DOI QR코드

DOI QR Code

A Study on the Estimation of Blood Pressure Based on the Magneto-Plethysmography for Smart Healthcare

스마트 헬스케어를 위한 자계용적맥파 기반 혈압 추정에 관한 연구

  • Lee, Seong-Su (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Lee, Kang-Hwi (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Kim, Sang-Min (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Lee, Hyeok-Jae (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Lee, Byoung-Hun (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Kim, Kyeoung-Seop (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University) ;
  • Lee, Jeong-Whan (College of Science & Technology, Dept. of Biomedical Engineering, Konkuk University)
  • Received : 2018.05.31
  • Accepted : 2018.06.25
  • Published : 2018.07.01

Abstract

High blood pressure causes various cardiovascular diseases and is associated with mortality. Periodic self-monitoring and recording of blood pressure is very helpful in preventing the occurrence of secondary diseases caused by hypertension. However, existing cuff-type blood pressure monitors have many limitations. As an alternative of that, a method of estimating the blood pressure by measuring the velocity change of the blood flow using the photo plethysmography is widely known. However, photo plethysmography have a low correlation with blood flow. So, we will propose an algorithm for estimating blood pressure using the relationship between velocity change of blood flow measured by magnetic field instead of photo plethysmography and electrocardiogram. For this purpose, First, we analyzed the correlation between photo plethysmography and magneto plethysmography. the correlation between MPG and PPG was r = 0.9449. Second, we compared estimated blood pressure and measured blood pressure. In the four experiment each result was r = 0.5737, r = 0.7863, r = 0.5669, and r = 0.7445.

Keywords

References

  1. "Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies", The Lancet, vol. 360, no. 9349, pp. 1903-1913, Dec. 2002. https://doi.org/10.1016/S0140-6736(02)11911-8
  2. T. Ohkubo et al., "Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement: a populationbased observation in Ohasama, Japan", p. 5.
  3. J. I. Davies and A. D. Struthers, "Pulse wave analysis and pulse wave velocity: a critical review of their strengths and weaknesses", p. 10.
  4. H. Gesche, D. Grosskurth, G. Kuchler, and A. Patzak, "Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method", European Journal of Applied Physiology, vol. 112, no. 1, pp. 309-315, Jan. 2012. https://doi.org/10.1007/s00421-011-1983-3
  5. T. WIBMER et al., "Pulse Transit Time and Blood Pressure During Cardiopulmonary Exercise Tests", vol. 63, p. 10, 2014.
  6. J. Padilla, E. Berjano, J. Saiz, L. Facila, P. Diaz, and S. Merce, "Assessment of Relationships between Blood Pressure, Pulse Wave Velocity and Digital Volume Pulse", p. 4.
  7. Y.-J. Lee et al., "Magneto-Plethysmographic Sensor for Peripheral Blood Flow Velocity", IEEE Sensors Journal, vol. 14, no. 5, pp. 1341-1342, May 2014. https://doi.org/10.1109/JSEN.2014.2304752
  8. D. M. IC, N. A. P. ELJ, and F. X. HART, "ELECTRIC PROPERTIES OF TISSUES", p. 12.
  9. R. Pethig and D. B. Kell, "The passive electrical properties of biological systems: their significance in physiology, biophysics and biotechnology", Physics in Medicine and Biology, vol. 32, no. 8, pp. 933-970, Aug. 1987. https://doi.org/10.1088/0031-9155/32/8/001
  10. "Photoplethysmogram", , (Access Date 2018.05.02.).