Abstract

Objective: The aim of this study is to consider the effect of skin tissue necrosis by improving blood flow in animal skin models for low frequency pulsed electromagnetic fields (LF_PEMF) stimulation. Methods: Twenty rats (Wistar EPM-1 male, 280-320 g) were randomly divided into control groups (n=10) and the PEMF groups (n=10). To induce necrosis of the skin tissue, skin flap was treated in the back of the rat, followed by isolation film and skin flap suturing. Subsequently, the degree of necrosis of the skin tissue was observed for 7 days. The control group did not perform any stimulation after the procedure. For the PEMF group, LF_PEMF (1 Hz, 10 mT) was stimulated in the skin flap area, for 30 minutes a day and 7 days. Cross-polarization images were acquired at the site and skin tissue necrosis patterns were analyzed. Results: In the control group, skin tissue necrosis progressed rapidly over time. In the PEMF group, skin tissue necrosis was slower than the control group. In particular, no further skin tissue necrosis progress on the day 6. Over time, a statistically significant difference from the continuous necrosis progression pattern in the control group was identified (p<0.05). Conclusions: It was confirmed that low frequency pulsed electromagnetic fields (LF_PEMF) stimulation can induce relaxation of skin tissue necrosis.

Keywords

References

  1. Khanolkar MP, Bain SC, Stephens JW. The diabetic foot. Q J Med. 2008;101:685-95. https://doi.org/10.1093/qjmed/hcn027
  2. Laing P. The development and complications of diabetic foot ulcers. Am J Surg. 1998;176:11-9. https://doi.org/10.1016/S0002-9610(98)00182-2
  3. Yarkony GM. Pressure Ulcers: A Review. Arch Phys Med Rehabil. 1994;75:908-17. https://doi.org/10.1016/0003-9993(94)90117-1
  4. Hidalgo F, Mas D, Rubio M, Garcia-Hierro P. Infections in critically ill burn patients. Medicina Intensiva. 2016;40:179-85. https://doi.org/10.1016/j.medin.2016.02.001
  5. Macedo JLS, Santos JB. Predictive factors of mortality in burn patients. Rev Inst Med trop S Paulo. 2007;49:365-70. https://doi.org/10.1590/S0036-46652007000600006
  6. Kerrigan CL. Skin flap failure: pathophysiology. Plast Reconstr Surg. 1983;72:766-77. https://doi.org/10.1097/00006534-198312000-00003
  7. Da Silva Duarte I, De Carvalho Gomes HF, Ferreira LM. Effect of dimethyl sulphoxide on necrosis of skin flaps in rats. Can J Plast Surg. 1998;6:93-7. https://doi.org/10.1177/229255039800600205
  8. Gherardini G, Lundeberg T, Cui JG, Eriksson SV, Trubek S, Linderoth B. Spinal cord stimulation improves survival in ischemic skin flaps: an experimental study of the possible mediation by calcitonin gene-related peptide. Plast Reconstr Surg. 1999;103:1221-8. https://doi.org/10.1097/00006534-199904010-00018
  9. Davis RE, Wachholz JH, Jassir D, Perlyn CA, Agrama MH. Comparison of topical anti-ischemic agents in the salvage of failing random-pattern skin flaps in rats. Arch Facial Plast Surg. 1999;1:27-32. https://doi.org/10.1001/archfaci.1.1.27
  10. Prado RP, Liebano RE, Hochman B, Pinfildi CE, Ferreira LM. Experimental model for low level laser therapy on ischemic random skin flap in rats. Acta Cir Bras. 2006;21:258-62. https://doi.org/10.1590/S0102-86502006000400013
  11. Esteves I Jr, Masson IB, Oshima CTF, Paiotti APR, Liebano RE, Plapler H. Low-level laser irradiation, cyclooxygenase-2 (COX-2) expression and necrosis of random skin flaps in rats. Lasers Med Sci. 2012;27:655-60. https://doi.org/10.1007/s10103-011-1011-1
  12. Pena-Philippides JC, Yang Y, Bragina O, Hagberg S, Nemoto E, Roitbak T. Effect of Pulsed Electromagnetic Field (PEMF) on Infarct Size and Inflammation After Cerebral Ischemia in Mice. Transl Stroke Res. 2014;5:491-500. https://doi.org/10.1007/s12975-014-0334-1
  13. Ross CL, Zhou Y, McCall CE, Soker S, Criswell TL. The Use of Pulsed Electromagnetic Field to Modulate Inflammation and Improve Tissue Regeneration: A Review. Bioelectricity. 2019;1:247-59. https://doi.org/10.1089/bioe.2019.0026
  14. Sun J, Kwan RL, Zheng Y, Cheing GL. Effects of pulsed electromagnetic fields on peripheral blood circulation in people with diabetes: a randomized controlled trial. Bioelectromagnetics. 2016;37:290-7. https://doi.org/10.1002/bem.21983
  15. Choi M, Cheung K, Li X, Cheing GL. Pulsed electromagnetic field (PEMF) promotes collagen fibre deposition associated with increased myofibroblast population in the early healing phase of diabetic wound. Arch Dermatol Res. 2016;308:21-9. https://doi.org/10.1007/s00403-015-1604-9
  16. Weber RV, Navarro A, Wu JK, Yu H, Strauch B. Pulsed magnetic fields applied to a transferred arterial loop support the rat groin composite flap. Plast Reconstr Surg. 2004;114:1185. https://doi.org/10.1097/01.PRS.0000135857.95310.13
  17. McKay JC, Prato FS, Thomas AW. A literature review: the effects of magnetic field exposure on blood flow and blood vessels in the microvasculature. Bioelectromagnetics. 2007; 28:81-98. https://doi.org/10.1002/bem.20284
  18. Xu S, Okano H, Ohkubo C. Acute effects of whole-body exposure to static magnetic fields and 50-Hz electromagnetic fields on muscle microcirculation in anesthetized mice. Bioelectrochemistry. 2001;53:127-35. https://doi.org/10.1016/S0302-4598(00)00120-3
  19. Gmitrov J. Static magnetic field and verapamil effect on baroreflex stimulus-induced microcirculatory responses. Electromagn Biol Med. 2004;23:141-55. https://doi.org/10.1081/LEBM-200040471
  20. Boas DA, Dunn AK. Laser speckle contrast imaging in biomedical optics. J Biomed Opt. 2010;15(1):011109. https://doi.org/10.1117/1.3285504
  21. Tao R, Huang K. Reducing blood viscosity with magnetic fields. Phys Rev E. 2011;84:011905. https://doi.org/10.1103/PhysRevE.84.011905
  22. Strauch B, Herman C, Dabb R, Ignarro LJ, Pilla AA. Evidencebased use of pulsed electromagnetic field therapy in clinical plastic surgery. Aesthet Surg. 2009;29:135-43. https://doi.org/10.1016/j.asj.2009.02.001
  23. Callaghan MJ, Chang EI, Seiser N, Aarabi S, Ghali S, Kinnucan ER, Simon BJ, Gurtner GC. Pulsed electromagnetic fields accelerate normal and diabetic wound healing by increasing endogenous FGF-2 release. Plast Reconstr Surg. 2008;121:130-41. https://doi.org/10.1097/01.prs.0000293761.27219.84