DOI QR코드

DOI QR Code

Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy

전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구

  • Received : 2017.08.23
  • Accepted : 20170931
  • Published : 2018.12.01

Abstract

The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

Keywords

References

  1. KRNA Report "Estimated Report for railway electricrization In 2017".
  2. KRSA-3010-R2 Fault Localization device
  3. KRNA Report "Metropolitan Express train (Suseo) electric railway power supply equipment project report," 2012 pp. 22-25)
  4. Jung-Chul Kim "Feeder system for Electric railway and protection," Gidari publisher, pp.202-214, 2004.
  5. Yang-Su Kim, Hae-Chul Yu, "Electric Railway Engineering," dongil publisher, pp.105-105,2009.
  6. Sam-Hong parkl, Hae-Chul Yu, "Electric Railway Professional Engineer", dongil publisher, pp. 17-23, 2010.
  7. KRNA Report "Technology on the electric railway feeder protection system using forward and revers impedance," pp. 17-23, 2011
  8. KRNA Report "Railway design guide and handbook", KR E-02090, pp. 79-92, 2014.
  9. KRNA Electric operation data book pp. 38-39. 2017.