DOI QR코드

DOI QR Code

Accuracy assessment of Smart stereolithography models generated by Dental Monitoring®: A pilot study

  • Stratos Vassis (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Dimitra Karamalaki (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Jason Liu (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Beatrice Noeldeke (Institute for Environmental Economics and World Trade, Leibniz University of Hanover) ;
  • Mohammedreza Sefidroodi (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Sukeshana Srivastav (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Julian Woolley (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University) ;
  • Peter Stoustrup (Department of Dentistry and Oral Health, Section of Orthodontics, Aarhus University)
  • Received : 2025.02.03
  • Accepted : 2025.04.28
  • Published : 2025.09.25

Abstract

Objective: This pilot study aims to evaluate the clinical accuracy of Smart stereolithography (STL) files generated by the Dental Monitoring® (DM) system by comparing them with gold standard intraoral scans (IOSs). Methods: Seven aligner patients using the DM application were included. For each patient, Smart STL files generated from remote scans were superimposed onto IOSs using the best-fit algorithm in OnyxCeph software. Differences regarding inclination, angulation, rotation, buccal/lingual, mesial/distal, and intrusion/extrusion were quantified and statistically compared. Results: Statistically significant differences were observed in inclination, mesial/distal, and buccal/lingual movements, particularly in the posterior segments. However, all deviations remained within clinically acceptable thresholds for single aligner tooth movement. Conclusions: Despite minor deviations, Smart STL files generated by DM demonstrated sufficient accuracy for use in aligner planning and refinement. These findings highlight the potential of DM-generated Smart STL files for subsequent aligner treatment.

Keywords

References

  1. Lo Giudice A, Ronsivalle V, Venezia P, Ragusa R, Palazzo G, Leonardi R, et al. Teleorthodontics: where are we going? From skepticism to the clinical applications of a new medical communication and management system. Int J Dent 2022;2022:7301576. https://doi.org/10.1155/2022/7301576
  2. Caruso S, Caruso S, Pellegrino M, Skafi R, Nota A, Tecco S. A knowledge-based algorithm for automatic monitoring of orthodontic treatment: the dental monitoring system. Two cases. Sensors (Basel) 2021;21:1856. https://doi.org/10.3390/s21051856
  3. Morris RS, Hoye LN, Elnagar MH, Atsawasuwan P, Galang-Boquiren MT, Caplin J, et al. Accuracy of Dental Monitoring 3D digital dental models using photograph and video mode. Am J Orthod Dentofacial Orthop 2019;156:420-8. https://doi.org/10.1016/j.ajodo.2019.02.014
  4. Homsi K, Snider V, Kusnoto B, Atsawasuwan P, Viana G, Allareddy V, et al. In-vivo evaluation of Artificial Intelligence Driven Remote Monitoring technology for tracking tooth movement and reconstruction of 3-dimensional digital models during orthodontic treatment. Am J Orthod Dentofacial Orthop 2023;164:690-9. https://doi.org/10.1016/j.ajodo.2023.04.019
  5. Sangalli L, Alessandri-Bonetti A, Dalessandri D. Effectiveness of dental monitoring system in orthodontics: a systematic review. J Orthod 2024;51:28-40. https://doi.org/10.1177/14653125231178040
  6. Pomerleau F, Colas F, Siegwart R, Magnenat S. Comparing ICP variants on real-world data sets. Auton Robots 2013;34:133-48. https://doi.org/10.1007/s10514-013-9327-2
  7. Adel SM, Vaid NR, El-Harouni N, Kassem H, Zaher AR. Digital model superimpositions: are different software algorithms equally accurate in quantifying linear tooth movements? BMC Oral Health 2022;22:103. https://doi.org/10.1186/s12903-022-02129-x
  8. Boyd RL, Miller RJ, Vlaskalic V. The invisalign system in adult orthodontics: mild crowding and space closure cases. J Clin Orthod 2000;34:203-12. https://www.jco-online.com/archive/2000/04/203-the-invisalign-system-in-adult-orthodontics-mild-crowding-and-space-closure-cases/
  9. Kravitz ND, Kusnoto B, BeGole E, Obrez A, Agran B. How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with Invisalign. Am J Orthod Dentofacial Orthop 2009;135:27-35. https://doi.org/10.1016/j.ajodo.2007.05.018
  10. Koenig N, Choi JY, McCray J, Hayes A, Schneider P, Kim KB. Comparison of dimensional accuracy between direct-printed and thermoformed aligners. Korean J Orthod 2022;52:249-57. https://doi.org/10.4041/kjod21.269
  11. Xiao Q, Zhou K, Wang L, Gao J, Chen J, Ren Y. Accuracy of iTero Element 1 intraoral scanner digital model in mild to moderate crowding of the maxillary and mandibular arch. J Kunming Med Univ 2023;44:149-54. https://doi.org/10.12259/j.issn.2095-610X.S20231025
  12. Pellitteri F, Albertini P, Vogrig A, Spedicato GA, Siciliani G, Lombardo L. Comparative analysis of intraoral scanners accuracy using 3D software: an in vivo study. Prog Orthod 2022;23:21. https://doi.org/10.1186/s40510-022-00416-5