DOI QR코드

DOI QR Code

Dose Assessment According to Application of Carbon Fabric Blanket During Radiation Therapy of the Spine Metastasis Cancer

척추 전이암 환자의 방사선치료 시 Carbon Fabric Blanket 적용에 따른 선량평가

  • Yang, Myung-Sic (Department of Radiation Oncology, Chonbuk National University Hospital) ;
  • Kim, Jung-Soo (Department of Radiation Oncology, Institute for Medical Sciences, Chonbuk National University Medical School) ;
  • Lee, Sun-Young (Department of Radiation Oncology, Institute for Medical Sciences, Chonbuk National University Medical School) ;
  • Kwon, Hyoung-Cheol (Department of Radiation Oncology, Institute for Medical Sciences, Chonbuk National University Medical School)
  • 양명식 (전북대학교병원 방사선종양학과) ;
  • 김정수 (전북대학교 의과대학 방사선종양학과) ;
  • 이선영 (전북대학교 의과대학 방사선종양학과) ;
  • 권형철 (전북대학교 의과대학 방사선종양학과)
  • Received : 2019.01.07
  • Accepted : 2019.02.25
  • Published : 2019.02.28

Abstract

The purpose of this study was to improve the unstable treatment posture by placing the Carbon fabric blanket on the couch which was used for the patient fixation for the unstable posture from the severe pain caused by the neuromuscular pressure of the spinal metastatic cancer patient and to analyze the dose difference caused by the energy loss of high energy radiation. Using a linear accelerator, a FC-65G was installed at a depth of 5 cm at a solid phantom at 6 MV and 10 MV energies. The SAD was 100 cm, Gantry angle was $0^{\circ}$, a Cotton and Carbon blanket with a thickness of 1 cm on the couch, The blankets were placed on the couch and the dose was measured according to field size. For the dose measurement, and the dose was measured at 100 MU each time, and the mean value was calculated by repeating the measurement three times in order to reduce the error. The results showed that the difference rate in dose between Carbon blanket and Cotton blanket was respectively -0.54% and -0.75% based on the absence of the blanket(Non). Therefore, it is considered that the use of Carbon fabric blanket, which reduces the patient's pain and does not affect the depth dose, may be useful during radiation therapy of the spine metastasis cancer.

Keywords

References

  1. Cobb CA, Leavens ME, Eckles N. Indications for nonoperative treatment of spinal cord compression due to breast cancer. J Neurosurg. 1977;47:653-8. https://doi.org/10.3171/jns.1977.47.5.0653
  2. Wong DA, Fornasier VL, MacNab I. Spinal metastases: the obvious, the occult, and the impostors. Spine. 1990;15:1-4. https://doi.org/10.1097/00007632-199001000-00001
  3. Sohn SK, Kim JD, Lee JC, Hon YK. Collective review of cases of spinal metastases. the korean orthopaedic association. 1988;23(4):1087-96. https://doi.org/10.4055/jkoa.1988.23.4.1087
  4. Woo YK, Rhee SK, Kim HM, Kang YK, Song SW, Bahk WJ, et al. Surgical treatment of metastatic tumor of spine musculoskeletal oncology study group. Journal of Korea Orthop Assoc. 1993;28(5):1774-82. https://doi.org/10.4055/jkoa.1993.28.5.1774
  5. Cho KC, Kim JH, Kim HK, Ahn SK, Lee SK, Yoon JW, et al. Clinical Application Analysis of 3D-CRT Methods Using Tomotherapy. The Korean Journal of Radiological Science and Technology. 2013;36(4):327-35.
  6. Kim YY, Bang SJ, Jung S, Kim JS, Kim YK. Evaluation of the efficiency of the vac-lock type belly board in pelvic cancer radiation treatment. Korean Society for Radiation Therapy. 2013;26(1):37-42.
  7. Je JY, Park CW, Noh KS. Measurement of Skin Dose from Using the Treatment Immobilization Devices. The Korean Journal of Radiological Science and Technology. 2009;32(1):107-10.
  8. Gerlich AS, Van der Velden JM, Fanetti G, Zoetelief A, Eppinga WSC, Seravalli E. The immobilizing effect of the vacuum cushion in spinal SBRT and the impact of pain. Radiotherapy & Oncology. 2017;123(1):876-7. https://doi.org/10.1016/S0167-8140(17)32055-8
  9. IAEA Technical report series no. 398: Absorbed dose determination in external beam radiotherapy. An international code of practice for dosimetry based on standards of absorbed dose to water. International atomic energy agency. 2000. https://www-pub.iaea.org/books/IAEABooks/5954/Absorbed-Dose-Determination-in-External-Beam-Radiotherapy.
  10. Jaffe H. Tumors and tumorous conditions of the bones and joints. Philadelphia, Lea & Febiger. 1958:589-613.
  11. Black P. Spinal metastases: current status and recommended guidelines for management. Neurosurgery. 1979;5:726-46. https://doi.org/10.1227/00006123-197912000-00016
  12. Helweg-Larsen S. Clinical outcome in metastatic spinal cord compression: a prospective study of 153 patients. Acta Neurol Scand. 1996;94:269-75. https://doi.org/10.1111/j.1600-0404.1996.tb07064.x
  13. Kim NH, Lee HM, Kim HJ, Chung IH, Kim SJ. Morphometric study of the pedicles of thoracic and lumbar vertebrae in Korea. J. of Korean Orthop. Assoc. 1990;25(4):1199-207. https://doi.org/10.4055/jkoa.1990.25.4.1199
  14. De Mooy LG. The use of carbon fibers in radiotherapy. Radiother Oncology. 1991;22(2):140-2. https://doi.org/10.1016/0167-8140(91)90010-E
  15. Seo MK, Choi KE, Min BG, Park SJ. Carbon fibers: General understanding and manufacturing techniques of carbon fibers. Carbon letters. 2008;9(3): 218-31. https://doi.org/10.5714/CL.2008.9.3.218
  16. Chie EK, Park JP, Huh SN, Hong SM, Park SW, Kim IA, et al. Carbon fiber as material for radiation fixation device: A comparative study with acrylic, J. Korea Asso. Radiat. Prot. 2005;30(1):1-7.
  17. Meara SJ, Langmack KA. An investigation into the use of carbon fibre for megavoltage radiotherapy applications. Phys Med Biol. 1998;43(5):1359-66. https://doi.org/10.1088/0031-9155/43/5/025
  18. KenjiMyint W. Investigating treatment dose error due to beam attenuation by a carbon fiber tabletop. Medical Physics. 2006;3(7):21-7.
  19. Kim KW, Kim YG, Cho MJ, Kim JS, Oh YK, Kim JK, et al. Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film. Korean Society of Medical Physics. 2006;17(1):1-5.
  20. Olch J, Gerig L, Li H, Mihaylov L, Morgan A. Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Gruop 17. Medical Physics. 2014;41(6):1-30. https://doi.org/10.1118/1.4887907
  21. Brahme A. Dosimetric precision requirements in radiation therapy. Acta Radiol. Oncology. 1984;23:379-91. https://doi.org/10.3109/02841868409136037
  22. Bentzen S. High thech in radiation oncology: should there be a ceiling?. Int, J. Radiat. Oncol. Biol. Phys. 2004;58:320-30. https://doi.org/10.1016/j.ijrobp.2003.09.057
  23. Mijnheer BJ, Battermann JJ, Wambersie A. What degree of accuracy is required and can be achieved in photonand neutron therapy?. Radiother Oncol. 1987;8(3):237-52. https://doi.org/10.1016/S0167-8140(87)80247-5
  24. Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R, et al. AAPM's TG-51 protocol for clinical reference dosimetry of high energy photon and electron beams. Med. Phys. 1999;26:1847-70. https://doi.org/10.1118/1.598691