Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study

  • Kim, Sung-Jun (Department of Dentistry, Graduate School, Kyungpook National University) ;
  • Son, KeunBaDa (Department of Dental Science, Graduate School, Kyungpook National University) ;
  • Lee, Kyu-Bok (Department of Dentistry, Graduate School, Kyungpook National University)
  • Received : 2018.05.17
  • Accepted : 2018.08.28
  • Published : 2018.10.31

Abstract

PURPOSE. To measure axial displacement of different implant-abutment connection types and materials during screw tightening at the recommended torque by using a contact scanner for two-dimensional (2D) and three-dimensional (3D) analyses. MATERIALS AND METHODS. Twenty models of missing mandibular left second premolars were 3D-printed and implant fixtures were placed at the same position by using a surgical guide. External and internal fixtures were used. Three implant-abutment internal connection (INT) types and one implant-abutment external connection (EXT) type were prepared. Two of the INT types used titanium abutment and zirconia abutment; the other INT type was a customized abutment, fabricated by using a computer-controlled milling machine. The EXT type used titanium abutment. Screws were tightened at $10N{\cdot}cm$, simulating hand tightening, and then at the manufacturers' recommended torque ($30N{\cdot}cm$) 10 min later. Abutments and adjacent teeth were subsequently scanned with a contact scanner for 2D and 3D analyses using a 3D inspection software. RESULTS. Significant differences were observed in axial displacement according to the type of implant-abutment connection (P<.001). Vertical displacement of abutments was greater than overall displacement, and significant differences in vertical and overall displacement were observed among the four connection types (P<.05). CONCLUSION. Displacement according to connection type and material should be considered in choosing an implant abutment. When adjusting a prosthesis, tightening the screw at the manufacturers' recommended torque is advisable, rather than the level of hand tightening.

Keywords

References

  1. Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100. https://doi.org/10.3109/02844316909036699
  2. Brånemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410. https://doi.org/10.1016/S0022-3913(83)80101-2
  3. Branemark PI, Svensson B, van Steenberghe D. Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism. Clin Oral Implants Res 1995;6:227-31. https://doi.org/10.1034/j.1600-0501.1995.060405.x
  4. Sutter F, Weber HP, Sorensen J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodontic Restor Dent 1993;13:408-31.
  5. Ugurel CS, Steiner M, Isik-Ozkol G, Kutay O, Kern M. Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections. Clin Oral Implants Res 2015;26:137-42. https://doi.org/10.1111/clr.12303
  6. Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl 1977;16:1-132.
  7. Norton MR. An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design. Clin Oral Implants Res 1997;8:290-8. https://doi.org/10.1034/j.1600-0501.1997.080407.x
  8. Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. J Oral Rehabil 2006;33: 75-8. https://doi.org/10.1111/j.1365-2842.2006.01545.x
  9. Schwarz MS. Mechanical complications of dental implants. Clin Oral Implants Res 2000;11:156-8. https://doi.org/10.1034/j.1600-0501.2000.011S1156.x
  10. Dailey B, Jordan L, Blind O, Tavernier B. Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque. Int J Oral Maxillofac Implants 2009;24:251-6.
  11. Yilmaz B, Seidt JD, McGlumphy EA, Clelland NL. Displacement of screw-retained single crowns into implants with conical internal connections. Int J Oral Maxillofac Implants 2013;28: 803-6. https://doi.org/10.11607/jomi.3005
  12. Winkler S, Ring K, Ring JD, Boberick KG. Implant screw mechanics and the settling effect: overview. J Oral Implantol 2003;29:242-5. https://doi.org/10.1563/1548-1336(2003)029<0242:ISMATS>2.3.CO;2
  13. Lee JH, Kim DG, Park CJ, Cho LR. Axial displacements in external and internal implant-abutment connection. Clin Oral Implants Res 2014;25:e83-9. https://doi.org/10.1111/clr.12062
  14. Spector MR, Donovan TE, Nicholls JI. An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 1990;63:444-7. https://doi.org/10.1016/0022-3913(90)90235-5
  15. Liu DY, Cader FN, Abduo J, Palamara J. Accuracy of different implant impression techniques: Evaluation of new tray design concept. J Prosthodont 2017 Dec 29. doi: 10.1111/jopr.12733. [Epub ahead of print].
  16. Tan KB, Nicholls JI. The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint. Int J Oral Maxillofac Implants 2002;17:175-83.
  17. Dellinges MA, Tebrock OC. A measurement of torque values obtained with hand-held drivers in a simulated clinical setting. J Prosthodont 1993;2:212-4. https://doi.org/10.1111/j.1532-849X.1993.tb00411.x
  18. Kanawati A, Richards MW, Becker JJ, Monaco NE. Measurement of clinicians' ability to hand torque dental implant components. J Oral Implantol 2009;35:185-8. https://doi.org/10.1563/1548-1336-35.4.185
  19. Moon SJ, Kim HJ, Son MK, Chung CH. Sinking and fit of abutment of locking taper implant system. J Adv Prosthodont 2009;1:97-101. https://doi.org/10.4047/jap.2009.1.2.97
  20. Gilbert AB, Yilmaz B, Seidt JD, McGlumphy EA, Clelland NL, Chien HH. Three-Dimensional Displacement of Nine Different Abutments for an Implant with an Internal Hexagon Platform. Int J Oral Maxillofac Implants 2015;30: 781-8. https://doi.org/10.11607/jomi.3678
  21. Siadat H, Beyabanaki E, Mousavi N, Alikhasi M. Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections. J Adv Prosthodont 2017;9:271-7. https://doi.org/10.4047/jap.2017.9.4.271
  22. Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent 1999;81: 537-52. https://doi.org/10.1016/S0022-3913(99)70208-8
  23. Tagger Green N, Machtei EE, Horwitz J, Peled M. Fracture of dental implants: literature review and report of a case. Implant Dent 2002;11:137-43. https://doi.org/10.1097/00008505-200204000-00014
  24. Kim KS, Lim YJ, Kim MJ, Kwon HB, Yang JH, Lee JB, Yim SH. Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection. Clin Oral Implants Res 2011;22:834-9. https://doi.org/10.1111/j.1600-0501.2010.02063.x
  25. Shim HW, Yang BE. Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures. J Adv Prosthodont 2015; 7:423-30. https://doi.org/10.4047/jap.2015.7.6.423
  26. Messias A, Rocha S, Calha N, Neto MA, Nicolau P, Guerra F. Effect of intentional abutment disconnection on the micromovements of the implant-abutment assembly: a 3D digital image correlation analysis. Clin Oral Implants Res 2017;28:9- 16.
  27. Rebeeah HA, Yilmaz B, Seidt JD, McGlumphy E, Clelland N, Brantley W. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening. J Prosthet Dent 2018;119:132-7. https://doi.org/10.1016/j.prosdent.2017.02.025
  28. Schaefer O, Watts DC, Sigusch BW, Kuepper H, Guentsch A. Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility. Dent Mater 2012;28:320-6. https://doi.org/10.1016/j.dental.2011.12.008
  29. Rudolph H, Luthardt RG, Walter MH. Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology. Comput Biol Med 2007; 37:579-87. https://doi.org/10.1016/j.compbiomed.2006.05.006
  30. Rhee YK, Huh YH, Cho LR, Park CJ. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition. J Adv Prosthodont 2015;7: 460-7. https://doi.org/10.4047/jap.2015.7.6.460
  31. Park JM. Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form. J Adv Prosthodont 2016; 8:354-62. https://doi.org/10.4047/jap.2016.8.5.354
  32. Park HN, Lim YJ, Yi WJ, Han JS, Lee SP. A comparison of the accuracy of intraoral scanners using an intraoral environment simulator. J Adv Prosthodont 2018;10:58-64. https://doi.org/10.4047/jap.2018.10.1.58
  33. Hayama H, Fueki K, Wadachi J, Wakabayashi N. Trueness and precision of digital impressions obtained using an intra-oral scanner with different head size in the partially edentulous mandible. J Prosthodont Res 2018;62:347-52. https://doi.org/10.1016/j.jpor.2018.01.003
  34. Patzelt SB, Emmanouilidi A, Stampf S, Strub JR, Att W. Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig 2014;18:1687-94. https://doi.org/10.1007/s00784-013-1132-y
  35. Persson A, Andersson M, Oden A, Sandborgh-Englund G. A three-dimensional evaluation of a laser scanner and a touchprobe scanner. J Prosthet Dent 2006;95:194-200. https://doi.org/10.1016/j.prosdent.2006.01.003
  36. Dimitrova M. A 3D evaluation of the repeatability of accuracy in optical and contact scanners. Doctor's Thesis, Cardiff Metropolitan University, Cardiff, Wales, UK; 2017. p. 1-36.

Cited by

  1. Displacement of Customized Abutments Designed on a Working Cast and in the Oral Cavity: A Comparative In Vivo Study vol.29, pp.1, 2018, https://doi.org/10.1111/jopr.13120
  2. Clinical and laboratory passive fit assessment of implant‐supported zirconia restorations fabricated using conventional and digital workflow vol.22, pp.2, 2018, https://doi.org/10.1111/cid.12885
  3. 임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고 vol.59, pp.1, 2021, https://doi.org/10.4047/jkap.2021.59.1.126
  4. Accuracy of Proximal and Occlusal Contacts of Single Implant Crowns Fabricated Using Different Digital Scan Methods: An In Vitro Study vol.14, pp.11, 2018, https://doi.org/10.3390/ma14112843