Development of High Energy X-ray Dose Measuring Device based Ion Chamber for Cargo Container Inspection System

이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발

  • Received : 2020.10.28
  • Accepted : 2020.11.17
  • Published : 2020.12.31

Abstract

X-ray of up to 9MeV are used for container inspection. X-ray intensity must be maintained stably regardless of changes in time. If dose is not constant, it may affect the image quality, and as a result, may affect the inspection of abnormal cargo. Therefore, to acquire high-quality images, continuous dose monitoring is required. In this study, the ion-chamber based device was developed for monitoring the dose change in high-energy x-ray. And to estimate the performance of signal-processing device change according to the environmental change, the output changing due to the change of temperature and humidity was observed. In addition, verification of the device was performed by measuring the output change. As a result of the measurement, there was no significant difference in performance due to changes in temperature and humidity, and the change in output according to the change in exposure was linear. Therefore, it was found that the developed device is suitable for the dose monitoring of high-energy x-ray.

일반적으로 컨테이너 내부검사를 위해서는 최대 9MeV의 X-선을 사용한다. 이때 사용되는 X-선은 선형가속기를 통해 생성되며 일정한 세기의 X-선량이 시간의 변화에 관계없이 안정적으로 유지되어야 한다. 만약 발생되는 X-선의 세기가 일정하지 않다면 영상의 해상도와 대비도 등에 영향을 미칠 수 있으며 결과적으로 컨테이너 내부의 이상화물에 대한 검사에 영향을 미칠 수 있다. 그러므로 고화질의 영상을 획득하기 위해서는 발생되는 X-선 선량에 대한 지속적인 모니터링이 요구된다. 이와같은 선량 모니터링을 위하여, 본 연구에서는 고에너지 X-선 선량의 변화 측정을 위한 이온전리함 기반의 선량변화 측정장치를 개발하였고 환경변화에 따른 신호처리부의 성능변화를 확인하기 위하여 온도와 습도 변화에 의한 측정값의 변화를 관찰하였다. 또한, 고에너지 X-선 발생장치에서 발생되는 선량의 변화에 따른 응답특성변화를 측정함으로써 개발한 X-선 선량측정장치의 검증을 수행하였다. 측정결과 온도와 습도의 변화에 따른 성능의 차이가 크게 나타나지 않았으며 입사되는 선량의 변화에 따른 출력의 변화가 선형적이었다. 그러므로 개발한 이온전리함 기반의 선량변화측정장치는 고에너지 X-선의 선량변화의 측정에 적용하기에 적합함을 알 수 있었다.

Keywords

References

  1. J. Bendahan, "Vehicle and Cargo Scanning for Contraband," Physics Procedia, vol. 90, pp. 242-255, 2017. https://doi.org/10.1016/j.phpro.2017.09.003
  2. G. Zentai, "X-ray imaging for homeland security," International Journal of Signal and Imaging Systems Engineering, vol. 3, no. 1, pp. 13-20, 2010. https://doi.org/10.1504/IJSISE.2010.034628
  3. G. Chen, "Understanding X-ray cargo imaging," Nuclear Instruments and Methods in Physics Research B, vol. 241, pp. 810-815, Aug. 2005. https://doi.org/10.1016/j.nimb.2005.07.136
  4. M. K. Tyler, P. Z. Y. Liu, C. Lee, D. R. McKenzie, and N. Suchowerska, "Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators," Journal of Applied Clinical Medical Physics, vol. 17, no. 3, pp. 223-235, May. 2016. https://doi.org/10.1120/jacmp.v17i3.6059
  5. J. Lee, I. Kim, J. W. Park, Y. K. Lim, M. Moon, S. Lee, and C. H. Lim, "Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device," Journal of Radiation Protection and Research, vol. 43, no. 3, pp. 97-106, Sep. 2018. https://doi.org/10.14407/jrpr.2018.43.3.97
  6. J. Lee, C. H. Lim, J-W. Park, I. Kim, M. Moon, and Y-K. Lim, "The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging," Journal of Radiation Protection and Research, vol. 42, no. 4, pp. 197-204, Sep. 2017. https://doi.org/10.14407/jrpr.2017.42.4.197
  7. D. A. Low, J. M. Moran, J. F. Dempsey, L. Dong, and M. Oldham, "Dosimetry tools and techniques for IMRT," Medical Physics, vol. 38, pp. 1313-1338, Feb. 2011. https://doi.org/10.1118/1.3514120