DOI QR코드

DOI QR Code

Performance level thresholds for truss moment frames with H-shaped sections

  • Kaichen Ni (School of Civil Engineering, Suzhou University of Science and Technology) ;
  • Guohua Sun (School of Civil Engineering, Suzhou University of Science and Technology) ;
  • Wenxia Yang (Jiangsu Huning Steel Mechanism Co., Ltd)
  • Received : 2026.03.09
  • Accepted : 2026.06.08
  • Published : 2026.08.25

Abstract

In this study, a methodology for determining performance level thresholds of truss moment frames (TMFs) with H-shaped sections was proposed within the framework of performance-based seismic design (PBSD). Numerical analyses were conducted on six groups comprising a total of twenty TMF substructure models using the ABAQUS software. Based on the modified Park-Ang damage model and corresponding damage criteria, the inter-story drift ratio (IDR) limits of TMF structures were determined for the performance levels of Linear Limit, Immediate Occupancy, Damage Control, Life Safety, Limited Safety Range, Collapse Prevention, and Collapse. The effects of six key design parameters-including story height, span length, column section dimension, truss panel width, truss panel height, and diagonal web member configuration-on the damage performance of TMF structures were systematically investigated. Based on the relationship between performance levels and damage indices, the aforementioned performance level thresholds represented by IDR were determined as 0.63%, 1.10%, 1.69%, 2.22%, 2.65%, 3.06%, and 3.45%, respectively. Lastly, the simplified performance objectives for TMFs was proposed, which could provide a design reference for PBSD of TMF structures.

Keywords

Acknowledgement

The work was financially supported by the National Natural Science Foundation of China (No. 52378173), the Natural Science Foundation of Jiangsu Province (No. BK20231343), and the Postgraduate Practice Innovation Program of Jiangsu Province (No. KYCX25-3578).

References

  1. Itani, A.M., Goel, S.C. (1991). Earthquake resistance of open web framing systems. Report No. UMCE 91-21, University of Michigan, Ann Arbor, MI, USA.
  2. Goel, S.C., Itani, A.M. (1994a). Seismic behavior of open-web truss-moment frames. Journal of Structural Engineering, 120(6), 1763-1780. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:6(1763).
  3. Goel, S.C., Itani, A.M. (1994b). Seismic-resistant special truss-moment frames. Journal of Structural Engineering, 120(6), 1781-1797. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:6(1781).
  4. Basha, H.S., Goel, S.C. (1995). Special truss moment frames with Vierendeel middle panel. Engineering Structures, 17(5), 352-358. https://doi.org/10.1016/0141-0296(95)00018-3.
  5. Parra-Montesinos, G.J., Goel, S.C., Kim, K.Y. (2006). Behavior of steel double-channel built-up chords of special truss moment frames under reversed cyclic bending. Journal of Structural Engineering, 132(9), 1343-1351. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:9(1343).
  6. Longo, A., Montuori, R., Piluso, V. (2012). Theory of plastic mechanism control of dissipative truss moment frames. Engineering Structures, 37, 63-75. https://doi.org/10.1016/j.engstruct.2011.12.046.
  7. Longo, A., Montuori, R., Piluso, V. (2012). Failure mode control and seismic response of dissipative truss moment frames. Journal of Structural Engineering, 138(11), 1388-1397. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000569.
  8. Yang, T.Y., Li, Y., Leelataviwat, S. (2014). Performance-based design and optimization of buckling restrained knee braced truss moment frame. Journal of Performance of Constructed Facilities, 28(6), A4014007. https://doi.org/10.1061/JCCOF2.CCENG-4745.
  9. Simasathien, S., Jiansinlapadamrong, C., Chao, S.H. (2017). Seismic behavior of special truss moment frame with double hollow structural sections as chord members. Engineering Structures, 131, 14-27. https://doi.org/10.1016/j.engstruct.2016.10.001.
  10. Jiansinlapadamrong, C., Price, B., Chao, S.H. (2018). Cyclic behavior of steel double-channel built-up components with a new lateral-torsional-buckling prevention detail. Journal of Structural Engineering, 144(8), 04018127. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002125.
  11. Chao, S.H., Jiansinlapadamrong, C., Simasathien, S., Okazaki, T. (2020). Full-scale testing and design of special truss moment frames for high-seismic areas. Journal of Structural Engineering, 146(3), 04019229. https://doi.org/10.1061/(ASCE)ST.1943-541X.0002541.
  12. Ghobarah, A. (2001). Performance-based design in earthquake engineering: State of development. Engineering Structures, 23(8), 878-884. https://doi.org/10.1016/S0141-0296(01)00036-0.
  13. Lee, S.S. (2002). Modelling of steel link beams of short, intermediate or long length. Ph.D. Dissertation, University of Michigan, Ann Arbor, MI, USA.
  14. Chao, S.H., Goel, S.C. (2005), Performance-based seismic design of EBF using target drift and yield mechanism as performance criteria. Report No. UMCEE 05-05, University of Michigan, Ann Arbor, MI, USA.
  15. Sahoo, D.R., Chao, S.H. (2010). Performance-based plastic design method for buckling-restrained braced frames. Engineering Structures, 32(9), 2950-2958. https://doi.org/10.1016/j.engstruct.2010.05.014.
  16. Bayat, M.R. (2010). Performance-based plastic design of earthquake resistant steel structures: Concentrically braced frames, tall moment frames, plate shear wall frames. Ph.D. Dissertation, University of Texas at Arlington, Arlington, TX, USA.
  17. Kharmale, S.B., Ghosh, S. (2013). Performance-based plastic design of steel plate shear walls. Journal of Constructional Steel Research, 90, 85-97. https://doi.org/10.1016/j.jcsr.2013.07.029.
  18. Arjmandi, K., Estekanchi, H., Vafai, A. (2009). Correlation between structural performance levels and damage indexes in steel frames subjected to earthquakes. Scientia Iranica, 16(2), 147-155. https://doi.org/10.24200/sci.2017.2376.
  19. Park, Y.J., Ang, A. H.S. (1985). Mechanistic seismic damage model for reinforced concrete. Journal of Structural Engineering, 111(4), 722-739. https://doi.org/10.1061/(ASCE)0733-9445(1985)111:4(722).
  20. Powell, G.H., Allahabadi, R. (1988). Seismic damage prediction by deterministic methods: concepts and procedures. Earthquake Engineering & Structural Dynamics, 16(5), 719-734. https://doi.org/10.1002/eqe.4290160507.
  21. Valles, R.E., Reinhorn, A.M., Kunnath, S.K., Li, C. (1996). IDARC2D version 4.0: A program for the inelastic damage analysis of buildings. Technical Report NCEER-96-0010, National Center for Earthquake Engineering Research, Buffalo, NY, USA.
  22. Sun, G.H., Gu, Q. (2013). Performance level thresholds and damage evaluation for steel plate shear walls. Journal of Building Structures, 46(4), 46-56.
  23. FEMA-356 (2000). Pre-standard and commentary for the seismic rehabilitation of buildings. Federal Emergency Management Agency, Washington, D.C., USA.
  24. SEAOC Vision 2000 (1995). A framework for performance-based engineering. Structural Engineering Association of California, Sacramento, CA, USA.
  25. FEMA 273 (1996). NEHRP commentary on the guidelines for the rehabilitation of buildings. Federal Emergency Management Agency, Washington, D.C., USA.
  26. ATC-40 (1996). Seismic evaluation and retrofit of concrete buildings. Applied Technology Council, Redwood City, CA, USA.
  27. Taku, M., Hirokazu, I. (2002). Demand spectra of yield strength and ductility factor to satisfy the required seismic performance objectives. Proceedings of the sewc 2002 structural engineers world congress, Yokohama, Japan, October.
  28. CEB-FIP (2003). Displacement-based seismic design of reinforced concrete buildings. Bulletin 25, International Federation for Structural Concrete, Lausanne, Switzerland.
  29. GB 50010 (2010). Code for design of concrete structures. National Standard of the People's Republic of China, China Architecture & Building Press, Beijing, China.
  30. Li, H.X. (2014). Research and application of elastoplastic damage model for ductile metals. Doctoral Dissertation, Xi'an University of Architecture and Technology, Xi'an, China.
  31. SAC (1997). Protocol for fabrication, inspection, testing and documentation of beam-column connection test and other experimental specimens. Report No. SAC/BD-97/02, SAC Joint Venture, Sacramento, CA, USA.
  32. Li, Y.Q. (2024). Research on hysteretic behavior of H-shaped steel column-composite truss beam connections. Master's Thesis, Suzhou University of Science and Technology, Suzhou, China.
  33. Yahyaabadi, A., Gholami, M., Garivani, S. (2026). Probabilistic seismic demand assessment of special truss moment frames with Vierendeel panels under geometric variations. Scientific Reports, 16(1), 14570. https://doi.org/10.1038/s41598-026-42239-y.