachments. Implant Dent 2014; 23:456-62.
  38. Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001;85:585-98. https://doi.org/10.1067/mpr.2001.115251
  39. Greco GD, Jansen WC, Landre Junior J, Seraidarian PI. Biomechanical analysis of the stresses generated by different disocclusion patterns in an implant-supported mandibular complete denture. J Appl Oral Sci 2009;17:515-20. https://doi.org/10.1590/S1678-77572009000500029
  40. Baggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. J Prosthet Dent 2008;100:422-31. https://doi.org/10.1016/S0022-3913(08)60259-0
  41. Chun HJ, Park DN, Han CH, Heo SJ, Heo MS, Koak JY. Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments. J Oral Rehabil 2005;32:193-205. https://doi.org/10.1111/j.1365-2842.2004.01407.x
  42. de Almeida EO, Rocha EP, Assuncao WG, Junior AC, Anchieta RB. Cortical bone stress distribution in mandibles with different configurations restored with prefabricated barprosthesis protocol: a three-dimensional finite-element analysis. J Prosthodont 2011;20:29-34. https://doi.org/10.1111/j.1532-849X.2010.00656.x
  43. Ebadian B, Farzin M, Talebi S, Khodaeian N. Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: A finite element analysis. Dent Res J (Isfahan) 2012;9:741-7.
  44. Chung KH, Whiting D, Kronstrom M, Chan D, Wataha J. Retentive characteristics of overdenture attachments during repeated dislodging and cyclic loading. Int J Prosthodont 2011;24:127-9.
  45. Stergiou A, Juszczyk AS, Clark RK, Radford DR. The retentive forces of the locator attachment system at different angulations. Eur J Prosthodont Restor Dent 2012;20:168-74.
  46. Al-Ghafli SA, Michalakis KX, Hirayama H, Kang K. The in vitro effect of different implant angulations and cyclic dislodgement on the retentive properties of an overdenture attachment system. J Prosthet Dent 2009;102:140-7. https://doi.org/10.1016/S0022-3913(09)60134-7
  47. Rabbani S, Juszczyk AS, Clark RK, Radford DR. Investigation of retentive force reduction and wear of the locator attachment system with different implant angulations. Int J Oral Maxillofac Implants 2015;30:556-63. https://doi.org/10.11607/jomi.3687
  48. Barao VA, Delben JA, Lima J, Cabral T, Assuncao WG. Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible-a computed tomography-based three-dimensional finite element analysis. J Biomech 2013;46:1312-20. https://doi.org/10.1016/j.jbiomech.2013.02.008
  49. Elsyad MA, Setta FA, Khirallah AS. Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study. J Adv Prosthodont 2016;8:116-24. https://doi.org/10.4047/jap.2016.8.2.116
  50. Jayaraman S, Mallan S, Rajan B, Anachaperumal MP. Threedimensional finite element analysis of immediate loading mini over denture implants with and without acrylonitrile O-ring. Indian J Dent Res 2012;23:840-1.
  51. Tanino F, Hayakawa I, Hirano S, Minakuchi S. Finite element analysis of stress-breaking attachments on maxillary implantretained overdentures. Int J Prosthodont 2007;20:193-8.
  52. Geering AH, Kundert M. Total-und hybridprothetik. Stuttgart: Thieme Verlag, 1986.
  53. Budtz-Jorgensen E. Prosthodontics for the elderly. Diagnosis and treatment. Chicago: Quintessence, 1999.
  54. Anusavice KJ, Shen Ch, Rawls HR. Phillips' science of dental materials. St. Louis: Elsevier; 2013. p. 365-95.
  55. Petrie CS, Walker MP, Lu Y, Thiagarajan G. A preliminary three-dimensional finite element analysis of mandibular implant overdentures. Int J Prosthodont 2014;27:70-2. https://doi.org/10.11607/ijp.3425

Cited by

  1. Balanced occlusion aided locator abutment retained overdenture with no implant placed within anterior region: A case report vol.6, pp.8, 2018, https://doi.org/10.1002/ccr3.1606
  2. Five‐year study of mandibular overdentures on stud abutments: Clinical outcome, patient satisfaction and prosthetic maintenance—Influence of bone resorption and implant position vol.30, pp.9, 2017, https://doi.org/10.1111/clr.13501
  3. Current evidence for IOD and IARPD vol.13, pp.3, 2017, https://doi.org/10.2186/ajps.13.187