DOI QR코드

DOI QR Code

Subtractive versus additive indirect manufacturing techniques of digitally designed partial dentures

  • Snosi, Ahmed Mamdouh (Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, British University) ;
  • Lotfy, Shaimaa Mohamed (Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University) ;
  • Thabet, Yasmine Galaleldin (Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University) ;
  • Sabet, Marwa Ezzat (Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University) ;
  • Rizk, Fardos Nabil (Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, British University)
  • 투고 : 2021.06.26
  • 심사 : 2021.09.24
  • 발행 : 2021.10.30

초록

PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of digitally designed removable partial denture (RPD) frameworks, constructed by additive and subtractive methods castable resin patterns, using comparative 3D analysis. MATERIALS AND METHODS. A Kennedy class III mod. 1 educational maxillary model was used in this study. The cast was scanned after modification, and a removable partial denture framework was digitally designed. Twelve frameworks were constructed. Two groups were defined: Group A: six frameworks were milled with castable resin, then casted by the lost wax technique into Co-Cr frameworks; Group B: six frameworks were printed with castable resin, then casted by the lost wax technique into Co-Cr frameworks. Comparative 3D analysis was used to measure the accuracy of the fabricated frameworks using Geomagic Control X software. Student's t-test was used for comparing data. P value ≤ .05 was considered statistically significant. RESULTS. Regarding the accuracy of the occlusal rests, group A (milled) (0.1417 ± 0.0224) showed significantly higher accuracy than group B (printed) (0.02347 ± 0.0221). The same results were found regarding the 3D comparison of the overall accuracy, in which group A (0.1501 ± 0.0205) was significantly more accurate than group B (0.179 ± 0.0137). CONCLUSION. In indirect fabrication techniques, subtractive manufacturing yields more accurate RPDs than additive manufacturing.

키워드

참고문헌

  1. Preshaw PM, Walls AW, Jakubovics NS, Moynihan PJ, Jepson NJ, Loewy Z. Association of removable partial denture use with oral and systemic health. J Dent 2011;39:711-9. https://doi.org/10.1016/j.jdent.2011.08.018
  2. Viswambaran M, Sundaram RK. Effect of storage time and framework design on the accuracy of maxillary cobalt-chromium cast removable partial dentures. Contemp Clin Dent 2015;6:471-6. https://doi.org/10.4103/0976-237X.169841
  3. Benso B, Kovalik AC, Jorge JH, Campanha NH. Failures in the rehabilitation treatment with removable partial dentures. Acta Odontol Scand 2013;71:1351-5. https://doi.org/10.3109/00016357.2013.777780
  4. Dunham D, Brudvik JS, Morris WJ, Plummer KD, Cameron SM. A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies. J Prosthet Dent 2006;95:323-6. https://doi.org/10.1016/j.prosdent.2006.02.001
  5. Campbell SD, Cooper L, Craddock H, Hyde TP, Nattress B, Pavitt SH, Seymour DW. Removable partial dentures: The clinical need for innovation. J Prosthet Dent 2017;118:273-80. https://doi.org/10.1016/j.prosdent.2017.01.008
  6. Kanazawa M, Inokoshi M, Minakuchi S, Ohbayashi N. Trial of a CAD/CAM system for fabricating complete dentures. Dent Mater J 2011;30:93-6. https://doi.org/10.4012/dmj.2010-112
  7. Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014;2014:783948. https://doi.org/10.1155/2014/783948
  8. Stansbury JW, Idacavage MJ. 3D printing with polymers: challenges among expanding options and opportunities. Dent Mater 2016;32:54-64. https://doi.org/10.1016/j.dental.2015.09.018
  9. Moraru E, Besnea D, Dontu O, Gheorghe GI, Constantin V. Applications of additive technologies in realization of customized dental prostheses. In: Gheorghe GI, editor. Lecture notes in networks and systems. Cham: Springer International Publishing; 2019. p. 8-17.
  10. Hyndman RJ, Koehler AB. Another look at measures of forecast accuracy. Int J Forecast 2006;22:679-88. https://doi.org/10.1016/j.ijforecast.2006.03.001
  11. Arnold C, Hey J, Schweyen R, Setz JM. Accuracy of CAD-CAM-fabricated removable partial dentures. J Prosthet Dent 2018;119:586-92. https://doi.org/10.1016/j.prosdent.2017.04.017
  12. Soltanzadeh P, Suprono MS, Kattadiyil MT, Goodacre C, Gregorius W. An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks. J Prosthodont 2019;28:547-55. https://doi.org/10.1111/jopr.12997
  13. Tregerman I, Renne W, Kelly A, Wilson D. Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent 2019;122:390-5. https://doi.org/10.1016/j.prosdent.2018.10.013
  14. Eggbeer D, Bibb R, Williams R. The computer-aided design and rapid prototyping fabrication of removable partial denture frameworks. Proc Inst Mech Eng H 2005;219:195-202. https://doi.org/10.1243/095441105X9372
  15. Tasaka A, Kato Y, Odaka K, Matsunaga S, Goto TK, Abe S, Yamashita S. Accuracy of clasps fabricated with three different CAD/CAM technologies: casting, milling, and selective laser sintering. Int J Prosthodont 2019;32:526-9. https://doi.org/10.11607/ijp.6363
  16. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56. https://doi.org/10.1016/j.prosdent.2016.02.017
  17. Kalberer N, Mehl A, Schimmel M, Muller F, Srinivasan M. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness. J Prosthet Dent 2019;121:637-43. https://doi.org/10.1016/j.prosdent.2018.09.001
  18. Bae EJ, Jeong ID, Kim WC, Kim JH. A comparative study of additive and subtractive manufacturing for dental restorations. J Prosthet Dent 2017;118:187-93. https://doi.org/10.1016/j.prosdent.2016.11.004
  19. Tasaka A, Shimizu T, Kato Y, Okano H, Ida Y, Higuchi S, Yamashit S. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering. J Prosthodont Res 2020;64:224-30. https://doi.org/10.1016/j.jpor.2019.07.009
  20. Ortorp A, Jonsson D, Mouhsen A, Vult von Steyern P. The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 2011;27:356-63. https://doi.org/10.1016/j.dental.2010.11.015