DOI QR코드

DOI QR Code

Application of Wiener filter to Chest CR images

흉부 CR영상에 대한 위너필터의 적용

  • Choi, Seokyoon (Department of Radiological Science, Catholic University of Pusan)
  • 최석윤 (부산가톨릭대학교 방사선학과)
  • Received : 2018.08.23
  • Accepted : 2018.08.31
  • Published : 2018.08.31

Abstract

Chest examinations and mass chest examinations using the CR(computed radiography) System are frequently used clinically. a factor that degrades image quality in the acquisition process is the use of unused IPs long times. this paper addresses the estimation of winer filter and improved wiener filter to restoration of Chest CR images Experimental results show that the proposed method can reduce noise. in low noise variation image wiener method was excellent than improved method and the result was the opposite at high noise varience. the application of algorithms to chest CR images effectively eliminates noise. the classic Wiener filter was better than the improved method. Multiple patients examined during the process without any erase IP(image plate) process, The proposed algorithm determines that the images can be restored to a good quality and will help to read the images.

CR시스템을 이용한 흉부검사 및 집단 흉부검사는 임상에서 자주 이용되고 있다. 흉부영상 획득과정에서 영상의 품질을 저하시키는 요인은 노후된 IP의 사용과 장시간 방치된 IP를 사용할 때이고 보관 시간에 노이즈가 대량 발생한다. 연구에서는 화질의 복원을 위해서 본 연구에서는 직접적인 계산방법인 위너필터와 개선된 위너필터를 적용하고 평가하였다. 실험결과 잡음의 변동이 작은 곳에서는 wiener의 방법이 우수하였고 잡음의 변동이 큰 곳에서는 개선된 방법이 우수하였다. 3일간 CR판독기로 잠상처리 않은 IP를 사용시 흉부CR 영상에 대해서 알고리즘 적용한 결과 잡음은 효과적으로 제거되었다 개선된 방법보다 고전적인 위너필터의 결과가 좋았다. CR영상 프로세스 과정에서 잠상처리를 하지 않고 다수의 환자를 검사했을 경우 제안한 알고리즘은 좋은 화질의 영상으로 복원가능하고 영상판독에 도움을 줄 것으로 판단한다.

Keywords

References

  1. W. J. Yu, S. H. Kang, Y. G. Lee, Y. Lee, "Study on Analysis of Noise Characteristics and Improvement Effectiveness using combination of two filters with Various Exposure Parameters based on Digital X-ray Imaging System", JIEIE, Vol. 55, No. 1, pp. 127-131, 2018.
  2. B. Y. Lim, H. S. Park, J. H. Kim, H. J. Kim, "Evaluation of Unexposed Images after Erasure of Image Plate from CR System," Korean journal of medical physics, Vol. 20, No. 4, pp. 199-207, 2009.
  3. C. H. Shin, C. Y. Jung, "A Restoration of Degraded Medicine Images Based on Optimized Parametric Wiener Filter, JKIICE", Vol. 16, No. 5, pp. 1056-1063, 2012.
  4. S. Choi, I. C. Im, "Noise Changes in Image Plate," Journal of the Korean Society of Radiology, Vol. 12, No. 2, pp. 271-275, 2018.
  5. Jae S. Two-Dimensional Signal and Image Processing, Prentice Hall, pp. 538, 1990.
  6. R. C. Gonzalez, R. E. Woods, Digital Image Processing, 3rd Ed, Addison-Wesley Publishing, Company, Inc., pp. 353, 2008.