DOI QR코드

DOI QR Code

Analysis of muscle morphology and knee joint range of motion of rat preserved using a modified Larssen solution

  • Martin (Biomedical Sciences, Faculty of Medicine, Universitas Indonesia) ;
  • Ria Margiana (Biomedical Sciences, Faculty of Medicine, Universitas Indonesia) ;
  • Deswaty Furqonita (Biomedical Sciences, Faculty of Medicine, Universitas Indonesia)
  • 투고 : 2025.07.15
  • 심사 : 2025.12.04
  • 발행 : 2026.03.31

초록

Cadavers are essential for anatomical education, but limited availability necessitates long-term preservation. While formalin is widely used, it is carcinogenic and alters muscle morphology and joint mobility, reducing anatomical accuracy. The modified Larssen solution (MLS) has shown promise in improving joint flexibility, yet its efficacy remains underexplored. This study aimed to evaluate muscle condition and joint range of motion in rat specimens preserved with 4% formalin followed by MLS immersion, compared to continuous 4% formalin preservation. Eighteen rat cadavers were allocated into three groups: intracardiac perfusion followed by 0.9% NaCl immersion, intracardiac perfusion and threemonth immersion in 4% formalin, and intracardiac perfusion with 4% formalin followed by three-month immersion in MLS. Statistical analysis included the t-test or Mann-Whitney test, depending on data distribution. Pearson correlation was used to assess the relationship between muscle fiber fragmentation and joint range of motion. Data from the NaCl group were excluded due to sample decomposition. The MLS group showed significantly redder muscle color (P<0.05), softer muscle consistency (P<0.05), and a non-significant increase in joint range of motion (P>0.05), without observable muscle fiber fragmentation. Correlation analysis could not be conducted due to the absence of fragmentation. MLS may serve as an effective alternative preservative by maintaining muscle color, texture, and structural integrity. Although the increase in joint mobility was not statistically significant, it was more pronounced than in the 4% formalin group. Future studies should explore longer observation periods and potential correlations with histological findings.

키워드

과제정보

We would like to express gratitude to Anatomy Department of Universitas Indonesia for supporting this review.

참고문헌

  1. Kaliappan A, Motwani R, Gupta T, Chandrupatla M. Innovative cadaver preservation techniques: a systematic review. Maedica (Bucur) 2023;18:127-35.
  2. Hauptmann M, Lubin JH, Stewart PA, Hayes RB, Blair A. Mortality from solid cancers among workers in formaldehyde industries. Am J Epidemiol 2004;159:1117-30. https://doi.org/10.1093/aje/kwh174
  3. Whitehead MC, Savoia MC. Evaluation of methods to reduce formaldehyde levels of cadavers in the dissection laboratory. Clin Anat 2008;21:75-81. https://doi.org/10.1002/ca.v21:1
  4. Protano C, Buomprisco G, Cammalleri V, Pocino RN, Marotta D, Simonazzi S, Cardoni F, Petyx M, Iavicoli S, Vitali M. The carcinogenic effects of formaldehyde occupational exposure: a systematic review. Cancers (Basel) 2021;14:165. https://doi.org/10.3390/cancers14010165
  5. Bilge O, Celik S. Cadaver embalming fluid for surgical training courses: modified Larssen solution. Surg Radiol Anat 2017;39: 1263-72. https://doi.org/10.1007/s00276-017-1865-4
  6. Ottone NE, Vargas CA, Fuentes R, Del Sol M. Walter Thiel's embalming method. Review of solutions and applications in different fields of biomedical research. Int J Morphol 2016;34: 1442-54. https://doi.org/10.4067/S0717-95022016000400044
  7. Benet A, Rincon-Torroella J, Lawton MT, González Sánchez JJ. Novel embalming solution for neurosurgical simulation in cadavers. J Neurosurg 2014;120:1229-37. https://doi.org/10.3171/2014.1.JNS131857
  8. Martin, Margiana R. A comprehensive review of the chemical composition and toxicological impact of Larsen embalming fluid in medical anatomy laboratories: implications for neonatal rat surgery preparation. J Neonatal Surg 2025;14:160-9. https://doi.org/10.52783/jns.v14.2016
  9. Lakes EH, Allen KD. Gait analysis methods for rodent models of arthritic disorders: reviews and recommendations. Osteoarthritis Cartilage 2016;24:1837-49. https://doi.org/10.1016/j.joca.2016.03.008
  10. Vanek T, Kohli A. Biochemistry, myoglobin. In: StatPearls. StatPearls Publishing; 2023.
  11. Alala B, Mwangi W, Okeyo G. Image representation using RGB color space. Int J Innov Res Dev 2014;3:322-8.
  12. Smith DG, Schenk MP. Dissection guide & atlas to the rat. Morton Publishing Company; 2001.
  13. Benkhadra M, Bouchot A, Gérard J, Genelot D, Trouilloud P, Martin L, Girard C, Danino A, Anderhuber F, Feigl G. Flexibility of Thiel's embalmed cadavers: the explanation is probably in the muscles. Surg Radiol Anat 2011;33:365-8. https://doi.org/10.1007/s00276-010-0703-8
  14. Brooks JW. Postmortem changes in animal carcasses and estimation of the postmortem interval. Vet Pathol 2016;53:929-40. https://doi.org/10.1177/0300985816629720
  15. Arifin WN, Zahiruddin WM. Sample size calculation in animal studies using resource equation approach. Malays J Med Sci 2017;24:101-5. https://doi.org/10.21315/mjms
  16. Evelyn F, Margiana R. The comparison of decrease in mice mass preserved with formalin 4% and neutralize with sodium bicarbonate. Anat Cell Biol 2022;55:459-66. https://doi.org/10.5115/acb.21.232
  17. Wijaya AN, Margiana R, Kusumaningtyas S, Furqonita D. Comparison of decomposition rate of hind limbs of preserved mice with ethanol-glycerin and formaldehyde of advanced fixative solution. Anat Cell Biol 2021;54:225-31. https://doi.org/10.5115/acb.20.314
  18. Guimarães da Silva RM, Matera JM, Ribeiro AA. Preservation of cadavers for surgical technique training. Vet Surg 2004;33: 606-8. https://doi.org/10.1111/vsu.2004.33.issue-6
  19. Gage GJ, Kipke DR, Shain W. Whole animal perfusion fixation for rodents. J Vis Exp 2012;65:3564.
  20. Mrożek A, Sędzik M, Rubin J, Buras S, Tarkowski V, Domagała Z. Cadaver preserving methods – is it possible to do anything better? Med J Cell Biol 2022;10:124-8. https://doi.org/10.2478/acb-2022-0019
  21. Boduç E, Çelik E, Özdemir B. Evaluation of the fixation effect of modified Larssen, Klotz, formalin 10% and saturated sall solutions on heart tissue. Int J Med Sci Dent Res 2023;6:196-203.
  22. Dellalana LE, Chen F, Vain A, Gandelman JS, Põldemaa M, Chen H, Tkaczyk ER. Reproducibility of the durometer and myoton devices for skin stiffness measurement in healthy subjects. Skin Res Technol 2019;25:289-93. https://doi.org/10.1111/srt.2019.25.issue-3
  23. Dahlan MS. [Statistics for medicine and health]. 6th ed. Epidemiologi Indonesia; 2020. Indonesian.
  24. Piña-Oviedo S, Ortiz-Hidalgo C, Ayala AG. Human colors-the rainbow garden of pathology: what gives normal and pathologic tissues their color? Arch Pathol Lab Med 2017;141:445-62. https://doi.org/10.5858/arpa.2016-0274-SA
  25. Gee-Mascarello S. Embalming: history, theory, and practice. 6th ed. McGraw Hill Professional; 2022.
  26. Vankar PS, Dwivedi A, Saraswat R. Sodium sulphate as a curing agent to reduce saline chloride ions in the tannery effluent at Kanpur: a preliminary study on techno-economic feasibility. Desalination 2006;201:14-22. https://doi.org/10.1016/j.desal.2005.12.030
  27. Aaldijk D, Reusser A, Eppler E, Yao E, Djonov V, Halm S. Morphological changes in striated muscle fibres caused by components of the Thiel embalming method. Folia Morphol (Warsz) 2024;83:83-91.
  28. McDougall S, Soames R, Felts P. Thiel embalming: quantifying histological changes in skeletal muscle and tendon and investigating the role of boric acid. Clin Anat 2020;33:696-704. https://doi.org/10.1002/ca.v33.5
  29. Layton C, Bancroft JD, Suvarna SK. 4 - Fixation of tissues. In: Suvarna SK, Layton C, Bancroft JD, editors. Bancroft's theory and practice of histological techniques. 8th ed. Elsevier; 2019.
  30. Metz B, Kersten GF, Hoogerhout P, Brugghe HF, Timmermans HA, de Jong A, Meiring H, ten Hove J, Hennink WE, Crommelin DJ, Jiskoot W. Identification of formaldehyde-induced modifications in proteins: reactions with model peptides. J Biol Chem 2004;279:6235-43.
  31. Swatland HJ. Effect of pH on the birefringence of skeletal muscle fibers measured with a polarizing microscope. Trans Am Microsc Soc 1990;109:361-7. https://doi.org/10.2307/3226690