DOI QR코드

DOI QR Code

The Usefulness of a Wearable Device in Daily Physical Activity Monitoring for the Hospitalized Patients Undergoing Lumbar Surgery

  • Kim, Dong Hwan (Department of Neurosurgery & Medical Research Institue, Pusan National University Hospital, Pusan National University School of Medicine) ;
  • Nam, Kyoung Hyup (Department of Neurosurgery & Medical Research Institue, Pusan National University Hospital, Pusan National University School of Medicine) ;
  • Choi, Byung Kwan (Department of Neurosurgery & Medical Research Institue, Pusan National University Hospital, Pusan National University School of Medicine) ;
  • Han, In Ho (Department of Neurosurgery & Medical Research Institue, Pusan National University Hospital, Pusan National University School of Medicine) ;
  • Jeon, Tae Jin (SOOSANG ST Co., Inc.) ;
  • Park, Se Young (Department of Computer Science and Engineering, Pusan National University)
  • 투고 : 2018.06.15
  • 심사 : 2018.09.19
  • 발행 : 2019.09.01

초록

Objective : Functional outcomes have traditionally been evaluated and compared using subjective surveys, such as visual analog scores (VAS), the Oswestry disability index (ODI), and Short Form-36 (SF-36), to assess symptoms and quality of life. However, these surveys are limited by their subjective natures and inherent bias caused by differences in patient perceptions of symptoms. The Fitbit $Charge^{(R)}$ (Fitbit Inc., San Francisco, CA, USA) provides accurate and objective measures of physical activity. The use of this device in patients after laminectomy would provide objective physical measures that define ambulatory function, activity level, and degree of recovery. Therefore, the present study was conducted to identify relationships between the number of steps taken by patients per day and VAS pain scores, prognoses, and postoperative functional outcomes. Methods : We prospectively investigated 22 consecutive patients that underwent laminectomy for spinal stenosis or a herniated lumbar disc between June 2015 and April 2016 by the same surgeon. When patients were admitted for surgery and first visited after surgery, preoperative and postoperative functional scores were recorded using VAS scores, ODI scores, and SF-36. The VAS scores and physical activities were recorded daily from postoperative day (POD) 1 to POD 7. The relationship between daily VAS scores and daily physical activities were investigated by simple correlation analysis and the relationship between mean number of steps taken and ODI scores after surgery was subjected to simple regression analysis. In addition, Wilcoxon's signed-rank test was used to investigate the significance of pre-to-postoperative differences in VAS, ODI, and SF-36 scores. Results : Pre-to-postoperative VAS (p<0.001), ODI (p<0.001), SF-36 mental composite scores (p=0.009), and SF-36 physical composite scores (p<0.001) scores were found to be significantly different. Numbers of steps taken from POD 1 to POD 7 were negatively correlated with daily VAS scores (r=-0.981, p<0.001). In addition, the mean number of steps from POD 3 to POD 7 and the decrease in ODI conducted one month after surgery were statistically significant (p=0.029). Conclusion : Wearable devices are not only being used increasingly by consumers as lifestyle devices, but are also progressively being used in the medical area. This is the first study to demonstrate the usefulness of a wearable device for checking patient physical activity and predicting pain and prognosis after laminectomy. Based on our experience, the wearable device used to provide measures of physical activity in the present study has the potential to provide objective information on pain severity and prognosis.

키워드

참고문헌

  1. Adam Noah J, Spierer DK, Gu J, Bronner S : Comparison of steps and energy expenditure assessment in adults of Fitbit tracker and ultra to the actical and indirect calorimetry. J Med Eng Technol 37 : 456-462, 2013 https://doi.org/10.3109/03091902.2013.831135
  2. Berlin JE, Storti KL, Brach JS : Using activity monitors to measure physical activity in free-living conditions. Phys Ther 86 : 1137-1145, 2006 https://doi.org/10.1093/ptj/86.8.1137
  3. Cadmus-Bertram LA, Marcus BH, Patterson RE, Parker BA, Morey BL : Randomized trial of a Fitbit-based physical activity intervention for women. Am J Prev Med 49 : 414-418, 2015 https://doi.org/10.1016/j.amepre.2015.01.020
  4. Chapman JR, Norvell DC, Hermsmeyer JT, Bransford RJ, DeVine J, McGirt MJ, et al. : Evaluating common outcomes for measuring treatment success for chronic low back pain. Spine (Phila Pa 1976) 36(21 Suppl) : S54-S68, 2011 https://doi.org/10.1097/BRS.0b013e31822ef74d
  5. Chen KY, Bassett DR Jr : The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc 37(11 Suppl) : S490-S500, 2005 https://doi.org/10.1249/01.mss.0000185571.49104.82
  6. Culhane KM, O'Connor M, Lyons D, Lyons GM : Accelerometers in rehabilitation medicine for older adults. Age Ageing 34 : 556-560, 2005 https://doi.org/10.1093/ageing/afi192
  7. Diaz KM, Krupka DJ, Chang MJ, Peacock J, Ma Y, Goldsmith J, et al. : Fitbit(R): an accurate and reliable device for wireless physical activity tracking. Int J Cardiol 185 : 138-140, 2015 https://doi.org/10.1016/j.ijcard.2015.03.038
  8. Dimitrov DV : Medical internet of things and big data in healthcare. Healthc Inform Res 22 : 156-163, 2016 https://doi.org/10.4258/hir.2016.22.3.156
  9. Gershenfeld N, Krikorian R, Cohen D : The internet of things. Sci Am 291 : 76-81, 2004 https://doi.org/10.1038/scientificamerican1004-76
  10. Hao A, Wang L : Medical device integration model based on the internet of things. Open Biomed Eng J 9 : 256-261, 2015 https://doi.org/10.2174/1874120701509010256
  11. Iversen MD, Katz JN : Examination findings and self-reported walking capacity in patients with lumbar spinal stenosis. Phys Ther 81 : 1296-1306, 2001 https://doi.org/10.1093/ptj/81.7.1296
  12. Metcalf D, Milliard ST, Gomez M, Schwartz M : Wearables and the internet of things for health: wearable, interconnected devices promise more efficient and comprehensive health care. IEEE Pulse 7 : 35-39, 2016
  13. Mobbs RJ, Phan K, Maharaj M, Rao PJ : Physical activity measured with accelerometer and self-rated disability in lumbar spine surgery: a prospective study. Global Spine J 6 : 459-464, 2016 https://doi.org/10.1055/s-0035-1565259
  14. Noorkoiv M, Rodgers H, Price CI : Accelerometer measurement of upper extremity movement after stroke: a systematic review of clinical studies. J Neuroeng Rehabil 11 : 144, 2014 https://doi.org/10.1186/1743-0003-11-144
  15. Pantelopoulos A, Bourbakis NG : A survey on wearable sensor-based systems for health monitoring and prognosis. IEEE Trans Syst Man Cybern 40 : 1-12, 2010 https://doi.org/10.1109/TSMCB.2010.2051350
  16. Park S, Jayaraman S : Enhancing the quality of life through wearable technology. IEEE Trans Inf Technol Biomed 22 : 41-48, 2003
  17. Pryce R, Johnson M, Goytan M, Passmore S, Berrington N, Kriellaars D : Relationship between ambulatory performance and self-rated disability in patients with lumbar spinal stenosis. Spine (Phila Pa 1976) 37 : 1316-1323, 2012 https://doi.org/10.1097/BRS.0b013e31824a8314
  18. Scheer JK, Bakhsheshian J, Keefe MK, Lafage V, Bess S, Protopsaltis TS, et al. : Initial experience with real-time continuous physical activity monitoring in patients undergoing spine surgery. Clin Spine Surg 30 : E1434-E1443, 2017 https://doi.org/10.1097/BSD.0000000000000521
  19. Takacs J, Pollock CL, Guenther JR, Bahar M, Napier C, Hunt MA : Validation of the Fitbit one activity monitor device during treadmill walking. J Sci Med Sport 17 : 496-500, 2014 https://doi.org/10.1016/j.jsams.2013.10.241

피인용 문헌

  1. Internet of Things, Digital Biomarker, and Artificial Intelligence in Spine: Current and Future Perspectives vol.16, pp.4, 2019, https://doi.org/10.14245/ns.1938388.194
  2. Addressing Coronavirus Disease 2019 in Spine Surgery: A Rapid National Consensus Using the Delphi Method via Teleconference vol.14, pp.3, 2019, https://doi.org/10.31616/asj.2020.0224
  3. Assessment and Post-Intervention Recovery After Surgery for Lumbar Disk Herniation Based on Objective Gait Metrics from Wearable Devices Using the Gait Posture Index vol.142, 2019, https://doi.org/10.1016/j.wneu.2020.06.104
  4. Validation of a gyroscope-based wearable device for real-time position monitoring of patients in a hospital vol.29, pp.4, 2021, https://doi.org/10.3233/thc-202575