DOI QR코드

DOI QR Code

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea

창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가

  • Lim, Hee Won (Department of Architectural Engineering, Daejeon University) ;
  • Kim, Dong Yun (Department of Architectural Engineering, Daejeon University) ;
  • Lee, Soo Man (Department of Architectural Engineering, Daejeon University) ;
  • An, Jung Hyuk (Eagon Window & Door) ;
  • Yoon, Jong Ho (Department of Architectural Engineering, Hanbat University) ;
  • Shin, U Cheul (Department of Architectural Engineering, Daejeon University)
  • Received : 2017.12.14
  • Accepted : 2018.02.09
  • Published : 2018.04.10

Abstract

The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Kim, D. Y., Lim, H. W., and Shin, U. C., 2016, A Study on the Window Energy Rating Systems in Residential Buildings, The International Journal of The Korea Institute of Ecological Architecture and Environment, Vol. 16, No. 2, pp. 33-41.
  2. Grynning, S., Gustavsen, A., Time, B., and Jelle, B. P., 2013, Winodws in the buildings of tomorrow : Energy losers or energy gainers?, Energy and Building, Vol. 61, pp. 185-192. https://doi.org/10.1016/j.enbuild.2013.02.029
  3. Park, J. I., 2010, A study of Energy use Impacts by SHGCs of Windows in Detached House, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 22, No. 4, pp. 189-196.
  4. Yoon, Y. S., Yoon, J. H., Hyun, J. H., Hwang, W. J., Shin, J. G., Choi, W. K., and Mun, S. H., 2012, A Study on the Optimal Glazing Units in Apartment-Focused on the Glazing Performance and Heating/Cooling Setpoint Temperature, Journal of the Architectural Institute of Korea Planning & Design, Vol. 28, No. 10, pp. 301-308. https://doi.org/10.5659/JAIK_PD.2012.28.10.301
  5. Choi, M. S. and Chang, S. J., 2013, Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions, The International Journal of The Korea Institute of Ecological Architecture and Environment, Vol. 13, No. 2, pp. 123-130. https://doi.org/10.12813/kieae.2013.13.2.123
  6. Kwak, H. J., Hang, H. I., Lee, H. S., Eom, J. Y., and Suh, S. J., 2013, Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25, No. 6, pp. 338-345. https://doi.org/10.6110/KJACR.2013.25.6.338
  7. Lee, N. E., Ahn, B. L., Jeong, H. G., Kim, J. H., and Jang, C. Y., 2013, Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio, Journal of the Korea Institute of Ecological Architecture and Environment, Vol. 13, No. 3, pp. 71-78. https://doi.org/10.12813/kieae.2013.13.3.071
  8. http://kosis.kr/statHtml/statHtml.do?orgId=388&tblId=TX_38802_A003.
  9. http://www.srd.re.kr/db/srdDataInfoView.do?scid=S06001003&sdid=2.