DOI QR코드

DOI QR Code

Study of Thermal Bridge Breaker to Prevent the Thermal Bridge Effect on Metal Panel Roofs

금속패널지붕의 열교 방지를 위한 열교차단장치 개발 및 적용효과 분석

  • Received : 2020.12.08
  • Accepted : 2020.12.22
  • Published : 2021.02.28

Abstract

To realize a zero-energy building, a technology that minimizes the energy loss due to thermal bridges by preventing their formation is emerging as an important design factor. In this study, we develop a thermal bridge breaker to prevent thermal bridging in a metal panel roof and attempt to analyze the effects of its application. To this end, we fabricated a thermal bridge breaker and analyzed it in terms of its strength and heat-transfer characteristics, in addition to conducting a load simulation. The thermal bridge prevention effect of the developed thermal bridge breaker improved the insulation performance of the metal panel roof, and the results of a cooling/heating peak load simulation performed by applying the heat transmission resistance test results to a building proved the existence of this effect.

Keywords

References

  1. Song, S. Y., "Internal insulation vs external insulation, energy saving potentials of externally insulated apartment buildings," Review of Architecture and Building Science, Vol. 58, No. 3, pp. 16-21, 2014.
  2. Shin, D. H., Kim, Y. H., and Kim, H. J., "An Experimental Study on Structural Capacities of Thermal Bridge Breaker Systems Embedded in Cantilever Slabs," Journal of Architectural Institute of Korea, Vol. 30 No. 9, pp. 31-40, 2014.
  3. Kim, Y. H., Kim, H. J. and Lee, H. Y., "Investigation and analysis of patents for the thermal bridge breaker in green buildings", Journal of The Korean Digital Architecture Interior Association, Vol. 13 No. 2, pp. 35-43, 2013.