Abstract

An improved grouting-anchor connection method of precast concrete shear walls (PCSWs) is proposed. The connection was composed of filling grouting material in metal corrugated pipe, used to effective the overlap of steel bars between walls, as well as surrounded spiral stirrups complete valid constrain. This paper focuses on the influence of the lap length of the connecting steel bar on improved connection for precast concrete shear wall in order to explore the seismic performance based previous research results. Four precast concrete shear walls with improved grouting anchorage connection with lap length of 0.7la (25d) and 0.9la (32d) (la as the anchorage length of tensile steel bar, d as diameter of steel bar) and two precast concrete shear walls with traditional grouting anchorage (TGA) connection with lap length of 0.9la experiments under cyclic loading were carried out. Experimental findings indicated that a lap length of 0.7la offers seismic performance comparable to that of 0.9la, accompanied by only slight reductions in ductility, stiffness, and energy dissipation. Therefore, 0.7la is recommended for enhancing construction efficiency while maintaining an acceptable performance trade-off, whereas 0.9la is more suitable for conservative design. Further seismic behaviors analysis of different lap lengths, 0.7la (25d) to1.6la (56d), as well as traditional direct anchoring connections were studied by ABAQUS. Finally, a new shear calculation formula on the lap lengths of these improved connection has been proposed and verified as well.

Keywords

Acknowledgement

The authors acknowledge the financial support from the National Key Research Project on Theory of efficient reinforcement and performance-based design for precast concrete members under Grant Nos 2016YFC0701402, the Key Projects of Liaoning Provincial Department of Education under Grant Nos JYTZD2023163 and General Project of Liaoning Provincial Department of Education under Grant Nos JYTMS20231571

References

  1. Biondini, F., Dal Lago, B., Toniolo, G. (2013). Role of wall panel connections on the seismic performance of precast structures. Bulletin of Earthquake Engineering, 11, 1061-1081. https://doi.org/10.1007/s10518-012-9418-z.
  2. Dal Lago, B., Biondini, F., Toniolo, G. (2017). Friction-based dissipative devices for precast concrete panels. Engineering Structures, 147, 356-371. https://doi.org/10.1016/j.engstruct.2017.05.050.
  3. Dal Lago, B., Biondini, F., Toniolo, G. (2018). Experimental tests on multiple-slit devices for precast concrete panels. Engineering Structures, 167, 420-430. https://doi.org/10.1016/j.engstruct.2018.04.035.
  4. Ye, M., Jiang, J., Chen, H.M., Zhou, H.Y., Song, D.D. (2021). Seismic behavior of an innovative hybrid beam-column connection for precast concrete structures. Engineering Structures, 227, 111436. https://doi.org/10.1016/j.engstruct.2020.111436.
  5. Ling, J.H., Rahman, A.B.A., Ibrahim, I.S., Hamid, Z.A. (2016). Tensile capacity of grouted splice sleeves. Engineering Structures, 111, 285-296. https://doi.org/10.1016/j.engstruct.2015.12.023.
  6. Wang, W., Li, A., Wang, X. (2018). Seismic performance of precast concrete shear wall structure with improved assembly horizontal wall connections. Bulletin of Earthquake Engineering, 16, 4133-4158. https://doi.org/10.1007/s10518-018-0348-2.
  7. Wang, W., Li, A., Wang, X. (2018). Seismic performance of base-isolated precast concrete shear wall structure with AHW connections. Shock and Vibration, 2018, 1-22. https://doi.org/10.1155/2018/9632523.
  8. Li, W., Gao, H., Xiang, R., Du, Y. (2021). Experimental study of seismic performance of precast shear wall with a new bolt-plate connection joint. Structures. 34, 3818-3833. https://doi.org/10.1016/j.istruc.2021.10.009.
  9. Xue, W., Huang, Q., Niu, P. (2022). Reversed cyclic tests on precast concrete shear walls with grouted corrugated metallic duct connections. Engineering Structures, 256, 113948. https://doi.org/10.1016/j.engstruct.2022.113948.
  10. Xue, W., Huang, Q., Li, Y. (2022). Experimental study of precast concrete shear walls with spiralconfined lap connections under cyclic loads. Journal of Building Engineering, 52, 104467. https://doi.org/10.1016/j.jobe.2022.104467.
  11. Xue, W., Huang, Q., Yang, J., Li, Z. (2023). Cyclic response of precast concrete shear walls with reduced grouted sleeves or corrugated metallic duct splices. Case Studies in Construction Materials, 18, e01822. https://doi.org/10.1016/j.cscm.2023.e01822.
  12. Xue, W., Huang, Q., Gu, X., Hu, X. (2022, April). Hysteretic behavior of precast concrete shear walls with steel sleeve-corrugated metallic duct hybrid connections. Structures, 38, 820-831. https://doi.org/10.1016/j.istruc.2022.02.034.
  13. Sookree, E.W., Huang, Z., Wang, Z. (2023). A numerical study on the seismic performance of a horizontal dry connection for precast concrete shear walls. KSCE Journal of Civil Engineering, 27(4), 1617-1639. https://doi.org/10.1007/s12205-023-2309-9.
  14. Yooprasertchai, E., Wiwatrojanagul, P., Saingam, P., Khan, K. (2023). Cyclic behavior of different connections in precast concrete shear walls: Experimental and analytical investigations. Buildings, 13(6), 1433. https://doi.org/10.3390/buildings13061433.
  15. Liu, Y.L., Kumar, S., Wang, D.H., Guo, D. (2024). Effect of vertical reinforcement connection level on seismic behavior of precast RC shear walls: Experimental study. Earthquakes and Structures, 26(6), 449-461. https://doi.org/10.12989/eas.2024.26.6.449.
  16. Chen, X., Liu, M., Biondini, F., Rosati, G. (2019). Structural behavior of precast reinforced concrete shear walls with large-diameter bars. ACI Structural Journal, 116(5), 77-86. https://doi.org/10.14359/51715657.
  17. JGJ/T 101(2015). Specification for seismic test of buildings. Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China.
  18. Lee, J., Fenves, G.L. (1998). Plastic-damage model for cyclic loading of concrete structures. Journal of Engineering Mechanics, 124(8), 892-900. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:8(892).
  19. ACI 318 (2019). Building code requirements for structural concrete and commentary. American Concrete Institute, Farmington Hills, MI, USA.
  20. EN 1992-1-1 (2004). Eurocode 2: Design of concrete structures — Part 1-1: General rules and rules for buildings. European Committee for Standardization, Brussels, Belgium.
  21. AS 3600 (2018). Concrete structures. Standards Australia, Sydney, Australia.
  22. JGJ 3 (2010). Technical specification for concrete structures of tall building. Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China.