DOI QR코드

DOI QR Code

Design of gas suspension absorber to improve desulfurization efficiency

  • Hwang, Woohyeon (School of Robot & Automation Engineering, Dongyang Mirae University) ;
  • Lee, Kyung-Ok (Dept. of Chem. & Environ. Eng., Gyeonggi Univ. of Science & Technology)
  • Received : 2020.01.29
  • Accepted : 2020.02.17
  • Published : 2020.02.28

Abstract

In this study, the inlet duct and guide vane of the gas floating absorption tower were redesigned to improve the desulfurization efficiency so that the exhaust gas can be uniformly introduced into the absorption tower. In order to reduce the sulfur oxide pollutants among the main sources of air pollutants in industrial boilers, the existing equipment is redesigned and solved. For this purpose, change the exhaust gas, the slurry and recycling the adsorbent to improve the removal efficiency of SOx component in the exhaust gas inside the gas floating absorption tower so as to uniformly contact. And the initial design value and CFD value for the pressure loss from the boiler outlet to the gas floating absorption tower outlet are verified. Also, the velocity distribution of the exhaust gas, the concentration distribution of the recycled adsorbent, the liquid slurry behavior, and the pressure loss were compared. The results confirmed that the desulfurization efficiency was improved because the pressure loss from the boiler outlet to the absorption tower outlet was reduced and the deflection of the exhaust gas was minimized.

본 연구에서는 배기가스가 흡수탑으로 균일하게 유입될 수 있도록 가스 부유식 흡수탑의 입구덕트와 안내깃을 다시 설계하여 탈황효율을 높이고자 한다. 산업용 보일러에서 대기오염 물질의 주 발생원인 중에서 황산화물의 오염물질을 저감하기 위해 기존의 장치를 다시 설계하여 해결하고자 한다. 이를 위하여 가스 부유식 흡수탑 내부에서 배기가스 중에 SOx 성분의 제거효율을 높일 수 있도록 배기가스, 슬러리와 재순환 흡착제가 균일하게 접촉하도록 변경한다. 그리고 보일러 출구에서부터 가스 부유식 흡수탑 출구까지 압력손실에 대한 초기 설계값과 CFD 값을 비교하여 검증한다. 또한 배기가스의 속도분포, 재순환 흡착제 농도분포, 액상 슬러리 거동, 압력손실을 각각 비교하였다. 그 결과는 보일러 출구에서부터 흡수탑 출구까지 압력손실이 감소하고, 배기가스의 편향이 최소화되므로 인해 탈황 효율이 개선되었음을 확인하였다.

Keywords

References

  1. M. Sa, and I. Woo, "A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers," Journal of The Korea Institute of Gas, Vol. 23, No. 4, pp.1-9, August 2019. DOI: 10.7842/kigas.2019.23.4.1
  2. Y. Cho, H. Choi, J. Lee, Y. Kim, and H. Yoo, Experimental Selection of Slurry pH Value for Proper Operation in 200 MW Power Plant, Proceeding of the Society of Air-Conditioning And Refrigerating Engineers Of Korea, pp.329-334, Korea, June 2017.
  3. W. Hwang, and K. Lee, “Mixer design for improving the injection uniformity of the reduction agent in SCR system,” Journal of The Korea Society of Computer and Information, Vol. 22, No. 1, pp. 63-69, January 2017. DOI: 10.9708/jksci.2017.22.01.063
  4. W. Hwang, and K. Lee, "Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas," Journal of The Korea Society of Computer and Information, Vol. 19, No. 2, pp. 161-171, February 2014. DOI: 10.9708/jksci.2014.19.2.161
  5. W. Hwang, K. Lee, and Y. Cho, "Optimization of the Design of Large Ducts with the Space Constraint in 500MW Power Plant," Journal of Environmental Sciences., Vol. 18, No. 7, pp. 755-765, July 2009. DOI: 10.5322/JES.2009.18.7.755
  6. S. Cignitti, S. S. Mansouri, M. Sales-Cruz, F. Jensen, and J.K. Huusom, "Dynamic Modeling and Analysis of an Industrial Gas Suspension Absorber for Flue Gas Desulfurization," Emission Control Science and Technology, Vol. 2, No. 1, pp.20-32, January 2016. DOI: 10.1007/s40825-015-0028-5
  7. Y. Lee, H. Kim, J Choi, J. Poudel, and S. Oh, The CFD interpretative Study of more than 50ton/day Stoker Boiler for getting over combustion difficulty, Proceedings of the 2018 Spring Conference of the Korea Society of Waste Management, p.104, May 2018.
  8. Z. Chen, H. Wang, J. Zhuo, and C. You, "Experimental and numerical study on effects of deflectors on flow field distribution and desulfurization efficiency in spray towers," Fuel processing technology, Vol. 162, pp.1-12, July 2017. DOI: 10.1016/j.fuproc.2017.03.024
  9. K. Kim, and S. Moon, "Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs," Plant journal, Vol. 14, No. 4, pp.39-47, December 2018.
  10. J. Zhu, S. Ye, and J. Bai, "A concise algorithm for calculating absorption height in spray tower for wet limestone-gypsum flue gas desulfurization," Fuel Processing Technology, Vol. 129, pp.15-23, January 2015. DOI: 10.1016/j.fuproc.2014.07.002
  11. H. An, S. Park, K. Kim, and Y. Kim, "A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System," Journal of Korean Ind. Eng. Chem., Vol. 18, No. 1, pp.29-35, February 2007.
  12. M. Qin, Y. Dong, L. Cui, J. Yao and C. Ma, "Pilot-scale experiment and simulation optimization of dual-loop wet flue gas desulfurization spray scrubbers," Chemical Engineering Research and Design, V. 148, p.280-290, August 2019. DOI: 10.1016/j.cherd.2019.06.011
  13. H. Um, G. Kim, D. Kim, K. Kim, and J. Kim, Numerical Analysis for the Flow Uniformity in the LP-SCR Reactor, Proceedings of The Korean Society Of Combustion SYMPOSIUM, p.61-63, December 2015.
  14. S. Wang, P. Zhu, G. Zhang, Q. Zhang, Z. Wang, and L. Zhao, "Numerical simulation research of flow field in ammonia-based wet flue gas desulfurization tower," Journal of the Energy Institute, Vol. 88, No. 3, p. 284-291, August 2015. DOI: 10.1016/j.joei.2014.09.002
  15. P. Cordoba, "Status of Flue Gas Desulphurisation (FGD) systems from coal-fired power plants: Overview of the physic-chemical control processes of wet limestone FGDs," Fuel, V. 144, No. 15, p.274-286, March 2015. DOI: 10.1016/j.fuel.2014.12.065