DOI QR코드

DOI QR Code

3D printed interim immediate denture by using the occlusal plane digital transfer method of the POP BOW system in a patient planning to extract upper and lower residual teeth: a case report

상하악 전악 발거 환자에서 POP BOW 시스템의 교합평면 디지털 전이법을 이용한 3D 프린팅 임시 즉시의치의 수복 증례

  • Park, Do-Hyun (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute) ;
  • Bae, Eun-Bin (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute) ;
  • Jung, In-Hwan (Central Dental Laboratory, Pusan National University Dental Hospital) ;
  • Jeong, Chang-Mo (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute) ;
  • Yun, Mi-Jung (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute) ;
  • Huh, Jung-Bo (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute) ;
  • Lee, So-Hyoun (Department of Prosthodontics, School of Dentistry, Pusan National University, Pusan National University Dental Hospital, Dental Research Institute)
  • 박도현 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소) ;
  • 배은빈 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소) ;
  • 정인환 (부산대학교 치과병원 중앙기공실) ;
  • 정창모 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소) ;
  • 윤미정 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소) ;
  • 허중보 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소) ;
  • 이소현 (부산대학교 치의학전문대학원 치과보철학교실, 부산대학교 치과병원 치의학연구소)
  • Received : 2022.09.04
  • Accepted : 2022.09.06
  • Published : 2022.09.30

Abstract

Interim immediate denture is fabricated to minimize the period of edentulousness after removal of the patient's remaining teeth and before delivery of final prosthesis. In the case of using the CAD/CAM system, there is an advantage in that the manufacturing process in the clinic and laboratory can be simplified by overcoming some of the limitations of manufacturing interim immediate dentures in the traditional way. However, there are also disadvantages in that errors occur in the process of transmitting information about the patient's intermaxillary relationship to the digital network of the laboratory, resulting in unstable occlusal relationships or non-esthetic prostheses. To overcome this problem, using the simple and accurate POP BOW system's occlusal plane digital transfer method, it was possible to fabricate an esthetic and functional 3D printed interim immediate denture after removal of the remaining upper and lower anterior teeth.

모든 잔존치의 발거를 계획한 환자의 경우 최종 보철 제작 전 무치악으로 지내는 기간을 최소화하기 위해 미리 임시 즉시 의치를 제작하게 된다. CAD/CAM 시스템을 이용하면 전통적 방식에서의 한계점들을 보완하여 진료실과 기공실에서의 제작 과정을 간소화 시킬 수 있다는 장점이 있다. 하지만, 환자의 악간관계에 관한 정보를 정확하게 기공실의 디지털 네트워크로 전달하는 과정에서 오차가 발생하여 교합관계가 불안정하거나 비심미적인 보철물이 제작될 빈도가 높다는 단점도 있다. 이러한 문제점을 극복하기 위해 간단하고 정확한 POP BOW 시스템의 교합평면 디지털 전이법을 이용하여, 상하악 전치부 잔존치 발거 후 심미적이고 기능적인 3D 프린팅 임시 즉시의치를 장착한 환자의 성공적인 증례를 보고하고자 한다.

Keywords

Acknowledgement

본 연구는 2022년도 부산대학교 치과병원 임상연구비 지원으로 이루어졌음.

References

  1. The Korean Academy of Prosthodontics. The glossary of prosthodontic terms. 4th ed. Seoul; Dental and Medical Publishing; 2020.
  2. Heartwell CM Jr, Salisbury FW. Immediate complete dentures: an evaluation. J Prosthet Dent 1965;15:615-24. https://doi.org/10.1016/0022-3913(65)90031-4
  3. Appelbaum MB. The practical dynamics of the interim denture concept: a comparison with the conventional immediate denture technique. J Am Dent Assoc 1983;106:826-30. https://doi.org/10.14219/jada.archive.1983.0438
  4. Waltz ME. Considerate postoperative care for immediate denture patients. J Prosthet Dent 1966;16:822-8. https://doi.org/10.1016/0022-3913(66)90004-7
  5. Bruce RW. Immediate denture service designed to preserve oral structures. J Prosthet Dent 1966;16:811-21. https://doi.org/10.1016/0022-3913(66)90003-5
  6. Lin HK, Pan YH, Salamanca E, Lin YT, Chang WJ. Prevention of bone resorption by HA/β-TCP + collagen composite after tooth extraction: A case series. Int J Environ Res Public Health 2019;16:4616. https://doi.org/10.3390/ijerph16234616
  7. Mangano F, Gandolfi A, Luongo G, Logozzo S. Intraoral scanners in dentistry: a review of the current literature. BMC Oral Health 2017;17:149. https://doi.org/10.1186/s12903-017-0442-x
  8. Kim NH, Kim JE, Oh KC, Chung MK, Moon HS. Fabrication of immediate complete denture using Campagna tray technique. J Korean Acad Prosthodont 2017;55:331-5. https://doi.org/10.4047/jkap.2017.55.3.331
  9. Lee SH. 3D printed interim immediate denture by using the occlusal plane digital transfer method of the POP BOW system in a mandibulectomy patient: A case report. J Digit Dent 2021;12:1-10.
  10. Kim MJ, Kim KH, Yeo DH. Fabrication of computer-aided design/computer-aided manufacturing complete denture and conventional complete denture: case report. J Dent Rehabil Appl Sci 2016;32:141-8. https://doi.org/10.14368/jdras.2016.32.2.141
  11. Roessler DM. Complete denture success for patients and dentists. Int Dent J 2003;53(5 Suppl):340-5. https://doi.org/10.1111/j.1875-595X.2003.tb00908.x
  12. Seals RR Jr, Kuebker WA, Stewart KL. Immediate complete dentures. Dent Clin North Am 1996;40:151-67. https://doi.org/10.1016/S0011-8532(22)00168-9
  13. You SM, You SG, Kang SY, Bae SY, Kim JH. Evaluation of the accuracy (trueness and precision) of a maxillary trial denture according to the layer thickness: An in vitro study. J Prosthet Dent 2021;125:139-45. https://doi.org/10.1016/j.prosdent.2019.12.014
  14. Peng CC, Chung KH, Yau HT, Ramos V Jr. Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods. J Prosthet Dent 2020;123:514-22. https://doi.org/10.1016/j.prosdent.2019.02.024
  15. Wimmer T, Eichberger M, Lumkemann N, Stawarczyk B. Accuracy of digitally fabricated trial dentures. J Prosthet Dent 2018;119:942-7. https://doi.org/10.1016/j.prosdent.2017.06.020
  16. Park ME, Shin SY. Three-dimensional comparative study on the accuracy and reproducibility of dental casts fabricated by 3D printers. J Prosthet Dent 2018;119:861.e1-7.
  17. Wang C, Shi YF, Xie PJ, Wu JH. Accuracy of digital complete dentures: A systematic review of in vitro studies. J Prosthet Dent 2021;125:249-56. https://doi.org/10.1016/j.prosdent.2020.01.004
  18. Dimitrova M, Corsalini M, Kazakova R, Vlahova A, Chuchulska B, Barile G, Capodiferro S, Kazakov S. Comparison between conventional PMMA and 3D printed resins for denture bases: A narrative review. J Compos Sci 2022;6:87. https://doi.org/10.3390/jcs6030087
  19. Kihara H, Hatakeyama W, Komine F, Takafuji K, Takahashi T, Yokota J, Oriso K, Kondo H. Accuracy and practicality of intraoral scanner in dentistry: A literature review. J Prosthodont Res 2020;64:109-13. https://doi.org/10.1016/j.jpor.2019.07.010
  20. Park JH, Cho IH, Shin SY, Choi YS. The treatment of an edentulous patient with DENTCATM CAD/CAM denture. J Korean Acad Prosthodont 2015; 53:19-25. https://doi.org/10.4047/jkap.2015.53.1.19
  21. Bolouri A. Double-custom tray procedure for immediate dentures. J Prosthet Dent 1977;37:344-8. https://doi.org/10.1016/0022-3913(77)90078-6
  22. Kwon KR. Kwon HB, Kim MJ, Kim HJ, Moon HS, Park SW, Park CJ, Song KY, Lee JS, Lee JH, Lee CH, Lim YJ, Chung MK, Chung CH, Jeong CM, Cho IH, Cho HW, Han CH. Prosthodontic treatment for edentulous patients. 2nd ed. Seoul; Dental Wisdom; 2014. p. 130-7.
  23. Duqum I, Powers KA, Cooper L, Felton D. Denture adhesive use in complete dentures: clinical recommendations and review of the literature. Gen Dent 2012;60:467-77.