DOI QR코드

DOI QR Code

A Study on the Water Pollutant Discharge Inventories for the Improvement of Industrial Wastewater Management System: Primary Steel Manufacturing Facility and Petroleum Refining Products Manufacturing Facility

산업폐수 관리체계 개선을 위한 수질오염물질 배출목록 구축에 대한 연구: 1차 철강 제조업과 석유정제품 제조업

  • Received : 2020.07.23
  • Accepted : 2020.09.18
  • Published : 2020.09.30

Abstract

This study aimed to inventory the water pollutant discharge of wastewater from two facilities, one primary steel manufacturing facility and one petroleum refinery, both of which are located in Korea, and to identify ways to improve the wastewater treatment process through field investigation. Probability evaluation was used to inventory the substances in polluted water. The samples collected in this study included original wastewater, on processing wastewater, and treated water. The general description of wastewater occurrence, major sources, and treatment facilities were also investigated to obtain an integrated database of the pollutants created by different industrial categories. Based on our analysis of raw wastewater and final effluent, the detected pollutants were confirmed by analyzing their presence in the raw or supplemental materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The compounds detected for each category were screened via investigation of their possible sources and confirmed as the final water pollutant inventories. Thirty kinds of water pollutants were emitted by the primary steel manufacturing facility (reference in case A), including 14 specified hazardous water pollutants. The petroleum refinery (reference in case B) emitted 36 water pollutants, including 16 specified hazardous water pollutants.

Keywords

References

  1. Ahn, T. U., Kim, W. K., Son, D. H., Yeom, I. T., Kim, J. H., and Yu, S. J. (2016). Study on discharge characteristics of water pollutants among industrial wastewater per industrial classification and the probability evaluation, Journal of Korean Society on Engineering geology, 38(1), 14-24. [Korean Literature] https://doi.org/10.4491/KSEE.2016.38.1.14
  2. Cho, Y. H., Kil, G. B., Lee, J. B., Im, J. K., Kim, J. H., Rhew, D. H., Yu, S. J., and Lee, S. H. (2015). Investigation of water pollutants in wastewater discharge facilities(VI) - Petroleum refining products manufacturing facility and alcoholic drink manufacturing facility-, Journal of Korean Society on Water Environment, 457-458. [Korean Literature]
  3. European Commission. (2001). Integrated Pollution Prevention and Control(IPPC) Reference Document on Best Available Techniques for the Ferrous Metals Processing Industry, 475-477.
  4. European Commission., (2010), Integrated Pollution Prevention and Control(IPPC) Reference Document on Best Available Techniques for Refining of Mineral Oil and Gas. 377-390.
  5. Kim, J. H. (2012). Study on establishment of the industrial wastewater effluent limitations based on best practicable control technology currently available, Journal of Korean Society on Water Environment, 28(4), 608-614. [Korean Literature]
  6. Kwon, O. S., Jung, J. Y., Heo, T. Y., Jeon, H. B., Lee, Y. H., and Park, S. M. (2012). Establishment of effluent limitation based on wastewater characteristics and treatment technology, Journal of Korean Society on Water Environment, 28(6), 804-812. [Korean Literature]
  7. Ministry of Environment (ME). (2008). Improvement of wastewater management system for industry, Ministry of Environment, 3-19. [Korean Literature]
  8. Ministry of Environment (ME). (2012). Survey of specific hazardous substances from wastewater by industrial wastewater treatment plants, Ministry of Environment, 1-5. [Korean Literature]
  9. Ministry of Environment (ME). (2016). Standard Methods for the Examination of Water, Ministry of Environment. [Korean Literature]
  10. National Institute of Environmental Research (NIER). (2006). Industrial wastewater discharge facility class and unit loads of pollutants, National Institute of Environmental Research, 192-193. [Korean Literature]
  11. National Institute of Environmental Research (NIER). (2011a). A study on the analysis of the impacts of expansion new permit system on the expansion of new administrative system, National Institute of Environmental Research, 1-3. [Korean Literature]
  12. National Institute of Environmental Research (NIER). (2011b). Monitoring of hazardous chemicals for wastewater discharge facilities in the Nakdong river basin(II), National Institute of Environmental Research, 1-2. [Korean Literature]
  13. National Institute of Environmental Research (NIER). (2012). A study on discharge of hazardous water pollutants in industrial wastewater, National Institute of Environmental Research, 1-10. [Korean Literature]
  14. National Institute of Environmental Research (NIER). (2013). Estimation on pollutant unit mass from an industrial wastewater discharging facility, National Institute of Environmental Research, 2-14. [Korean Literature]
  15. National Institute of Environmental Research(NIER). (2016). A development of water pollutants inventory for industrial wastewater for the industrial categories(III), National Institute of Environmental Research, 1-5. [Korean Literature]
  16. United States Environmental Protection Agency (U.S.EPA.). (2010). NPDES Permit Writers' Manual, United States Environmental Protection Agency, 20-35.