DOI QR코드

DOI QR Code

Histological response of the periodontal tissue to mandibular incisor movement using clear aligners of varying thickness in a rabbit model

  • Yue Wang (Dental Medical Center, China-Japan Friendship Hospital) ;
  • He Liu (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Yueming Li (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Liwen Zhang (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Xun Yan (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Ruoxi Liu (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Xiao Shen (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Baohua Xu (Dental Medical Center, China-Japan Friendship Hospital) ;
  • Qiang Sun (Dental Medical Center, China-Japan Friendship Hospital)
  • Received : 2025.04.17
  • Accepted : 2025.07.21
  • Published : 2025.09.25

Abstract

Objective: Investigate the histological response of the periodontal tissue to incisor movement using varying-thickness clear aligners in a rabbit model. Methods: Thirty-three New Zealand rabbits were randomly assigned to two experimental groups (0.38-mm and 0.68-mm aligners) and a control group. Each rabbit in the experimental group wore three sequential aligners, which were changed every 5 days. Orthodontic force was measured using a uniaxial force sensor, and tooth movement was quantified using three-dimensional imaging. Root resorption was assessed using micro-computed tomography. Histological and immunohistochemical staining and real-time quantitative reverse transcription polymerase chain reaction tests were performed to evaluate the periodontal tissue response. Results: The 0.68-mm aligners generated larger forces than the 0.38-mm aligners. Tooth movement was faster with the third 0.38-mm aligner, with no statistically significant differences between the two groups. Both groups exhibited minor root resorption, with the 0.68-mm group exhibiting larger resorption craters. Additionally, the 0.68-mm group demonstrated more significant deformation of periodontal fibers and increased expression of inflammatory markers. The 0.38-mm group showed a larger number of osteoclasts on the compression side. Conclusions: Both aligners achieved effective tooth movement. The 0.38-mm aligners exerted smaller forces and enabled slightly faster movements than the 0.68-mm aligners. Although both groups showed minimal root resorption, the 0.68-mm group exhibited larger resorption craters. Furthermore, the 0.38-mm group exhibited less histological deformation and inflammation in the periodontal tissues. These results suggest that aligner thickness can be tailored to customize treatments. Further studies with longer observation periods and more refined methodologies are warranted.

Keywords

Acknowledgement

This work was supported by the Youth Fund of the China-Japan Friendship Hospital (2020-1-QN-1) and China-Japan Friendship Hospital High-level Clinical Special Fund (2023-NHLHCRF-YXHZ-MS-10).

References

  1. Pithon MM, Baião FCS, Sant Anna L, Paranhos LR, Cople Maia L. Assessment of the effectiveness of invisible aligners compared with conventional appliance in aesthetic and functional orthodontic treatment: a systematic review. J Investig Clin Dent 2019;10:e12455. https://doi.org/10.1111/jicd.12455
  2. Uzunçıbuk H, Russo D, Marrapodi MM, Cicciù M, Minervini G. Comparing clear aligner treatments with multi-bracket systems: advantages and disadvantages. J Contemp Orthod 2025;9:3-6. https://doi.org/10.18231/j.jco.2025.002
  3. Hahn W, Dathe H, Fialka-Fricke J, Fricke-Zech S, Zapf A, Kubein-Meesenburg D, et al. Influence of thermoplastic appliance thickness on the magnitude of force delivered to a maxillary central incisor during tipping. Am J Orthod Dentofacial Orthop 2009;136:12.e1-7; discussion 12-3. https://doi.org/10.1016/j.ajodo.2008.12.015
  4. Kohda N, Iijima M, Muguruma T, Brantley WA, Ahluwalia KS, Mizoguchi I. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances. Angle Orthod 2013;83:476-83. https://doi.org/10.2319/052512-432.1
  5. Wang Y, Jia L, Zheng Y, Li W. Bone remodeling induced by mechanical forces is regulated by miRNAs. Biosci Rep 2018;38:BSR20180448. https://doi.org/10.1042/bsr20180448
  6. Jeon HH, Teixeira H, Tsai A. Mechanistic insight into orthodontic tooth movement based on animal studies: a critical review. J Clin Med 2021;10:1733. https://doi.org/10.3390/jcm10081733
  7. Ibrahim AY, Gudhimella S, Pandruvada SN, Huja SS. Resolving differences between animal models for expedited orthodontic tooth movement. Orthod Craniofac Res 2017;20 Suppl 1:72-6. https://doi.org/10.1111/ocr.12175
  8. Li GH, Pan XG. [Experimental study on the effect of tooth movement with thin and thick aligners in rabbits]. Shanghai Kou Qiang Yi Xue 2021;30:38-43. Chinese. https://pubmed.ncbi.nlm.nih.gov/33907777/
  9. Suzuki SS, Garcez AS, Reese PO, Suzuki H, Ribeiro MS, Moon W. Effects of corticopuncture (CP) and low-level laser therapy (LLLT) on the rate of tooth movement and root resorption in rats using micro-CT evaluation. Lasers Med Sci 2018;33:811-21. https://doi.org/10.1007/s10103-017-2421-5
  10. Oshiro T, Shiotani A, Shibasaki Y, Sasaki T. Osteoclast induction in periodontal tissue during experimental movement of incisors in osteoprotegerin-deficient mice. Anat Rec 2002;266:218-25. https://doi.org/10.1002/ar.10061
  11. van den Bos T, Tonino GJ. Composition and metabolism of the extracellular matrix in the periodontal ligament of impeded and unimpeded rat incisors. Arch Oral Biol 1984;29:893-7. https://doi.org/10.1016/0003-9969(84)90088-8
  12. Morris PJR, Cox PG, Cobb SNF. The biomechanical significance of the elongated rodent incisor root in the mandible during incision. Sci Rep 2022;12:3819. https://doi.org/10.1038/s41598-022-07779-z
  13. Sombuntham NP, Songwattana S, Atthakorn P, Jungudomjaroen S, Panyarachun B. Early tooth movement with a clear plastic appliance in rats. Am J Orthod Dentofacial Orthop 2009;136:75-82. https://doi.org/10.1016/j.ajodo.2007.08.021
  14. Ren Y, Maltha JC, Kuijpers-Jagtman AM. Optimum force magnitude for orthodontic tooth movement: a systematic literature review. Angle Orthod 2003;73:86-92. https://doi.org/10.1043/0003-3219(2003)073<0086:Ofmfot>2.0.Co;2
  15. Storey E. The nature of tooth movement. Am J Orthod 1973;63:292-314. https://doi.org/10.1016/0002-9416(73)90353-9
  16. Castroflorio T, Gamerro EF, Caviglia GP, Deregibus A. Biochemical markers of bone metabolism during early orthodontic tooth movement with aligners. Angle Orthod 2017;87:74-81. https://doi.org/10.2319/022416-159.1
  17. Wang Y, Zheng Y, Li W. Compression loading of osteoclasts attenuated microRNA-146a-5p expression, which promotes angiogenesis by targeting adiponectin. Sci China Life Sci 2022;65:151-66. https://doi.org/10.1007/s11427-020-1869-7
  18. Wang Y, Zheng Y, Li W. Exosomes derived from osteoclasts under compression stress inhibit osteoblast differentiation. Biocell 2021;45:427-44. https://doi.org/10.32604/biocell.2021.013960
  19. Fang Z, Cheng G, He M, Lin Y. CYP27A1 deficiency promoted osteoclast differentiation. PeerJ 2023;11:e15041. https://doi.org/10.7717/peerj.15041
  20. Zhang R, Sougawa N, Mao D, Inoue H, Goda S. Signaling pathways of pro-IL-1β production induced by mechanical stress in gingival epithelial cells. J Oral Biosci 2025;67:100626. https://doi.org/10.1016/j.job.2025.100626
  21. Tartaglia GM, Mapelli A, Maspero C, Santaniello T, Serafin M, Farronato M, et al. Direct 3D printing of clear orthodontic aligners: current state and future possibilities. Materials (Basel) 2021;14:1799. https://doi.org/10.3390/ma14071799
  22. Jindal P, Juneja M, Siena FL, Bajaj D, Breedon P. Mechanical and geometric properties of thermoformed and 3D printed clear dental aligners. Am J Orthod Dentofacial Orthop 2019;156:694-701. https://doi.org/10.1016/j.ajodo.2019.05.012
  23. Edelmann A, English JD, Chen SJ, Kasper FK. Analysis of the thickness of 3-dimensional-printed orthodontic aligners. Am J Orthod Dentofacial Orthop 2020;158:e91-8. https://doi.org/10.1016/j.ajodo.2020.07.029