Abstract

This study investigated the structural performance of wire-integrated steel decks with varied lattice end support conditions through finite element analysis. The results indicated that the steel decks with the lattice foots positioned above the supporting structural member have the higher system stiffness compared to the cases with the lattice foots shifted away from the support. It is also observed that the contribution of the end vertical bars on both the system stiffness and the strength is negligible when the lattice foots are located on the support. It is, especially, revealed that the end vertical bars can be eliminated when the lattice foot length is not smaller than 40mm. The ultimate load-carrying capacity of the system is not significantly affected by the lattice end support condition. The failure mode of the system is the top bar buckling at the center of the deck plate, the lattice end buckling, and the combination of both depending of design intention.

본 연구에서는 다양한 래티스 단부 지점조건을 갖는 철선일체형 데크플레이트의 구조성능을 유한요소해석을 통하여 평가하였다. 해석결과, 래티스 단부에서 풋의 위치가 지점부 구조부재 위에 위치하는 경우가 그렇지 않은 경우에 비해 시스템 강성이 더 큰 것으로 나타났다. 또한 래티스 풋이 지점부에 위치하는 경우, 단부 직봉이 전체 데크플레이트 시스템의 강성과 강도에 미치는 영향은 무시할 정도로 작았다. 특히 래티스 풋의 길이가 40mm 보다 작지 않을 때에는 단부 직봉이 설치되지 않아도 무방한 것으로 평가되었다. 래티스 단부 지지형상이 데크플레이트 시스템의 최대 하중저항 성능에 미치는 영향은 크지 않은 것으로 조사되었고, 시스템의 파괴모드는 설계의도에 따라 데크플레이트 중앙에서 상부 주철근의 좌굴, 래티스 단부 좌굴, 또는 이들의 조합으로 나타났다.

Keywords

Acknowledgement

이 연구는 2022년도 데크플레이트 전문 산업체인 (주)윈하이텍의 지원으로 수행하였습니다.

References

  1. ABAQUS. (2022), ABAQUS/CAE users' guide, Ver. 6.24, Dassaults Systems Simulia, Johnston, RI, USA.
  2. AIK. (1998), Composite Deck Slab Standard (Proposal) and Commentary, Architectural Institution of Korea, Seoul, Korea. (in Korean).
  3. Kang, M. J., and Kim, S. S. (2015), Structural Performance Evaluation of Steel Wire-Integrated Deck Plate according to the Construction Load, Journal of Architectural Institute of Korea, AIK, 31(5), 3-12. (in Korean). https://doi.org/10.5659/JAIK_SC.2015.31.5.3
  4. Kim, S. B., Kang, M. J., Hwangbo, C., and Kim, S. S. (2014), Performance Evaluation for Steel Wire-Integrated Deck Plate according to the Location of Lattice End, Journal of Korean Society of Hazard Mitigation, 14(5), 9-17. (in Korean). https://doi.org/10.9798/KOSHAM.2014.14.5.9
  5. Lee, Y. J. (2010), Test Research of Structural Safety for Steel Wire-Integrated Deck Plate System, Journal of the Korea Institute of Structural Maintenance Inspection, KSMI, 14(6), 220-228. (in Korean).
  6. Lee, Y. J., and Yoon, S. C. (2012), Development of Steel Wire-Integrated Deck Plate Applicable to Slab with 180mm Thickness, Journal of the Korea Institute of Structural Maintenance Inspection, KSMI, 18(1), 89-98. (in Korean). https://doi.org/10.11112/jksmi.2012.16.1.089
  7. SDI. (2017), ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs, Steel Deck Institute, PA, USA.
  8. Xu, J. Wang, Z, Wang, P., Pan, J., and Li, B. (2021), Numerical Investigations on Large Size Stiffened Angle Connections with Different Bolt Patterns, Journal of Construction Steel Research, 182, 106670.
  9. Yang, K. H., Hong, J. K., Kim, S. H., and Lee, H. J. (2022), Structural Performance Evaluation and Design Guideline for End Supports of EXTR A Deck Plate System, Final R eport, Korea Institute for Structural Maintenance and Inspection, Seoul, Korea. (in Korean).