Abstract

The high-density fiber composite manufacturing method by the extrusion molding method has the characteristic that continuous production is possible, and the product is molded through a mold forming a specific cross-section. OPC is used as a defect material, an appropriate amount of SiO2 is supplied for CaO reaction activity, and high density and high strength are expressed through steam and autoclave curing. However, due to the use of organic reinforcing fibers, the flame duration exceeds the regulations during the non-combustible performance test, making it difficult to secure performance. In this study, the product was produced by mixing alkali-resistant organic fiber and fly ash having voids as a binder by replacing the existing polypropylene fiber. appeared to be possible.

진공 압출성형 방법에 의하여 생산되는 섬유 시멘트 복합체는 연속 생산이 가능하고 고밀도 무기질 재료의 구성이 가능한 제품이다. 보강섬유로 사용하고 있는 폴리프로필렌과 펄프의 연소에 따른 가스의 발생과 이로 인하여 불연성능 시험 중 중심부에 지속적으로 불꽃이 발생하여 성능을 충족하지 못하는 경우가 발생한다. 본 연구에서는 불연 특성 개선을 위하여 내알칼리 성능을 개선한 ARG(Alkali resistant glass)섬유를 보강섬유로 사용하여 시험체를 제조하고 성능 평가를 실시하였다. 섬유량은 부피비를 기준으로 하여 적용하였다. 측정결과 폴리프로필렌을 전량 유리섬유로 대체하고 펄프 사용량을 50% 감소하여 배합할 경우 불꽃은 발생하지 않거나 5초 이내 소화 되는 것을 확인하였다. 패널의 압출성과 생산성, 그리고 경화 후 적정한 인성 및 취성재료의 개선을 위하여 펄프 사용량은 기존 사용량의 50%를 유지하는 것이 바람직하며, 불연성능의 개선을 위하여 별도의 결합재 변경은 필요하지 않은 것으로 확인되었다.

Keywords

Acknowledgement

본 연구는 한국건설기술연구원 "선진화국가 수출 경쟁력 확보를 위한 압출성형 패널 내열성 향상 기술개발(과제번호 20210377-001)"에 의해 수행되었습니다.

References

  1. James, S.R. (1996). Principles of Ceramics Processing, John Wiley & Sons, INS.
  2. Jang, B.K. (1998). Cement Materials Science, Chonnam National University Press [in Korean].
  3. Kadashevich, I., Schneider, H.J., Stoyan, D. (2005). Statistical modeling of the geometrical structure of the system of artificial air pores in autoclaved aerated concrete, Cement and Concrete Research, 35(8), 1495-1502. https://doi.org/10.1016/j.cemconres.2004.10.010
  4. Karakurt, C., Kurama, H., Topcu, I.B. (2010). Utilization of natural zeolite in aerated concrete production, Cement and Concrete Composites, 32(1), 1-8. https://doi.org/10.1016/j.cemconcomp.2009.10.002
  5. Kim, Y.H. (2011). Strength characteristics according to the mixed CaO/SiO2 ratio to autoclaved aerated concrete(AAC) used on the exterior panel in buildings, Journal of The Korean Digital Architecture.Interior Association, 11(3), 35-52 [in Korean].
  6. Kim, Y.H., Song, T.H., Lee, S.H. (2011). The curing characterization by crushed stone-powder replacement ratio of extrusion concrete panel, Architectural Institute of Korea, 31(2), 287-288 [in Korean].
  7. Park, J.S., Song, T.H., Jeon, C.S. (2012). A study on the physical characteristic changes of high density cement complex using crushed stone powder from quarry, Journal of Korea Society of Waste Management, 29(8), 751-759 [in Korean]. https://doi.org/10.9786/kswm.2012.29.8.751
  8. Song, T.H., Lee, S.H., Kim, Y.H. (2011a). Changes in physical properties depending on curing conditions of extruded cement mixture with crushed stone powder, Journal of the Architectural Institute of Korea Structure & Construction, 27(8), 97-104 [in Korean].
  9. Song, T.H., Park, J.S., Lee, S.H. (2011b). An experimental study on the fire-resistant performance of eco-friendly extruding concrete panel, Journal of the Architectural Institute of Korea Structure & Construction, 27(12), 123-130 [in Korean].
  10. Taylor, H.F.W. (1964). Hydration of Portland Cement, Cement Chemistry.