DOI QR코드

DOI QR Code

Evaluation of Ventilation Deficiecy in Elementary, Middle, and High Schools using Monte Carlo Simulation

Monte-Carlo 모의실험을 이용한 초·중·고등학교의 환기부족 평가

  • Choe, Youngtae (Department of Occupational Health, Daegu Catholic University) ;
  • Park, Jinhyeon (Department of Occupational Health, Daegu Catholic University) ;
  • Kim, Eunchae (Department of Occupational Health, Daegu Catholic University) ;
  • Ryu, Hyoensu (Department of Occupational Health, Daegu Catholic University) ;
  • Kim, Dong Jun (Department of Occupational Health, Daegu Catholic University) ;
  • Min, Kihong (Department of Occupational Health, Daegu Catholic University) ;
  • Jung, Dayoung (Department of Occupational Health, Daegu Catholic University) ;
  • Woo, Byung Lyul (Department of Occupational Health, Daegu Catholic University) ;
  • Cho, Mansu (Department of Occupational Health, Daegu Catholic University) ;
  • Yang, Wonho (Department of Occupational Health, Daegu Catholic University)
  • 최영태 (대구가톨릭대학교 산업보건학과) ;
  • 박진현 (대구가톨릭대학교 산업보건학과) ;
  • 김은채 (대구가톨릭대학교 산업보건학과) ;
  • 류현수 (대구가톨릭대학교 산업보건학과) ;
  • 김동준 (대구가톨릭대학교 산업보건학과) ;
  • 민기홍 (대구가톨릭대학교 산업보건학과) ;
  • 정다영 (대구가톨릭대학교 산업보건학과) ;
  • 우병렬 (대구가톨릭대학교 산업보건학과) ;
  • 조만수 (대구가톨릭대학교 산업보건학과) ;
  • 양원호 (대구가톨릭대학교 산업보건학과)
  • Received : 2020.09.17
  • Accepted : 2020.10.16
  • Published : 2020.12.31

Abstract

Objectives: Indoor air quality has become more important aspeople spend most of their times indoors. Since students spend most of their times at home or at school, they are more likely to be exposed to indoor air pollutants. Ventilation in school classrooms can affect health and learning performance. In this study, ventilation deficiency was evaluated in school classrooms using Monte Carlo simulation. Methods: This study used sensor-based monitoring for six months to measure carbon dioxide (CO2) concentrations in classrooms in elementary, middle, and high schools. The volume of the classroom and the number of students were investigated, and the students' body surface area was used to calculate the CO2 emission rate. The distribution of ventilation rates was estimated by measured CO2 concentration and a mass-balance model using Monte Carlo simulation. Results: In the elementary, middle, and high schools, the average CO2 concentrations exceeded 1000 ppm, indicating that the ventilation rates were insufficient. The ventilation rates were deficient from July to August and in December, but showed relatively high ventilation rates in October. Forty-three percent of elementary schools, 56% of middle schools, and 62% of high schools showed insufficient ventilation rates. Conclusions: The ventilation rates calculated in elementary, middle and high schools were found to be quite insufficient. Therefore, proper management is needed to overcome the lack of ventilation and improve air quality.

Keywords

Acknowledgement

본 연구는 환경부의 재원으로 한국환경산업기술원의 생활공감환경보건기술사업의 지원을 받아 수행되었습니다(과제번호: 2018001350001).

References

  1. Yang W, Lee K, Park K, Yoon C, Son B, Jeon JM, Lee H, Choi WH, Yu SD, Han JS. Microenvironmental time activity patterns of weekday and weekend on korean, Korean Journal of Environmental Health 2009; 29(10): 267-274.
  2. Yang W, Lee K, Chung M. Characterization of indoor air quality using multiple measurements of nitrogen dioxide. Indoor Air. 2004; 14: 105-111. https://doi.org/10.1046/j.1600-0668.2003.00216.x
  3. United state environmental protection agency. Improving indoor air quality. https://www.epa.gov/indoor-air-quality-iaq/improving-indoor-air-quality#Ventilation_improvements [accessed 22 January 2019].
  4. Ring E, Brager G. Occupant comfort, control, and satisfaction in three california mixed-mode office buildings. ACEEE Summer Study on Energy efficiency in Buildings. 2000; 8314-8328.
  5. Sundell J. On the history of indoor air quality and health. Indoor Air. 2004; 14(7): 51-58. https://doi.org/10.1111/j.1600-0668.2004.00273.x
  6. Yang W. Time-activity pattern of students and indoor air quality of school. Korean Institute of Educational Facilities. 2014; 21(6): 17-22.
  7. Landrigan P. Environmental hazards for children in USA. International Journal of Occupational Medicine and Environmental Health. 1998; 11(2): 189-194.
  8. Camilla V, Kati J, Sander T, Kaiser A, Maria A, Raimo M, et al. Ventilation positive pressure intervention effect on indoor air quality in a school building with moisture problems. Environmental Research and Public Health. 2018; 15(2): 230. https://doi.org/10.3390/ijerph15020230
  9. Lim W. Literature review of the effect of the carbon dioxide concentration in classroom air on the students learning performance. Korean Journal of Environmental Education. 2015; 28(2): 134-145. https://doi.org/10.17965/kjee.2015.28.2.134
  10. Shendell D, Prill R, Fisk W, Apte M, Blake D, Faulkner D. Associations between classroom CO2 concentrations and student attendance in washington and idaho. Indoor Air. 2004; 14: 333-341. https://doi.org/10.1111/j.1600-0668.2004.00251.x
  11. Almeida SM, Canha N, Silva A, do Carmo Freitas M, Pegas P, Alves C. Evtyugina M, Adriao Pio C. Children exposure to atmospheric particles in indoor of lisbon primary schools. Atmospheric Environment. 2011; 45: 7594-7599. https://doi.org/10.1016/j.atmosenv.2010.11.052
  12. National institute of meteorological sciences. Report of global atmosphere watch. 2018.
  13. Lee J, Choi J, Kim H. Determination of body surface area and formulas to estimate body surface area using the alginate method. Journal of Physiological Anthropology 2008; 27(2): 71-82. https://doi.org/10.2114/jpa2.27.71
  14. National Institute of Environmental Research. Study on the improvement of exposure factors of korean adults on risk assessment. 2018.
  15. David A, Alexander B. Carbon dioxide levels and ventilation rates in schools. International Journal of Ventilation. 2002; 1(1): 45-52. https://doi.org/10.1080/14733315.2002.11683621
  16. Douglas H. How to measure anything: finding the value of Intangibles in business, John Wiley & Sons, 2007, p. 46.
  17. Korea ministry of government legislation. Enforcement decree of the school health act. 2018.
  18. Choe Y, Heo J, Park J, Kim E, Ryu H, Kim D, et al. Evaluation of carbon dioxide concentration and ventilation rates in elementary, middle and high Schools. Korean Journal of Environmental Health 2020; 46(3): 1-9.
  19. Anna M, Elwira Z. Determination on carbon dioxide levels in school buildings: the effect of thermal efficiency improvement. Engineering and Protection of Environment 2019; 21(2), 155-162.
  20. Ministry of education. School environmental hygiene and food hygiene management manual. 2019.
  21. Kim S, Kim J, Kim J. A study on the CO2 concentration control in lecture room. Korea Institute of Architectural Sustainable Environment and Building Systems. 2012; 97-100.