References
- AIK (2018), Site Inspection and Damage Investigation of Buildings by Earthquakes in Gyeongju and Pohang, Architectural Institute of Korea, Seoul, Korea. (In Korean)
- ASTM C 1314 (2007), Standard Test Method for Compressive Strength of Masonry Prisms, ASTM International, Philadelphia, USA.
- ASTM E 519 (2003), Standard Test Method for Diagonal Tension(Shear) in Masonry Assemblages, ASTM International, Philadelphia, USA.
- Bhattacharya, S., Nayak S., and Dutta, S. C. (2014), A critical review of retrofitting methods for unreinforced masonry structures, International Journal of Disaster Risk Reduction, 7, 51-67. https://doi.org/10.1016/j.ijdrr.2013.12.004
- Capozucca, R. (2011), Experimental analysis of historic masonry walls reinforced by CFRP under in-plane cyclic loading, Composite Structures, 94(1), 277-289. https://doi.org/10.1016/j.compstruct.2011.06.007
- Chang, K. K., and Seo, D. W.(2011), Present State and Necessity of Seismic Design for Low-rise Masonry Buildings in Korea, Special Issue, Review of Architecture and Building Science, 55(5), 45-50.
- Darbhanzi, A., Marefat, M. S., and Khanmohammadi, M. (2014), Investigation of in-plane seismic retrofit of unreinforced masonry walls by means of vertical steel ties, Construction and Building Materials, 52, 122-129. https://doi.org/10.1016/j.conbuildmat.2013.11.020
- FEMA 356 (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings. FEMA, Washington.
- Hwang, S. H., Yang, K. H., and Kim, S. H.(2020), Evaluation on Seismic Performance of Masonry Walls Strengthened with Unbonded Steel-Bar Truss Systems, Journal of the Korea Concrete Institute, Accepted. (In Korean)
- Ismail N and Ingham JM (2012), Cyclic out-of-plane behavior of slender clay brick masonry walls seismically strengthened using posttensioning. Journal of Structural Engineering, 138(10), 1255-1266. https://doi.org/10.1061/(asce)st.1943-541x.0000565
- KCS 41 34 02 (2018), Brick Construction. Korea Construction Standard Center. (In Korean)
- KCS 41 46 02 (2018), Cement Mortar Coat. Korea Construction Standard Center. (In Korean)
- KS B 0802 (2018), Method of Tensile Test for Metallic Materials, KSA, Seoul, Korea. (In Korean)
- KS F 4004 (2013), Concrete Bricks, KSA, Seoul, Korea. (In Korean)
- Lee, J. H. (2005), Seismic Capacity and Seismic Retrofitting of Low Rise Buildings Unreinforced Masonry, Brick-infilled RC Frame and Steel Slit Damper Retrofitted RC Frame. Ph.D. Thesis. Kwangwoon University. (in Korean)
- NIDP (2009), Study on Seismic Retrofitting Techniques for Unreinforced Masonry Buildings, National Emergency Management Agency, Seoul, Korea. (In Korean)
- Popa, V., Pascu, R., Papurcu, A., and Albota, E. (2016) Retrofitting of squat masonry walls by FRP grids bonded by cement-based mortar, Earthquakes and Structures, 10(1), 125-139. https://doi.org/10.12989/eas.2016.10.1.125
- Rinaldin, G., Amadio, C., and Gattesco N. (2017), Review of experimental cyclic tests on unreinforced and strengthened masonry spandrels and numerical modelling of their cyclic behavio", Engineering and Structures, 132, 609-623. https://doi.org/10.1016/j.engstruct.2016.11.063
- Yang, K. H., Joo, D. B., Sim, J. I., and Kang, J. H. (2012), In-plane seismic performance of unreinforced masonry walls strengthened with unbonded prestressed wire rope units, Engineering and Structures, 45, 449-459. https://doi.org/10.1016/j.engstruct.2012.06.017
- Yang, K. H., Mun, J. H., and Hwang, S. H. (2020), Cyclic Shear Behavior of Masonry Walls Strengthened with Prestressed Steel Bars and Glass Fiber Grids, Composite Structures, 238, 1-12.