DOI QR코드

DOI QR Code

Proposal for an automatic damping and reverse system (AD&RS) for reinforced concrete buildings

  • Recep Suk (Genser Engineering Architecture Construction Industry and Trade Co. Ltd., DEPARK Technology Development Zone, Dokuz Eylul University Tınaztepe Campus) ;
  • Mert Genc (Genser Engineering Architecture Construction Industry and Trade Co. Ltd., DEPARK Technology Development Zone, Dokuz Eylul University Tınaztepe Campus) ;
  • Ozgur Girgin (Genser Engineering Architecture Construction Industry and Trade Co. Ltd., DEPARK Technology Development Zone, Dokuz Eylul University Tınaztepe Campus)
  • Received : 2026.05.14
  • Accepted : 2026.06.17
  • Published : 2026.08.25

Abstract

Friction-type dampers exhibit a nearly constant friction-force response throughout the displacement history under loading conditions. Although this behavior improves the overall energy dissipation capacity of structures subjected to seismic excitation by providing additional damping, supplementary mechanisms are generally required to mitigate the adverse effects of residual displacements. In this study, an Automatic Damping and Reverse System (AD&RS) device capable of significantly reducing residual displacements was developed and experimentally investigated. In addition, the force-displacement behavior of the AD&RS device was compared with that of a reference device without a spring mechanism, and the fundamental differences between the two systems were comprehensively evaluated. Furthermore, the seismic performance of reinforced concrete (RC) frames with and without the AD&RS device (conventional system) was investigated in accordance with the Turkish Building Earthquake Code (TBEC-2018). The experimental results demonstrated that, at a displacement level of 15 mm and under a torque value of 50 Nm, the reference device generated a reaction force of 8.93 kN, whereas the AD&RS device produced a significantly higher reaction force of 58.32 kN, corresponding to an increase of 553.08%. Similarly, under a torque value of 100 Nm, the increase ratio was determined to be 546.62%. Moreover, nonlinear structural performance analyses performed in accordance with TBEC-2018 revealed that 12.5% of the columns and 50% of the beams in the conventional RC frame failed to satisfy the prescribed performance criteria. In contrast, when the AD&RS device was integrated into the structural system, all columns and beams remained within the allowable performance limits. Overall, the findings clearly demonstrate that the AD&RS device substantially enhances the reaction-force capacity compared with the reference device. Furthermore, the proposed system can be considered an effective and promising solution for improving the seismic performance of reinforced concrete frame systems.

Keywords

Acknowledgement

The damper device used in this study was funded under the TUBITAK 1832 "Green Transformation in Industry" Call (Project No: 3258055). The authors would like to gratefully acknowledge TUBITAK for its financial support. The authors also sincerely thank the Earthquake Engineering Laboratory of the Faculty of Civil Engineering at Ege University for providing experimental facilities. In addition, the support and collaboration of Genser Engineering Architecture Construction Industry and Trade Ltd. Co. are greatly appreciated.

References

  1. Esfahani, M.R., Kianoush, M.R., Tajari, A.R. (2007). Flexural behaviour of reinforced concrete beams strengthened by CFRP sheets. Engineering Structures, 29(10), 2428-2444. https://doi.org/10.1016/j.engstruct.2006.12.008.
  2. Garcia, R., Hajirasouliha, I., Pilakoutas, K. (2010). Seismic behaviour of deficient RC frames strengthened with CFRP composites. Engineering Structures, 32(10), 3075-3085. https://doi.org/10.1016/j.engstruct.2010.05.026.
  3. Wang, D.Y., Wang, Z.Y., Yu, T., Li, H. (2017). Shake table tests of large-scale substandard RC frames retrofitted with CFRP wraps before earthquakes. Journal of Composites for Construction, 21(1), 04016062. https://doi.org/10.1061/(ASCE)CC.1943-5614.0000720.
  4. Zhang, Y., Cheng, X., Diao, M., Li, Y., Guan, H., Sun, H. (2023). FRP retrofit for RC frame substructures against progressive collapse: Scheme optimisation and resistance calculation. Engineering Structures, 289, 116289. https://doi.org/10.1016/j.engstruct.2023.116289.
  5. Zhu, J.T., Wang, X.L., Xu, Z.D., Weng, C.H. (2011). Experimental study on seismic behavior of RC frames strengthened with CFRP sheets. Composite Structures, 93(6), 1595-1603. https://doi.org/10.1016/j.compstruct.2011.01.007.
  6. Aldhafairi, F., Hassan, A., Abd-EL-Hafez, L.M., Abouelezz, A.E.Y. (2020). Different techniques of steel jacketing for retrofitting of different types of concrete beams after elevated temperature exposure. Structures, 28, 713-725. https://doi.org/10.1016/j.istruc.2020.09.017.
  7. Sudha, C., Sambasivan, A.K., PR, K.R., Jegan, M. (2022). Investigation on the performance of reinforced concrete columns jacketed by conventional concrete and geopolymer concrete. Engineering Science and Technology, an International Journal, 36, 101275. https://doi.org/10.1016/j.jestch.2022.101275.
  8. Ioannou, A.I., Pantazopoulou, S.J., Petrou, M.F., Charmpis, D.C. (2025). Seismic retrofit of predamaged RC elements using thin strain-hardening cementitious composite jackets. Bulletin of Earthquake Engineering, 23(5), 2171-2200. https://doi.org/10.1007/s10518-024-02090-w.
  9. Villar-Salinas, S., Guzmán, A., Carrillo, J. (2021). Performance evaluation of structures with reinforced concrete columns retrofitted with steel jacketing. Journal of Building Engineering, 33, 101510. https://doi.org/10.1016/j.jobe.2020.101510.
  10. Camarda, G., Sorrentino, P., De Luca, A. (2023). Hybrid strategy for the seismic retrofitting of existing buildings through base isolation System. Procedia Structural Integrity, 44, 1292-1299. https://doi.org/10.1016/j.prostr.2023.01.166.
  11. Islam, A. S., Jumaat, M. Z., Ahmmad, R., ud Darain, K.M. (2015). Retrofitting of vulnerable RC structures by base isolation technique. Earthquakes and Structures, 9(3), 603-623. https://doi.org/10.12989/eas.2015.9.3.603.
  12. Mazza, F., Mazza, M., Vulcano, A. (2018). Base-isolation systems for the seismic retrofitting of R.C. framed buildings with soft-storey subjected to near-fault earthquakes. Soil Dynamics and Earthquake Engineering, 109, 209-221. https://doi.org/10.1016/j.soildyn.2018.02.025.
  13. Gao, J., Song, S., Wang, C.L., Zeng, B. (2024). Development and optimization of a novel response-amplified friction damper with different friction pairs. Earthquake Engineering & Structural Dynamics, 53(3), 1285-1307. https://doi.org/10.1002/eqe.4070.
  14. Gao, J., Yuan, Y., Qiu, T., Wang, C.L., Qu, Z. (2022). Performance optimization and loading rate-dependency of friction dampers with non-metallic friction materials. Journal of Building Engineering, 54, 104609. https://doi.org/10.1016/j.jobe.2022.104609.
  15. Jarrahi, H., Asadi, A., Khatibinia, M., Etedali, S. (2020). Optimal design of rotational friction dampers for improving seismic performance of inelastic structures. Journal of Building Engineering, 27, 100960. https://doi.org/10.1016/j.jobe.2019.100960.
  16. Moghaddam, H., Afzalinia, F., Hajirasouliha, I. (2022). Optimal distribution of friction dampers to improve the seismic performance of steel moment resisting frames. Structures, 37, 624-644. https://doi.org/10.1016/j.istruc.2022.01.007.
  17. Westenenk, B., Edwards, J.J., de la Llera, J.C., Jünemann, R. (2019). Self-centering frictional damper (SCFD). Engineering Structures, 197, 109425. https://doi.org/10.1016/j.engstruct.2019.109425.
  18. Li, Y., Zhang, H., Wang, J., Yu, H., Ma, K., Zhang, X., Ji, W., Li, R. (2023). Experimental investigation on the seismic behavior of a novel self-centering friction damper. Journal of Building Engineering, 76, 107384. https://doi.org/10.1016/j.jobe.2023.107384.
  19. Shi, F., Yuan, W., Cao, S., Ozbulut, O.E. (2024). Comparative seismic performance evaluation of friction, self-centering and hybrid self-centering dampers. Journal of Constructional Steel Research, 218, 108700. https://doi.org/10.1016/j.jcsr.2024.108700.
  20. Wang, J., Han, J., Xu, J. (2025). Development of an innovative ring spring-based self-centering friction damper. Journal of Constructional Steel Research, 227, 109363. https://doi.org/10.1016/j.jcsr.2025.109363.
  21. Li, R., Chen, Q., He, Y., Chen, S., Ge, H. (2025). Experimental and numerical simulation analyses of a displacement-dependent self-centering variable friction damper. Soil Dynamics and Earthquake Engineering, 194, 109384. https://doi.org/10.1016/j.soildyn.2025.109384.
  22. Shi, J., Zhang, W., Zhang, C., Zheng, Y. (2024). Development and validation of a hysteretic model for a novel self-centering friction damper. Structures, 64, 106620. https://doi.org/10.1016/j.istruc.2024.106620.
  23. Zhang, Z., Shen, H., Wang, Q. (2023). Mechanical characteristics of a novel variable friction hybrid self-centering damper. Structures, 58, 105424. https://doi.org/10.1016/j.istruc.2023.105424.
  24. Yang, Y., Xue, J., Luo, Z., Liu, R. (2024). Manufacturing, testing and simulation of novel dual-stage energy-dissipation and self-centering friction damper. Journal of Constructional Steel Research, 222, 108949. https://doi.org/10.1016/j.jcsr.2024.108949.
  25. Yang, Y., Xue, J., Luo, Z., Liu, R. (2025). Experimental and numerical investigation on a novel dual-stage friction self-centering damper. Engineering Structures, 326, 119606. https://doi.org/10.1016/j.engstruct.2024.119606.
  26. Qiu, C., Huangfu, H., Liu, J., Cao, Y., Du, X., Liu, H. (2025). Experimental, analytical, and numerical study of a wall-type self-centering slip friction damper. Engineering Structures, 323, 119296. https://doi.org/10.1016/j.engstruct.2024.119296.
  27. Chopra, A.K. (2012). Dynamics structures: Theory and applications to earthquake engineering (4th edition). Prentice Hall, Hoboken, NJ, USA.
  28. Saraç, İ. (2022). The numerical investigation of the effects of hole tolerance and bolt torque variation on the joint strength in the bolted joints. Journal of the Faculty of Engineering and Architecture of Gazi University, 37(2), 685-695. https://doi.org/10.17341/gazimmfd.761996.
  29. Lee, J., Kim, D., Seok, C.S. (2022). Methodology for evaluating the tightening torque-clamping force relationship and friction coefficients in bolted joints. Journal of Mechanical Science and Technology, 36(4), 1913-1919. https://doi.org/10.1007/s12206-022-0328-y.
  30. Chakherlou, T.N., Razavi, M.J., Aghdam, A.B., Abazadeh, B. (2011). An experimental investigation of the bolt clamping force and friction effect on the fatigue behavior of aluminum alloy 2024-T3 double shear lap joint. Materials & Design, 32(8), 4641-4649. https://doi.org/10.1016/j.matdes.2011.04.022.
  31. Motosh, N. (1976). Development of design charts for bolts preloaded up to the plastic range. Journal of Engineering for Industry, 98(3), 849-851. https://doi.org/10.1115/1.3439041.
  32. Şekercioğlu, T. (2013). Makine elemanları çözümlü problemler. Birsen Yayın Dağıtım Ltd. Şti., İstanbul, Türkiye.
  33. Shigley, J.E., Mischke, C.R., Budynas, R.G. (2004). Mechanical engineering design (7th edition). McGraw-Hill, New York, NY, USA.
  34. DIN 2092 (1992). Design of conical disc springs. Deutsches Institut für Normung (DIN). Berlin. Deutsches Institut für Normung (DIN), Berlin, Germany.
  35. GB/T 1972-2005 (2005). Disc Spring. Standardization Administration of the People's Republic of China, Beijing, China.
  36. Wang, B., Yang, Z., Cai, W.Z., Shi, Q.X., Yang, Y.L. (2025). Development and performance assessment of a novel self-centering damper for slotted RC walls. Engineering Structures, 323, 119274. https://doi.org/10.1016/j.engstruct.2024.119274.
  37. BS EN 15129 (2009). Anti-seismic devices. British Standards Institution, London, UK.
  38. Alothman, A., Mangalathu, S., Hashemi, J., Al-Mosawe, A., Alam, M.D.M., Allawi, A. (2021). The effect of ground motion characteristics on the fragility analysis of reinforced concrete frame buildings in Australia. Structures, 34, 3583-3595. https://doi.org/10.1016/j.istruc.2021.09.084.
  39. Ijmulwar, S.S., Patro, S. K. (2024). Seismic design of reinforced concrete buildings equipped with viscous dampers using simplified performance-based approach. Structures, 61, 106020. https://doi.org/10.1016/j.istruc.2024.106020.
  40. Jing, X., Wang, Q., Jiang, M., Shi, Q., Yang, H. (2025). Research on seismic behavior of variable friction damper-RC frame structures. Structures, 76, 108964. https://doi.org/10.1016/j.istruc.2025.108964.
  41. Yang, L., Ye, M., Wu, Z., Dong, J. (2024). Seismic performance of steel frame structures equipped with novel displacement-amplified friction dampers. Structures, 68, 107041. https://doi.org/10.1016/j.istruc.2024.107041.
  42. Yuan, W., Shi, F., Zhang, C., Lie, W., Fang, D., Zhao, D. (2026). Seismic fragility assessment of self-centering braced steel frames with cyclic degradation under mainshock-aftershock sequences. Structures, 86, 111321. https://doi.org/10.1016/j.istruc.2026.111321.
  43. Pall, A.S., Pall, R. (2004). Performance-based design using Pall friction dampers—an economical design solution. 13th world conference on earthquake engineering, Vancouver, BC, Canada, August.
  44. Disaster and Emergency Management Authority (TBEC) (2018). Turkish building seismic code [Regulation No. 20180318M1-2-1]. Disaster and Emergency Management Authority, Ankara, Türkiye.
  45. Disaster and Emergency Management Authority (AFAD) (2018). Turkey earthquake hazard map. Disaster and Emergency Management Authority, Ankara, Türkiye.https://tdth.afad.gov.tr/