The Change of Collected Light According to Changing of Reflectance and Thickness of CdWO4 Scintillator for High Energy X-ray Imaging Detection

고에너지 X-선 영상검출을 위한 CdWO4 섬광체 두께와 반사체의 반사율 변화에 따른 광 수집량의 변화

  • Received : 2020.10.28
  • Accepted : 2020.11.19
  • Published : 2020.12.31

Abstract

The high-energy X-ray imaging detector used for container inspection uses a thick scintillator to effectively acquire X-rays. X-ray incident on the scintillator is generally up to 9MeV. Therefore, to effectively collect X-ray, it is necessary to use a thick scintillator. To collect the light generated by the reaction between X-ray and scintillator, an optical-sensor must be combined with the scintillator. In this study, a study on the design conditions of the detector using a CdWO4 and a small sensor is described. To calculate the collected light according to the change of the scintillator thickness and the reflectance of surface, MCNP6 and DETECT2000 were used. As a result of calculating, it was confirmed that when the reflectance of the surface was low, it was appropriate to select a scintillator with a thickness of 15 to 20-mm, but as the reflectance increased, it was confirmed that it was appropriate to select a CdWO4 with a thickness of 25 to 30-mm.

컨테이너 검색을 위해 사용되는 고에너지 X-선 영상획득용 검출기는 입사되는 고에너지 X-선을 효과적으로 획득하기 위하여 MeV X-선 수집이 충분히 수행될 수 있는 두께의 섬광체를 사용한다. 컨테이너 검색기에서는 섬광체에 입사되는 X-선의 에너지는 일반적으로 최대 9MeV의 X-선이 사용된다. 그러므로 고에너지 X-선 광자를 효과적으로 수집하기 위해서는 수 cm 두께의 섬광체가 이용되어야 하며 섬광체의 두께는 신호의 수집효율에 영향을 미치게 된다. 본 연구에서는 컨테이너 검색에 사용되는 CdWO4 섬광체와 소면적의 센서를 활용한 영상검출기의 설계조건에 대한 연구를 기술하고 있다. 이를 위하여 본연구에서는 섬광체의 적절한 두께와 섬광체 표면의 반사율에 따른 빛 수집효율을 계산하기 위하여 MCNP6와 DETECT2000을 활용하여 다양한 조건에서 X-선 거동과 빛의 거동에 대한 모사를 수행하였다. 빛 수집효율 계산결과 섬광체 표면의 반사율이 낮은 경우 대략 15 ~ 20mm 두께의 섬광체를 선정하는 것이 적합하였으나 반사율이 높아짐에 따라 대략 25 ~ 30mm 두께의 CdWO4 섬광체를 선정하는 것이 적합한 것으로 확인되었다.

Keywords

References

  1. G. Chen, "Understanding X-ray cargo imaging," Nuclear Instruments and Methods in Physics Research B, vol. 241, pp. 810-815, Aug. 2005. https://doi.org/10.1016/j.nimb.2005.07.136
  2. C. Michail, V. Koukou, N. Martini, G. Saatsakis, N. Kalyvas, A. Bakas, I. Kandarakis, G. Fountos, G. Panayiotakis, and I. Valais, "Luminescence efficiency of cadmium tungstate (CdWO4) single crystal for medical imaging applications," Crystals, vol. 10, no. 429, pp. 1-16, May. 2020.
  3. J. Lee, C. H. Lim, J. Park, I. Kim, M. K. Moon, and Y. Lim, "The effect of grid ratio and material of anti-scatter grid on the scatter-to-primary ratio and the signal-to-noise ratio improvement factor in container scanner x-ray imaging," Radiation Protection and Research, vol. 42, no. 4, pp. 197-204, Oct. 2017. https://doi.org/10.14407/jrpr.2017.42.4.197
  4. T. T. Monajemi, S. Steciw, B. G. Fallone, and S. Rathee, "Modeling scintillator-photodiodes as detectors for megavoltage CT," Medical Physics, vol. 31, no. 5, pp. 1225-1234, May. 2004. https://doi.org/10.1118/1.1710733
  5. A. Badano, R. M. Gagne, B. D. Gallas, R. J. Jennings, J. S. Boswell, and K. J. Myers, "Lubberts effect in columnar phosphors," Medical Physics, vol. 31, no. 11, pp. 3122-3131, Nov. 2004. https://doi.org/10.1118/1.1796151
  6. P. M. Evans, M. A. Mosleh-Shirazi, E. J. Harris, and J. Seco, "Monte Carlo and Lambertian light guide models of the light output from scintillation crystals at megavoltage energies," Medical Physics, vol. 33, no. 6, pp. 1797-1809, May. 2006. https://doi.org/10.1118/1.2199597
  7. D. Sharma, C. Sze, H. Bhandari, V. Nagarkar, and A. Badano, "Depth-of-interaction estimates in pixelated scintillator sensors using Monte Carlo techniques," Nuclear Instruments and Methods in Physics Research A, vol. 841, pp. 117-123, 2017. https://doi.org/10.1016/j.nima.2016.10.028
  8. P. Ghorbani, D. Sardari, R. Azimiradb, and M. Hosntalab, "Assessment of optical photon collection in a large plastic scintillator using Geant4-Gate code," Optik, vol. 158, pp. 305-311, 2018. https://doi.org/10.1016/j.ijleo.2017.12.111