본 연구는 ECG 신호를 이용하여 AR/VR 장치 사용 중에 발생할 수 있는 스트레스와 심장 상태에 따른 위험 예측을 위한 실시간 분석 시스템을 개발하였다. 제안 방법에는 ECG 신호의 R-R 간격을 이용한 HRV, BPM 측정법과 선행연구를 이용하여, 2차원 공간의 대치방법을 통해 실시간 진단방법을 제안하였다. 5분단 위로 ECG 데이터를 분석하고 자율신경계 진단 결과로 도출했다.

In this study, we proposed a real-time ECG analytical method for predicting stress and dangerous heart condition using the ECG signal in playing AR/VR device. A real-time diagnosis is used as R-R interval based HRV(:Heart rate variability), BPM(:Beats Per Minitue) and autonomic nervous research with through mapping method of two-dimensional planes. The ECG data were analyzed every 5 minutes and derived from autonomic nervous system diagnosis.

키워드

참고문헌

  1. D. Henry, B. Fernandez, M. Koji, and K. Kondo, "Adaptable Game Experience Based on Player's Performance and EEG," In Proc. IEEE Nicograph Int. Conf. Kyoto, Japan, June 2017, pp. 1-8.
  2. W. Hu, J. Meyer, Z. Wang, T. Reid, D. Adams, S. Prabankar, and A. Chaturedi, "Dynamic Data Driven Approach for Modeling Human Error," J. of Procedia Computer Science, vol. 51, 2015, pp. 1643-1654. https://doi.org/10.1016/j.procs.2015.05.298
  3. NeuroSky Inc, "The introductory Guide to EEG & BCI for Entertainment," Technical report, June 2018.
  4. A. Brouwer, M. Neerincx, V. Kallen, L. Leer, and M. Brinke, "EEG alpha asymmetry, heart rate variability and cortisol in response to Virtual Reality induced stress," J. of Cyber Therapy and Rehabilitation, vol. 4, no. 1, Jan. 2011, pp. 83-99.
  5. R. Negoescu, S. Dinca-Panaitescu, V. Filcescu, D. Ionescu, and S. Wolf, "Mental stress enhances the sympathetic fraction of QT variability in an RR-independent way," J. of Integrative Physiological and Behavioral Science, vol. 32, no. 3, July 1997, pp. 220-227. https://doi.org/10.1007/BF02688620
  6. D. Han, N. Jeong, D. Kim, Y. Kim, and C. Lee, "Analysis of Stress Level of Korean by Heart Rate Variability Measurement," J. of The Korean Society of Stress Medicine. vol. 15, no. 3, Sept. 2007, pp. 163-169.
  7. W. Kim, "A Study on measurement Techniq -ue of HRV for elder with reduced cognitive abilities," J. of The Korea Institute of Electronic Communication Sciences, vol. 10, no. 1, Jan. 2015, pp. 125-132. https://doi.org/10.13067/JKIECS.2015.10.1.125
  8. S. Yoon and G. Kim, "Personal Biometric Identification based on ECG Features," J. of The Korea Institute of Electronic Communication Sciences, vol. 10, no. 4, Apr. 2015, pp. 521-526. https://doi.org/10.13067/JKIECS.2015.10.4.521
  9. J. Healey and R. Picard, "Detecting stress during real-world driving tasks using physiological sensors," IEEE Tran. on Intelligent Transportation Systems, vol. 6, no. 2, June 2005, pp. 156-166. https://doi.org/10.1109/TITS.2005.848368
  10. J. Carter and C. Ray, "Sympathetic neural responses to mental stress: Responders, nonresponders and sex differences," American J. of Physiology -Heart and Circulatory Physiology, vol. 296, no. 3, Mar. 2009, pp. 847-853. https://doi.org/10.1152/ajpheart.01234.2008
  11. H. Kim, E. Cheon, D. Bai, Y. Lee, and B. Koo, "Stress and Heart Rate Variability: A Meta-Analysis and Review of the Literature," J. of Psychiatry Investig, vol. 15, no. 3, Mar. 2018, pp. 235-245. https://doi.org/10.30773/pi.2017.08.17
  12. C. Chen, C. Li, C. Tsai, and X. Deng, "Evaluation of Mental Stress and Heart Rate Variability Derived from Wrist-Based Photo plethysmo graphy," IEEE Eurasia ECBIOS, int. conf. Okinawa, Japan, Aug. 2019, pp. 65-68.
  13. H. Park, J. Lee, and B. Kim, "Development of blood pressure estimation methods using the PPG and ECG sensors," J. of the Korea Institute of Electronic Communication Sciences, vol. 14, no. 6, Dec. 2019, pp. 1257-1264. https://doi.org/10.13067/JKIECS.2019.14.6.1257
  14. J. Kim, B. Kim, S. Park, Y. Lee, N. Keum, and H. Bae, "The Effects of Paced Breathing in Specific Respiration Rate on Heart Rate Variability," J. of The Society of Korean Medicine, vol. 28, no. 2, June 2016, pp. 123-131.
  15. M. Vollmer, "A robust, simple and reliable measure of heart rate variability using relative RR intervals," In 2015 Computing in Cardiology Conf. Nice, France, Sept. 2015, pp. 609-612.