초음파와 자외선(UV) 동시 적용이 가정용 가습기 내 살균에 미치는 시너지 효과에 대한 반응속도론적 연구

Kinetic examination on synergistic effect of co-use of ultrasonic wave and ultraviolet radiation on bacterial disinfection in a household humidifier

  • 김성아 (연세대학교 건설환경공학과) ;
  • 김지현 (연세대학교 건설환경공학과) ;
  • 이민주 (연세대학교 건설환경공학과) ;
  • 김자연 (연세대학교 건설환경공학과) ;
  • 정우식 (연세대학교 건설환경공학과) ;
  • 박준홍 (연세대학교 건설환경공학과)
  • Kim, Seunga (Department of Civil and Environmental Engineering, Yonsei University) ;
  • Kim, Jihyun (Department of Civil and Environmental Engineering, Yonsei University) ;
  • Lee, Minjoo (Department of Civil and Environmental Engineering, Yonsei University) ;
  • Kim, Jayun (Department of Civil and Environmental Engineering, Yonsei University) ;
  • Jung, Woosik (Department of Civil and Environmental Engineering, Yonsei University) ;
  • Park, Joonhong (Department of Civil and Environmental Engineering, Yonsei University)
  • 투고 : 2021.04.09
  • 심사 : 2021.06.15
  • 발행 : 2021.06.15

초록

This study examined the effect of ultraviolet (UV) application on bacterial disinfection in a commercialized humidifier using ultrasonic wave (UW). To accurately examine disinfection kinetics in tap-water condition, tap-water was sterilized using a filter, and then inoculated with pure cultures of E. coli and P. putida with known viable counts. The disinfection kinetic characteristics were experimentally compared when UV alone, UW alone, and UW+UV together were applied in disinfecting the added bacteria in the commercialized humidifier. When UV alone was applied, bacterial disinfection kinetics followed a first-order decay reaction, and showed an approximately 10-time weaker disinfection compared to the typical UV disinfection in water treatment or wastewater treatment. When UW alone was applied, bacterial disinfection kinetics followed a second-order decay reaction with a low disinfection rate constant of 0.0002 min-1(CFU/mL)-1. When UV and UW were applied together, however and interestingly, the disinfection rate constant (0.0211 min-1(CFU/mL)-1) was approximately 100 times increased than that for the UW alone case. These results revealed that the co-use of UV and UW can provide synergistic effect on bacterial disinfection in a tap-water condition in household humidifiers.

키워드

과제정보

본 연구는 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업 (No. 2018R1A6A1A08025348)과 환경부의 재원으로 한국환경산업기술원의 상하수도혁신기술개발사업의 지원(2020002700003)을 받아 연구되었습니다.

참고문헌

  1. Baur, X., Behr, J., Dewair, M., Ehret, W., Fruhmann, G., Vogelmeier, C., Weiss, W. and Zinkernagel, V. (1988). Humidifier lung and humidifier fever, Lung, 166(1), 113-124. https://doi.org/10.1007/BF02714035
  2. Byeon, J.E., Kim, H.S., Park, M.Y., Lee, K.M., Hong, M.G., and Choi, Y.Y. (2020). An estimation of population at risk of exposure to humidifier disinfectant and associated health effects, J. Environ. Health Sci., 46(4), 457-469. https://doi.org/10.5668/JEHS.2020.46.4.457
  3. Hwang, D.G., Chon, J.W., Kim, H.S., Kim, H.S., Kim, D.H., Song, K.Y., Yim, J.H., Kim, Y.J., Kang, I.B., and Seo, K.H. (2015). Rapid detection of viable Cronobacter sakazakii using propidium monoazide(PMA) in combination with real-time qPCR, J. Milk Sci. Biotechnol., 33(3), 197-202.
  4. Jang, I.S., and Kim, J.Y. (2005). UV irradiation for water disinfection, J. Korean Inst. Illum. Electr. Install. Eng., 19(5), 14-21.
  5. Kim, D.S., Song, S.K., and Park, Y.S. (2010). A comparison of single disinfection process for inactivation of E.coli, Korean Soc. Biotechnol. Bioeng. J., 25(1), 25-32.
  6. Kim, K.W., Ahn, K., Yang, H. J., Lee, S., Park, J.D., Kim, W.K., Kim, J.T., Kim, H.H., Rha, Y.H., Park, Y.M., Sohn, M.H., Oh, J.W., Lee, H.R., Lim, D.H., Choung, J.T., Han, M.Y., Lee, E., Kim, H.Y., Seo, J.H., Kim, B.J., Cho, Y.A., Do, K.H., Kim, S.A., Jang, S.J., Lee, M.S., Kim, H.J., Kwon, G.Y., Park, J.H., Gwack, J., Youn, S.K., Kwon, J.W., Jun, B.Y., Pyun, B.Y., and Hong, S.J. (2014). Humidifier disinfectant-associated children's interstitial lung disease, Am. J. Respir. Crit. Care Med., 189(1), 48-56. https://doi.org/10.1164/rccm.201306-1088OC
  7. Li, D., Tong, T., Zeng, S., Lin, Y., Wu, S., and He, M. (2014). Quantification of viable bacteria in wastewater treatment plants by using propidium monoazide combined with quantitative PCR (PMA-qPCR), J. Environ. Sci., 26(2), 299-306. https://doi.org/10.1016/S1001-0742(13)60425-8
  8. Lee, E.S., Lee, M.Y., and Han, S.H. (2006). "Detection and occurrence of mycobacteria in water supplies", Proceedings of Korean Society on Water Environment and Korean Society of Water and Wastewater Joint Spring Conference, 21-22 April, 2006, Korean Society on Water Environment, Incheon, Korea.
  9. Lee, J.Y., Kim, Y.T., and Lee, T.J. (2005). "WTP UV disinfection system", Proceedings of the KFMA Annual Meeting, Korean Society for Fluid Machinery, 126-132.
  10. Ministry of Food and Drug Safety (MFDS). (2019). www.foodsafetykorea.go.kr/foodcode/01_03.jsp?idx=362 (April 01, 2021).
  11. National Institute of Environmental Research (NIER). (2021). The standard of official water quality testing of drinking water, http://www.law.go.kr/DRF/lawService.do?OC=me_pr&target=admrul&ID=2100000198017&type=HTML&mobileYn= (April 03, 2021)
  12. Nocker, A., Sossa, K.E., and Camper, A.K. (2007). Molecular monitoring of disinfection efficacy using propidium monoazide in combination with quantitative PCR, J. Microbiol. Methods, 70, 252-260. https://doi.org/10.1016/j.mimet.2007.04.014
  13. Park, D.U. (2013). Review of humidifier lung cases caused by use of humidifier -focusing on probable environmental causal agents, J. Environ. Health Sci., 39(2), 105-116. https://doi.org/10.5668/JEHS.2013.39.2.105
  14. Park J.I., Lee, Y., Kim, K.H., Lee, T.H., Park, C.J., and Yoo, J.H. (2019). A prediction on the improvement of disinfection efficiency and optimal operation of residual chlorine in water distribution line by application of UV process in I WTP, J. Korean Soc. Environ. Eng., 41(11), 597-610. https://doi.org/10.4491/KSEE.2019.41.11.597
  15. Rattanakul, S. and Oguma, K. (2018). Inactivation kinetics and efficiencies of UV-LEDs against Pseudomonas aeruginosa, Legionella pneumophila, and surrogate microorganisms, Water Res., 130, 31-37. https://doi.org/10.1016/j.watres.2017.11.047
  16. Sohn, J.R., and Ryu, B.S. (1999). Disinfection of water by ultrasonic irradiation, Korean J. Sanitation, 14(1), 54-61.
  17. Varma, M., Field, R., Stinson, M., Rukovets, B., Wymer, L., and Haugland, R. (2009). Quantitative real-time PCR analysis of total and propidium monoazide-resistant fecal indicator bacteria in wastewater, Water Res., 43(19), 4790-4801. https://doi.org/10.1016/j.watres.2009.05.031