DOI QR코드

DOI QR Code

Development of Automatic Reading System for Steam Sterilization Indicator

스팀 멸균지시제 자동판독시스템 개발

  • 송혁 (을지대학교 생체의과학융합대학원) ;
  • 김정래 (을지대학교 생체의과학융합대학원) ;
  • 이우철 (을지대학교 의료공학과)
  • Received : 2022.06.14
  • Accepted : 2022.08.17
  • Published : 2022.08.31

Abstract

The color change of the success of the steam sterilization indicator used in steam sterilization is currently being read by relying on the human eye. The result of color change on the success of sterilization can only be accurately read and judged by trained personnel. Developed an automatic reading system for steam sterilization indicators for the current human-dependent system, and developed an automatic reading device system for reading methods that were previously relied on with the human eye to develop a system that is more accurate and easier for anyone to read.

스팀멸균에서 사용되는 스팀 멸균지시제(Steam sterilization Indicator)의 색변화 성공여부를 현재는 사람의 눈을 의존해서 판독하고 있다. 멸균의 성공여부에 대한 색변화의 결과는 숙련된 훈련을 받은 사람만이 정확하게 판독해서 판정을 내릴 수 있다. 스팀 멸균지시제에 대한 자동 판독시스템을 개발하여 기존 인간의 눈으로 의존해서 판독했던 방식을 기존보다 정확하고, 누구나 쉽게 판독하는 시스템을 개발하였다.

Keywords

Acknowledgement

본 논문은 2020년도 주식회사 챔버 기술연구소에서 중소벤처기업부의 중소기업기술혁신지원사업의 지원으로 수행되었슴.

References

  1. International Std. ISO11140-1, Sterilization of health care products - Chemical indicators - Part 1: General products - Chemical indicators - Part 3: Class, International Standard, 2014.
  2. International Std. ISO11140-3, Sterilization Of Health Care Product, - Chemical Indicators - Part 3: Class 2 Indicator Systems For Use In the Bowie And Dick-Type Steam Penetration Test, International Standard, 2007.
  3. International Std. ISO11140-4, Sterilization Of Health Care Products - Chemical Indicators - Part 4: Class 2 Indicator Systems For Use In the Bowie And Dick-Type Steam Penetration Test, International Standard, 2007.
  4. International Std. ISO11140-5, Sterilization Of Health Care Products - Chemical Indicators - Part 4: Class 2 Indicator Systems For Use In the Bowie And Dick-Type Steam Penetration Test, International Standard, 2007.
  5. iTch Std, EN285, Sterilization. Steam sterilizers. Large sterilizers, 2015.
  6. iTch Std, EN285, Sterilization. Steam sterilizers, Large sterilizers, 2014.
  7. I. Mazumdar, R. Mondal, and S. Pal, "Design and Development of a Low Cost Colour Sensor and its application in Angular Position Control system of a Stepper Motor," International J. of Electronics and Computer Science Engineering, vol. 2, no. 4, 2005, pp. 1241-1251.
  8. C. Lee, T. Montvillle, and A. Sinskey "Comparison of the Efficacy of Steam Sterilization Indicators," Appl Environ Microbiol, vol. 37, no. 6, 1979, pp. 1113-1117. https://doi.org/10.1128/aem.37.6.1113-1117.1979
  9. International Std. ISO11140-1, Sterilization Of Health Care Products - Chemical Indicators - Part 1: General Requirements, American National Standard. 2005.
  10. R Puttaiah, J. Griggs, and M. D'Onofrio, "A Preliminary Evaluation of a Reusable Digital Sterilization Indicator Prototype," the J. of Contemporary Dental Practice, vol. 15, no. 5, 2014, pp 626-635. https://doi.org/10.5005/jp-journals-10024-1591
  11. P. Schneider, "Evaluation of a new rapid readout biological indicator for use in 132℃ and 135℃ vacuum-assisted steam sterilization cycles," Am J. Infect Control, vol. 42, no. 2, 2014, pp. e17-e21. https://doi.org/10.1016/j.ajic.2013.09.015
  12. J. Choi, "PID Controled UAV Monitoring System for Fire-Event Detection," J. of the KIECS, vol. 15, no. 1, 2020, pp. 1-8.
  13. J. Lim, N. Park, B. Choi, Y. Kim, and J. Kim, "A Study on the Multi-sensor Toilet," J. of the KIECS, vol. 17, no. 1, 2022, pp. 201-200.