DOI QR코드

DOI QR Code

A Study on the Reliability and Validity of Measuring the Range of Motion of the Elbow Joint Using a Smartphone Application

  • Lee, Jun Cheol (Department of Physical Therapy, Kyungnam College of Information & Technology)
  • 투고 : 2018.06.16
  • 심사 : 2018.06.29
  • 발행 : 2018.08.31

초록

The purpose of this study was to assess the intra-tester and inter-tester reliability and validity of elbow flexion range of motion using a smart phone used by the general public. Thirty-one general people participated in this study. The range of motion in active elbow flexion was measured with a goniometer and smart phone over two times by two observers. The intra-taster and inter-tester reliability were evaluated using the intraclass correlation coefficient(ICC). The validity was measured by Pearson's correlation coefficient. The intra-observer reliability was good in all measured items ICC>0.900. The inter-observer reliability was high with ICC>0.806. All correlation coefficients of android app and goniometer were greater than 0.868 and showed a significant positive correlation (p<0.01). The range of motion measurement with a smart phone showed acceptable reliability. Therefore, using a smartphone to measure the range of motion of the elbow joint could provide convenience and economic benefits.

키워드

참고문헌

  1. Lea RD, Gerhardt JJ. Range-of-motion measurements. J Bone Joint Surg Am. 1995;77(5):784-98. https://doi.org/10.2106/00004623-199505000-00017
  2. Jung MG, Im NY, Choi YC, Hwang JH, Cho AY, Choo YG, Oh TY. Reliability and Validity of internal Rotation and External Rotation of Shoulder Joint Using Smart Phone and Goniometer. J Korea Society for Neurotheapy. Vol. 20, No 2, :53-64, 2016. DOI: https://doi.org/Neurotherapy 2016.20,2,53
  3. Shin SH, Ro DH, Lee OS, Oh JH, Kim SH. Within-day reliability of shoulder range of motion measurement with a smartphone. Man Ther, Vol. 17, No 4, 298-304, 2012. DOI: https://doi.org/Elsevier.com/math.2012.17.4.304, https://doi.org/10.1016/j.math.2012.02.010
  4. Walter R, Kosy JD, Cove R. Inter- and intra-ob-server reliability of a smartphone application for measuring elbow angle. Vol. 19, No. 1, 18-2, 2013. https://doi.org/10.1016/j.fas.2012.08.004
  5. Pique-Vidal C, Maled-Garcia I, Arabi-Moreno J. Radiographic angles elbow : Differences between measurements made manually and with a computerized program. Int. Vol. 27, No. 3, 175-180., 2016.
  6. Nix S, Russell T, Vicenzino B. Validity and reliability of elbow angle measured on digital photographs. J Orthop Sports Phys Ther. Vol. 42, No. 7, 642-648, 2012. https://doi.org/10.2519/jospt.2012.3841
  7. De Winter AF, Heemskerk MA, Terwee CB. Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. BMC Musculoskelet Disord. Vol. 14, No. 5, 18, 2004. DOI: https://doi.org/biomedcentral.com/1471-24,4/5/18
  8. Green S, Buchbinder R, Forbes A, A standardized protocol for measurement of range of movement of the shoulder using the Plurimeter-V inclinometer and assessment of its intra-rater and inter-rater reliability. Arthritis Care Res. Vol. 1, No. 1, 43-52., 1998. DOI: https://doi.org/0893-7524198
  9. Kolber MJ, Vega F, Widmayer K, Cheng MS. The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer. Physiother Theory Pract. Vo. 2, No. 2, 176-84, 2011. DOI: https://doi.org/10.3109/095939.858,2010.481011
  10. Hoving JL, Buchbinder R, Green S, Forbes A, Bellamy N, Brand C, Buchanan R, Hall S, Patrick M, Ryan P. How reliably do rheumatologists measure shoulder movement? Ann Rheum Dis. Vol. 6, No. 7, 612-6, 2002. DOI: https://doi.org/lard.bmj.com
  11. Portney LG, Watkins MP. Foundations of clinical research: Applications to Practive(2nd ed). NewJersey. Prentice Hall. 2000.
  12. Jeon IC, Kwon OY, Weon JY, Ha SM, Kim SH. Reliability and validity of measurement using smartphone based goniometer of tibial external rotation angle in standing knee flexion. Physical Therapy Korea. Vol. 20, No. 2, 60-68, 2013. DOI: https://doi.org/10.12674/ptk.2013.20.2.060
  13. Wang L, Hu J, Li F. Advances in the application of smart phones in modern medicine. J Biomedcial Engineering-Chengdu-. Vol. . 3, No. 4, 222-227, 2014.
  14. Srivastava S, Chockalingam N, El Fakhri T. Radiographic measurements of elbow angle: A review of current techniques. (Edinb). Vol. 20, No. 1, 27-31., 2010. DOI: https://doi.org/elsever.com/locate foot https://doi.org/10.1016/j.foot.2009.12.002
  15. Park SW, Kim MS, Bae PT, Cha YH. The Reliability and Validity of Hip Range of Motion Measurement using a phone Operative Patient, J Korean Soc Phys Med. Vol. 10, No. 2, 1-7, 2015. DOI: https://doi.org/10.13066/ks.-.2015.10.2.1
  16. Fermanian JDA. Top-down approach for asset-backed securities: A Consistent way of managing prepayment, default and interest rate risks. J Real Estate Finance and Economics. Vol. 46, No. 3, 480-515, 2013. DOI: https://doi.org/10.1007/ㄴ11146-011-9331-2
  17. Choung SD, Kang SK, Kim MS, Weon JH, Reliability and Validity of the Goniometer for Hallux Valgus Angle Measurement, Phys Ther Kor. Vol. 20, No. 2, 46-5, 2013. DOI: https://doi.org/100126741/ptk.2013.20.2.046 https://doi.org/10.12674/ptk.2013.20.2.046
  18. Juul-Kristensen B, Lund H, Hansen K, Christensen H, Danneskiold-Samso B, Bliddal H. Test-retest reliability of joint position and kin esthetic sense in the elbow of healthy subjects. Physiother Theory Pract. Vol. 24, No. 1, 65-72, 2008. DOI: https://doi.org/10.1080/09593980701378173
  19. Ockendon M, Gilbert RE. Validation of a novel smartphone accelerometer-based knee goniometer. J Knee Surg. Vol. 25, No. 4, 341-345, 2012. DOI: https://dx.doi.org/10.1055/s0031-1299669
  20. Han YS, Choi JK, Hwang BH, Go SM, Yoon SH, Ji YG. A study on elderly for improvement of usability on smartphone. J Soc e-Bus Stud. Vol. 17, No. 1, 39-52, 2012. DOI: https://doi.org/10.7838/jesbs.2012.17.039
  21. Jung SK. Research on synchronization between smart toys and smart phones for classifying smart toys. International Journal of Internet, Broadcasting and Communication. Vol. 9, NO. 4, 25-30, 2017. DOI: http://dx.doi.org/10.7236/IJIBC.2017.9.4.25