Development of Automated Non-Destructive Ultrasonic Inspection Equipment for Welding Crack Inspection

용접크랙검사용 비파괴 초음파탐상 자동화검사장비 개발

  • Received : 2019.10.21
  • Accepted : 2020.02.15
  • Published : 2020.02.29

Abstract

This research is related to a development of the ultrasonic detector for an internal defect detection of various assembly part's welding zone. In this research, measurement S/Ws including system's motion control, S/W ultrasonic transmitter/receiver control, defect judgment standard setting, etc. have been designed for ultrasonic detection, and welding defects sample network, etc. were also designed for comparison between products in good condition and defective products. Through this kind of system, automatic detection function can be performed for the depth and the defect location of the assembly parts welding zone, and the system is able to make a judgment of internal defect detection which is used to be performed by an expert in the past.

본 연구는 다양한 어셈블리 부품의 용접부 내부결함을 검사하기 위한 초음파 탐상 장비 개발에 관한 것이다. 본 연구에서는 초음파 탐상을 위하여 시스템의 모션제어 S/W, 초음파 송수신기 제어, 결함 판정 기준 설정 등의 계측 S/W 등이 설계되었으며, 양품과 불량품의 비교분석을 하기 위하여 용접결함 불량품 샘플워크 등도 제작되었다. 이와 같은 구성으로 이루어진 시스템을 통하여 어셈블리 부품 용접부의 결함 위치 및 깊이에 대한 자동검사 기능을 수행할 수 있었으며, 종전에 전문가에 의해 이루어졌던 용접부의 내부결함에 대한 판단을 시스템이 수행하도록 하였다.

Keywords

References

  1. K. Kim, "Detection of Flaws in Ceramic Materials Using Non-Destructive Testing," J. of the Korea Institute of Electronic Communication Sciences, vol. 5, no. 3, June 2010, pp. 321-326.
  2. B. Whang, "The Measurement System of Space Charge Distribution in Polymer Dielectric Materials by the PEA Method," J. of the Korea Institute of Electronic Communication Sciences, vol. 7, no. 6, Dec. 2012, pp. 1403-1411. https://doi.org/10.13067/JKIECS.2012.7.6.1403
  3. L. Janousek, K. Capova, N. Yusa, and K. Miya, "Multiprobe inspection for enhancing sizing ability in eddy current nondestructive testing," IEEE Trans. vol 44, no. 6, May. 2008, pp. 1618-1621.
  4. Y. Park, "A study of Water Level Control System," J. of the Korea Institute of Electronic Communication Sciences, vol. 5, no. 5, Oct. 2010, pp. 504-508.
  5. J. Choi, "Study on the Development of Multi-Agents Position Tracking System Using Ultrasonic Transducers," J. of the Korea Institute of Electronic Communication Sciences, vol. 8, no. 5, June 2013, pp. 725-731. https://doi.org/10.13067/JKIECS.2013.8.5.725
  6. J. Choe, W. Cho, and I. Choy, "Ultrasonic Distance Measurement Method Based on Received Signal Model," J. of the Korea Institute of Electronic Communication Sciences, vol. 12, no. 1, Feb. 2017, pp. 53-60. https://doi.org/10.13067/JKIECS.2017.12.1.53
  7. T. Kim, N. Ko, and S. No, "Particle Filter SLAM for Indoor Navigation of a Mobile Robot Using Ultrasonic Beacons," J. of the Korea Institute of Electronic Communication Sciences, vol. 7, no. 2, Apr. 2012, pp. 391-399. https://doi.org/10.13067/JKIECS.2012.7.2.391
  8. K. Yoon, "Improved Localization Algorithm for Ultrasonic Satellite System," J. of the Korea Institute of Electronic Communication Sciences, vol. 6, no. 5, Oct. 2011, pp. 775-781. https://doi.org/10.13067/JKIECS.2011.6.5.775
  9. I. Choy, H. Jung, B. Yoo, and U. Kim, "Power Supply of Ultrasonic Phased Array for Focus Control of Acoustic Pressure," J. of the Korea Institute of Electronic Communication Sciences, vol. 14, no. 1, Feb. 2013, pp. 137-146. https://doi.org/10.13067/JKIECS.2019.14.1.137
  10. Y. Ko and W. Lee, "A Study on the Development of High-intensity focused Ultrasound Device for the Beauty Treatment Health Care," J. of the Korea Institute of Electronic Communication Sciences, vol. 11, no. 12, Dec. 2016, pp. 1259-1264. https://doi.org/10.13067/JKIECS.2016.11.12.1259