DOI QR코드

DOI QR Code

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min (Department of Plastic and Reconstructive Surgery, Nowon Eulji Medical Center, Eulji University School of Medicine) ;
  • Lee, Jong Hun (Department of Plastic and Reconstructive Surgery, Nowon Eulji Medical Center, Eulji University School of Medicine)
  • Received : 2019.08.27
  • Accepted : 2019.10.18
  • Published : 2019.10.20

Abstract

Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.

Keywords

References

  1. Tripathi N, Goyal M, Mishra B, Dhasmana S. Zygomatic complex fracture: a comparative evaluation of stability using titanium and bio-resorbable plates as one point fixation. Natl J Maxillofac Surg 2013;4:181-7. https://doi.org/10.4103/0975-5950.127648
  2. Al-Sukhun J, Lindqvist C. A comparative study of 2 implants used to repair inferior orbital wall bony defects: autogenous bone graft versus bioresorbable poly-L/DL-Lactide [P(L/DL) LA 70/30] plate. J Oral Maxillofac Surg 2006;64:1038-48. https://doi.org/10.1016/j.joms.2006.03.010
  3. Lionelli GT, Korentager RA. Biomechanical failure of metacarpal fracture resorbable plate fixation. Ann Plast Surg 2002;49:202-6. https://doi.org/10.1097/00000637-200208000-00015
  4. Waris E, Ashammakhi N, Kaarela O, Raatikainen T, Vasenius J. Use of bioabsorbable osteofixation devices in the hand. J Hand Surg Br 2004;29:590-8. https://doi.org/10.1016/J.JHSB.2004.02.005
  5. Yerit KC, Hainich S, Turhani D, Klug C, Wittwer G, Ockher M, et al. Stability of biodegradable implants in treatment of mandibular fractures. Plast Reconstr Surg 2005;115:1863-70. https://doi.org/10.1097/01.PRS.0000165075.51898.6F
  6. Uygur S, Cukurluoglu O, Ozmen S, Guclu TH, Sezgin B. Resorbable mesh plate in the treatment of blow-out fracture might cause gaze restriction. J Craniofac Surg 2009;20:71-2. https://doi.org/10.1097/SCS.0b013e318190dee0
  7. Bessho K, Iizuka T, Murakami K. A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery. J Oral Maxillofac Surg 1997;55:941-5. https://doi.org/10.1016/S0278-2391(97)90065-3
  8. Rameshbabu N, Rao KP, Kumar TSS. Acclerated microwave processing of nanocrystalline hydroxyapatite. J Mater Sci 2005;40:6319-23. https://doi.org/10.1007/s10853-005-2957-9
  9. Shikinami Y, Okuno M. Bioresorbable devices made of forged composites of hydroxyapatite (HA) particles and poly-L-lactide (PLLA): Part I. basic characteristics. Biomaterials 1999;20:859-77. https://doi.org/10.1016/S0142-9612(98)00241-5
  10. Shikinami Y, Matsusue Y, Nakamura T. The complete process of bioresorption and bone replacement using devices made of forged composites of raw hydroxyapatite particles/poly l-lactide (F-u-HA/PLLA). Biomaterials 2005;26:5542-51. https://doi.org/10.1016/j.biomaterials.2005.02.016
  11. Goto K, Akiyama H, Kawanabe K, So K, Nakamura T. Use of HA-plla composite screws to fix acetabular bone graft in cemented THA: absorption pattern of screws in six patients. Key Eng Mater 2011;493:422-25.
  12. Losken HW, van Aalst JA, Mooney MP, Godfrey VL, Burt T, Teotia S, et al. Biodegradation of Inion fast-absorbing biodegradable plates and screws. J Craniofac Surg 2008;19:748-56. https://doi.org/10.1097/SCS.0b013e31816aab24
  13. Turvey TA, Bell RB, Tejera TJ, Proffit WR. The use of self-reinforced biodegradable bone plates and screws in orthognathic surgery. J Oral Maxillofac Surg 2002;60:59-65.
  14. Bostman O, Pihlajamaki H. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials 2000;21:2615-21. https://doi.org/10.1016/S0142-9612(00)00129-0
  15. Choi HJ, Kim W, Youn S, Lee JH. Management of delayed infection after insertion of bioresorbable plates at the infraorbital rim. J Craniofac Surg 2012;23:524-5. https://doi.org/10.1097/SCS.0b013e31824cd4de
  16. Middleton JC, Tipton AJ. Synthetic biodegradable polymers as orthopedic devices. Biomaterials 2000;21:2335-46. https://doi.org/10.1016/S0142-9612(00)00101-0
  17. Laughlin RM, Block MS, Wilk R, Malloy RB, Kent JN. Resorbable plates for the fixation of mandibular fractures: a prospective study. J Oral Maxillofac Surg 2007;65:89-96.
  18. Landes CA, Ballon A, Roth C. In-patient versus in vitro degradation of P(L/DL)LA and PLGA. J Biomed Mater Res B Appl Biomater 2006;76:403-11. https://doi.org/10.1002/jbm.b.30388
  19. Oonishi H, Hench LL, Wilson J, Sugihara F, Tsuji E, Kushitani S, et al. Comparative bone growth behavior in granules of bioceramic materials of various sizes. J Biomed Mater Res 1999;44:31-43. https://doi.org/10.1002/(SICI)1097-4636(199901)44:1<31::AID-JBM4>3.0.CO;2-9
  20. Furukawa T, Matsusue Y, Yasunaga T, Shikinami Y, Okuno M, Nakamura T. Biodegradation behavior of ultra-high-strength hydroxyapatite/poly (L-lactide) composite rods for internal fixation of bone fractures. Biomaterials 2000;21:889-98. https://doi.org/10.1016/S0142-9612(99)00232-X

Cited by

  1. Bone Regeneration Capacity of Newly Developed Uncalcined/Unsintered Hydroxyapatite and Poly- L -lactide-co-glycolide Sheet in Maxillofacial Surgery: An In Vivo Study vol.11, pp.1, 2021, https://doi.org/10.3390/nano11010022
  2. Bioactive Regeneration Potential of the Newly Developed Uncalcined/Unsintered Hydroxyapatite and Poly-l-Lactide-Co-Glycolide Biomaterial in Maxillofacial Reconstructive Surgery: An In Vivo Preliminary vol.14, pp.9, 2019, https://doi.org/10.3390/ma14092461
  3. A Narrative Review of u-HA/PLLA, a Bioactive Resorbable Reconstruction Material: Applications in Oral and Maxillofacial Surgery vol.15, pp.1, 2022, https://doi.org/10.3390/ma15010150