DOI QR코드

DOI QR Code

Analysis of Power Generation Characteristics according to the MPPT Algorithm Period

MPPT 알고리즘의 주기에 따른 발전 영향 분석

  • Min, Joonki (Dept. of Electrical System Engineering, Hanbat National University) ;
  • Choi, Wonseok (Dept. of Electrical Engineering, Hanbat National University)
  • Received : 2018.11.09
  • Accepted : 2018.11.23
  • Published : 2018.12.01

Abstract

In this paper, we compared power generation characteristics of two MPPT algorithms, P & O and InC, applied to grid-connected solar inverters. The MPPT detects the voltage and current of the solar module string and transfers the power to the DC link. Since the grid is connected by the power conversion circuit, the grid connection control and the MPPT control influence each other. The power generation characteristics were analyzed by Psim simulation according to the MPPT cycle in the weak grid conditions.

Keywords

References

  1. Yi Huang, Jin Wang, Fang Z. Peng, Dong-wook Yoo, "Survey of the Power Conditioning System for PV Power Generation," Power Electronics Specialists Conference, PESC '06, 37th IEEE, pp. 1-6, June 2006.
  2. Yeong-Sik Choe, Eun-Gyeong Kim, Jin-U Jeong, "MPPT Control Technique of PV System," Journal of the Korean Institute of Power Electronics, vol. 18, no. 1, pp. 29-36, Feb. 2013.
  3. Hyun-Woo Seo, Jung-Min Kwon, Bong-Hwan Kwon, "Transformerless Three-Phase Line-connected Photovoltaic PCS," Journal of the Korean Institute of Power Electronics, vol. 12, no. 5, pp. 355-363, Feb. 2007.
  4. Jiajun Ding, Jongmin Jo, Jungsub Lee, Hanju Cha, "A Study on High-Efficiency MPPT Algorithm Based on P&O Method with Variable Step Size," Proceedings of The Korean Institute of Power Electronics 2018 Sumemer Conference, pp. 120-122, July 2018.
  5. IEC/TR 60725, Consideration of reference impedance and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ${\leq}75$ A per phase.
  6. Soren Lund Lorenzen, Alex Buus Nielsen, and Lorand Bede, "Control of a grind connected converter during weak grid conditions," 2016 IEEE 7th International Symposium on Power Electroncis for Distributed Generation Systems(PEDG), pp. 1-6, Jun. 2016.