DOI QR코드

DOI QR Code

Gas-Solid Heat Transfer Analysis of Bubbling Fluidized Bed at Bottom Ash Cooler

바닥재 냉각기 기포유동층의 기체-고체 연전달 분석

  • Gyu-Hwa, Lee (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Dongwon, Kim (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Jong-min, Lee (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Kyoungil, Park (KEPCO Research Institute, Korea Electric Power Corporation) ;
  • Byeongchul, Park (KEPCO Research Institute, Korea Electric Power Corporation)
  • Received : 2020.12.12
  • Accepted : 2021.04.01
  • Published : 2022.12.30

Abstract

In this study we investigated the gas to solid heat transfer of bubbling fluidized bed bottom ash cooler installed at the Donghae power plant in South Korea. Several different analyses are done through 1-D calculations and 3-D CFD simulation to predict the bottom ash exit temperatures when it exits the ash cooler. Three different cases are set up to have consideration of unburnt carbon in the bottom ash. Sensible heat comparison and heat transfer calculation between the fluidization air and the bottom ash are conducted and 3-D CFD analysis is done on three cases. We have obtained the results that the bottom ash with unburnt carbon is exiting the ash cooler, exceeding the targeted temperature from both 1-D calculation and 3-D CFD simulation.

Keywords

References

  1. Kothari, A.K., M.S. thesis, Illinois Institute of Technology, 1967
  2. Lee, J.M., Kim, D.W., Park K.I. and Kim S.M., "Performance analysis of cyclone and fludized bed external heat exchanger through Barracuda simulation", 23th International Conference on FBC, Spring, Korea, 1171-1177, 2018
  3. Williams A. K., "Industrial applications of CFD for clean coal plant design", NETL Workshop on Multiphase Flow Science, August, USA, 2013
  4. Wen, C. and Yu, Y., "Mechanics of fluidization", Chemical Engineering Progress Symposium, 100-111, 1966
  5. Ergun, S., "Fluid flow through packed columns", Chemical Engineering Progress, 48-89, 1949