DOI QR코드

DOI QR Code

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination

일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석

  • Dong-Kyung Jung (Department of Radiologic Technology, Daegu Health College) ;
  • Myeong-Hwan Park (Department of Radiologic Technology, Daegu Health College) ;
  • Jeong-Min Seo (Department of Radiological Science, Catholic University of Pusan)
  • 정동경 (대구보건대학교 방사선학과) ;
  • 박명환 (대구보건대학교 방사선학과) ;
  • 서정민 (부산가톨릭대학교 방사선학과)
  • Received : 2023.12.10
  • Accepted : 2024.01.28
  • Published : 2024.02.28

Abstract

Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

Keywords

References

  1. Lim CS. A study on enacting the radiologic technologist act for the civil right to health in Korea. Journal of Radiological Science and Technology. 2007;30(4):313-20. Retrieved from https://m.riss.kr/search/detail/DetailView.do?p_mat_type=1a0202e37d52c72d&control_no=71e92c98cdb399f4ffe0bdc3ef48d419
  2. Jeong KH, Park CH. Comparative study of sterilization by gamma-ray and electron-beam. Journal of the Korean Society of Radiology. 2020;14(5):537-43. DOI: http://dx.doi.org/10.7742/jksr.2020.14.5.537
  3. The Ministry of Health & Welfare Ministry. Medical service act. Korea Ministry of Government Legislation; 2023.
  4. The Ministry of Health & Welfare Ministry. Enforcement decree of the medical service technologists, ETC. ACT, Korea Ministry of Government Legislation; 2018.
  5. Lee SY, Han DK. A study on the reduction of patient's exposure dose according to the arrival time of contrast media in abdominal CT scan using bolus tracking technique. Journal of the Korean Society of Radiology. 2021;15(2):93-100. DOI: http://dx.doi.org/10.7742/jksr.2021.15.2.93
  6. McVey G. The effect of phantom type, beam quality, field size and field position on X-ray scattering simulated using Monte Carlo techniques. British Journal of Radiology. 2006:79(938):130-71. DOI: http://dx.doi.org/10.1259/bjr/59998010
  7. Nuclear Safety and Security Commission. Enforcement decree of the nuclear safety act. Korea Ministry of Government Legislation; 2022.
  8. Lim CS. A study on the management of exposure of workers and assistants related to diagnostic radiation. Journal of the Korean Society of Law and Medicine. 2021;22(3):97-124. DOI: http://dx.doi.org/10.29291/kslm.2021.22.3.097
  9. Kim JE, Lee SH. Derivation of the effective energy calculation formula of the x-ray beam generated by the CT simulator. Journal of the Korean Society of Radiology. 2021;15(6):869-75. DOI: http://dx.doi.org/10.7742/jksr.2021.15.6.869
  10. Yoon CH, Yoon SH, Choi JG. Radiation exposure according to radiation technologist' working departments. Journal of Radiological Science and Technology. 2008;31(3):217-22. Retrieved from https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001278722
  11. Jeong KH, Jung DK, Seo JM. A study on the measurement linearity of hotoluminescent dosimeter. Journal of the Korean Society of Radiology. 2021;15(6):841-7. DOI: http://dx.doi.org/10.7742/jksr.2021.15.6.841
  12. Yeo JD, Ko IH, Kim HS. A study on perceptions by college students of radiology about the knowledge, attitudes and behaviors of radiation exposure management. Journal of the Korean Society of Radiology. 2015;9(1):79-99. DOI: http://dx.doi.org/10.7742/jksr.2015.9.2.79
  13. Park SJ, Lee HJ, Kang BS. A study on the public recognition change on radiation by providing education and practice. Journal of the Korean Society of Radiology. 2008;2(4):27-32. Retrieved from http://www.radlab.org/page/page_view?menu_num=119
  14. Jo YI, Kim JH, Bae SI. Evaluation of spatial dose rate in working environment during non-destructive testing using radioactive isotopes. Journal of the Korean Society of Radiology. 2022;16(4):373-9. DOI: http://dx.doi.org/10.7742/jksr.2022.16.4.373
  15. Kim CG. Spatial dose distribution and exposure dose during lumbar lateral test. Journal of the Korean Society of Radiology. 2014;5(1):17-22. DOI: http://dx.doi.org/10.15207/JKCS.2014.5.1.017
  16. Choi SK. Relationship between the distribution of space doses in x-ray rooms and the "inverse square law of distance". Journal of the Korea Contents Association. 2013;13(8):301-7. DOI: http://dx.doi.org/10.5392/JKCA.2013.13.08.301
  17. Kim JH, Shin EH. Spatial dose distribution for c-arm examination within operation room using monte carlo method. Journal of Radiological Science and Technology. 2021;44(3):205-10. DOI: http://dx.doi.org/10.17946/JRST.2021.44.3.205