Abstract

The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

Keywords

References

  1. Kim, K. H., Lee, K. Y., and Park, J. S., 2015, A study on the current status and improvement in performing flush-out in muti-family residential buildings, Korean Journal of The Architectural Institute, Vol. 31, pp. 129-134.
  2. Lee, K. Y., Kim, K. H., and Park, J. S., 2016, Study of energy cost for performing flush-out in newly constructed multi-residential buildings during winter season, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 28, pp. 110-114. https://doi.org/10.6110/KJACR.2016.28.3.110
  3. Yoo, B. H., Park, Y. S., and Cho, H., 2005, Reduction Effect on Chemical Substance in Indoor Air Pollution Using Bake-out, Proceedings of the AIK 2005 Annual Conference, Vol. 25, No. 1, pp. 83-86.
  4. Park, E. Y., Kang, D. H., Choi, D. H., Sung, M. K., Yeo, M. S., and Kim, K. W., 2006, An Experimental Study on Bake-Out of New Apartment Buildings in Summer, Proceeding of the SAREK 2006 Winter Annual Conference, pp. 138-143.
  5. Yoo, B. H., 2007, A Study on Reduction Effect of Chemical Substances on Different Methods of Bake Out in New Apartment in Summer, Korean Journal of The Architectural Institute, Vol. 23, No. 9, pp. 163-171.
  6. Jo, W. J. and Sohn, J. Y., 2008, The Effect of Bake-out Conditions on Indoor Air Quality, Korean Journal of The Architectural Institute, Vol. 24, No. 9, pp. 295-302.