DOI QR코드

DOI QR Code

Effect of polishing methods on color change by water absorption in several composite resins

여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향

  • Kim, Hye Jin (Department of Conservative Dentistry, Veterans Health Service Medical Center) ;
  • Kim, Mi-yeon (Department of Conservative Dentistry, Veterans Health Service Medical Center) ;
  • Song, Byung-chul (Department of Conservative Dentistry, Veterans Health Service Medical Center) ;
  • Kim, Sun-ho (Department of Conservative Dentistry, Veterans Health Service Medical Center) ;
  • Kim, Jeong-hee (Department of Conservative Dentistry, Veterans Health Service Medical Center)
  • 김혜진 (한국보훈복지공단 중앙보훈병원 치과보존과) ;
  • 김미연 (한국보훈복지공단 중앙보훈병원 치과보존과) ;
  • 송병철 (한국보훈복지공단 중앙보훈병원 치과보존과) ;
  • 김선호 (한국보훈복지공단 중앙보훈병원 치과보존과) ;
  • 김정희 (한국보훈복지공단 중앙보훈병원 치과보존과)
  • Received : 2018.08.18
  • Accepted : 2018.12.03
  • Published : 2019.03.30

Abstract

Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

목적: 복합레진의 색조안정성에 있어서 연마가 영향을 주는지 알아보았다. 연구 재료 및 방법: 2 개의 벌크필 레진과 4개의 복합레진을 6 mm 너비, 4 mm 높이로 제작하여 광중합한 후 $34^{\circ}C$ 멸균 증류수에 24 시간 보관하고 분광광도계를 이용하여 CIE $L^*a^*b^*$ 값을 측정하였다. 시편을 연마 방법에 따라 대조군(Mylar strip 그룹), PoGo로 연마한 그룹, Sof-Lex Spiral wheels로 연마한 그룹으로 나누었다(n = 5). 색측정은 4 주 동안 매주 시행하였고 실험 기간 동안 시편은 $34^{\circ}C$ 멸균증류수에 보관하였다. 실험결과는 일반최소자승법으로 통계분석하였다(P < 0.05). 결과: 일반최소자승법 분석에 따르면 Sof-Lex Spiral wheels로 연마한 그룹의 ${\Delta}E$ 값이 PoGo로 연마한 그룹과 대조군의 ${\Delta}E$ 값보다 낮게 나타났다(P < 0.05). 복합레진을 연마한 그룹의 ${\Delta}E$ 값은 연마하지 않은 대조군의 ${\Delta}E$ 값보다 낮게 나타났다(P < 0.05). 복합레진 비교시 Filtek Z250과 Filtek Z350 XT Universal restorative는 모든 기간에서 통계적 차이가 나타나지 않았으며 Tetric N-Ceram Bulk Fill은 1, 2, 3주에서 통계적으로 낮은 ${\Delta}E$ 값을 나타냈다(P < 0.05). 결론: 이번 연구의 한계점을 감안하면 연마 방법은 복합레진의 색조안정성에 영향을 미친다. Sof-Lex Spiral wheels로 연마한 그룹이 PoGo로 연마한 그룹보다 변색에 더 큰 저항을 보여주었다.

Keywords

References

  1. Schmitt VL, Puppin-Rontani RM, Naufel FS, Nahsan FP, Alexandre Coelho Sinhoreti M, Baseggio W. Effect of the polishing procedures on color stability and surface roughness of composite resins. ISRN Dent 2011;2011:617672.
  2. Douglas WH, Craig RG. Resistance to extrinsic stains by hydrophobic composite resin systems. J Dent Res 1982;61:41-3. https://doi.org/10.1177/00220345820610010901
  3. Shamszadeh S, Sheikh-Al-Eslamian SM, Hasani E, Abrandabadi AN, Panahandeh N. Color Stability of the Bulk-Fill Composite Resins with Different Thickness in Response to Coffee/Water Immersion. Int J Dent 2016;2016:7186140.
  4. Rueggeberg FA, Margeson DH. The effect of oxygen inhibition on an unfilled/filled composite system. J Dent Res 1990;69:1652-8. https://doi.org/10.1177/00220345900690100501
  5. Attar N. The effect of finishing and polishing procedures on the surface roughness of composite resin materials. J Contemp Dent Pract 2007;8:27-35. https://doi.org/10.5005/jcdp-8-1-27
  6. Patel B, Chhabra N, Jain D. Effect of different polishing systems on the surface roughness of nanohybrid composites. J Conserv Dent 2016;19:37-40. https://doi.org/10.4103/0972-0707.173192
  7. Kritzinger D, Brandt PD, De Wet FA. The effect of different polishing systems on the surface roughness of a nanocomposite and a microhybrid composite. SADJ 2017;72:249-57.
  8. Munteanu B, Andrian S, Ursu L, Stoleriu S, Iovan G, Ghiorghe CA. Evaluation of surface condition after finishing and polishing of a flowable composite material. Int J Med Dent 2016;6:124-9.
  9. Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 2013;38:618-25. https://doi.org/10.2341/12-395-L
  10. Bucuta S, Ilie N. Light transmittance and micromechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Investig 2014;18:1991-2000. https://doi.org/10.1007/s00784-013-1177-y
  11. Liberman R, Combe EC, Piddock V, Pawson C, Watts DC. Development and assessment of an objective method of colour change measurement for acrylic denture base resins. J Oral Rehabil 1995;22:445-9. https://doi.org/10.1111/j.1365-2842.1995.tb00799.x
  12. Ergucu Z, Turkun L, Aladag A. Color stability of nanocomposites polished with one-step systems. Oper Dent 2008;33:413-20. https://doi.org/10.2341/07-107
  13. Turkun LS, Turkun M. The effect of one-step polishing system on the surface roughness of three esthetic resin composite materials. Oper Dent 2004;29:203-11.
  14. Lu H, Roeder LB, Powers JM. Effect of polishing systems on the surface roughness of microhybrid composites. J Esthet Restor Dent 2003;15:297-304. https://doi.org/10.1111/j.1708-8240.2003.tb00300.x
  15. Venturini D, Cenci MS, Demarco FF, Camacho GB, Powers JM. Effect of polishing techniques and time on surface roughness, hardness and microleakage of resin composite restorations. Oper Dent 2006;31:11-7. https://doi.org/10.2341/04-155
  16. Sideridou I, Tserki V, Papanastasiou G. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins. Biomaterials 2003;24:655-65. https://doi.org/10.1016/S0142-9612(02)00380-0
  17. Choi MS, Lee YK, Lim BS, Rhee SH, Yang HC. Changes in surface characteristics of dental resin composites after polishing. J Mater Sci Mater Med 2005;16:347-53. https://doi.org/10.1007/s10856-005-0634-9
  18. Villalta P, Lu H, Okte Z, Garcia-Godoy F, Powers JM. Effects of staining and bleaching on color change of dental composite resins. J Prosthet Dent 2006;95:137-42. https://doi.org/10.1016/j.prosdent.2005.11.019
  19. Ertas E, Guler AU, Yucel AC, Koprulu H, Guler E. Color stability of resin composites after immersion in different drinks. Dent Mater J 2006;25:371-6. https://doi.org/10.4012/dmj.25.371
  20. Thumu J, Kadiyala A, Bollu IP, Ballullaya SV, Devalla S. Effect of Staining Solutions on the Color Stability of Conventional and Bulk Fill Nanohybrid Resin Composites: A Spectrophotometric Analysis. J Oper Dent Endod 2017;2:1-5.
  21. Buchalla W, Attin T, Hilgers RD, Hellwig E. The effect of water storage and light exposure on the color and translucency of a hybrid and a microfilled composite. J Prosthet Dent 2002;87:264-70. https://doi.org/10.1067/mpr.2002.121743
  22. Johnston WM, Kao EC. Assessment of appearance match by visual observation and clinical colorimetry. J Dent Res 1989;68:819-22. https://doi.org/10.1177/00220345890680051301
  23. Inokoshi S, Burrow MF, Kataumi M, Yamada T, Takatsu T. Opacity and color changes of tooth-colored restorative materials. Oper Dent 1996;21:73-80.
  24. Moore RJ, Watts JT, Hood JA, Burritt DJ. Intra-oral temperature variation over 24 hours. Eur J Orthod 1999;21:249-61. https://doi.org/10.1093/ejo/21.3.249