한국콘크리트학회:학술대회논문집 (Proceedings of the Korea Concrete Institute Conference) (Proceedings of the Korea Concrete Institute Conference)
한국콘크리트학회 (Korea Concrete Institute)
- 반년간
과학기술표준분류
- 재료 > 세라믹재료
한국콘크리트학회 2001년도 봄 학술발표회 논문집
-
The purpose of this study is to present a basic data about the workability of high strength concrete to apply to a field of construction work. The main parameters are as follows; environmental temperature, elapsed time and the use of mineral admixture or not under the same mixing proportions. From the result, Adding amounts of superplasticizer to get a target slump were different in the respective temperature condition. Slump loss according to elapsed time was influenced by environmental temperature. the amount of superplasticizer and the slump loss were decreased by using mineral admixture(garnet powder) and by making concrete under lower temperature.
-
This paper report the effects of mix ingredients on the modulus of elasticity of high-strength concrete. The test of 284 cylinder specimens are conducted for type I with 10% replacement of fly-ash cement concretes. Different water-binder ratio, amounts of water and coarse aggregate as variables were investigated. And also analyzed it statistically by using SAS.
-
This paper presents the improved elastic modulus equation more appropriate to predict the modulus of elasticity of structural elements designed and made by high-strength concrete. To propose the elastic modulus equation, more than 300 laboratory specimen tests having the range of 5n to 800kgf/
$cm^{2}$ in concrete compressive strength were conducted and analyzed statistically. The equation derived in terms of empirical constant, the elastic moduli of coarse aggregate and mix proportions. Comparison of the proposed elastic modulus equation with the previously suggested equations in the ACI363R, and New-RC were also presented to demonstrate the applicability to practice. -
The use of fly ash in cement and concrete industries has many benefits including engineering, economic, and ecological aspects. However, it has a disadvantage of low strength development, especially at early ages. In this study, in order to overcome this problem, the early strength accelerating agent(
$NA_{2}$ $SO_{4}$ ) was selected and applied to the production of high strength concrete(HSC) containing fly ash. It was found that the compressive strength of fly ash concrete incorporating TEX>$NA_{2}$$SO_{4}$ has greater than that of concrete containing fly ash only until 7 days after casting. From the microstructural point of view, ettringite increased and pores decreased in fly ash concrete incorporating TEX>$NA_{2}$$SO_{4}$ , leading to the development of early age strength. It was also found that the velocity vs. strength relationship of HSC is considerably different from that of low-strength concrete(LSC). Therefore, in order to predict early age strength of HSC, a estimation equation different from that for LSC is needed. -
Using waste glass in concrete can cause crack and strength loss by the expansion of alkali-silica reaction(ASR). In this study, ASR expansion and properties of strength were analyzed in terms of brown waste glass content, and fibers(steel fiber, polypropylene fiber) and fiber content for reduction ASR expansion due to waste glass. In this accelerated ASTM C 1260 test of waste glass, pessimum content can not be found. Also, when used the fibers with waste g1ass, there is an effect on reduction of expansion and strength loss due to ASR between the alkali in the cement paste and the silica in the waste glass. Specially, adding 1.5 vol.% of steel fiber to 20% of waste glass the expansion ratio was reduced by 40% and flexural strength was developed by up to 110% comparing with only Waste glass (
$80^{\circ}C$ $H_{2}$ O curing). -
Influencing factors on flexural toughness of ring-type fiber reinforced concrete(RSFRC) are investigated. An experiment proceeding ASTM C 78 is peformed to make a comparison between ring-type fibers and double-hook type fibers. Most specimen with ring type fibers have failed by the cone type failure, while discrete hook type fibers have failed by fiber pullout. For the hook-type fiber reinforced concrete(SFRC), the first crack load increases, as the fiber mixing volume increases. Aspect ratio(fiber length/fiber diameter) is critical for hook type fibers, so the flexural toughness increases significantly, as the length of fiber increases. However, for the ring type, the toughness indices Increase as the number of fibers in the specimen increases. Since there is no bond problem between the ring fiber and the concrete matrix, the aspect ratio does not affect the performance of the composite material with the newly developed steel fibers. Influencing factors with respect to flexural toughness RSFRC were observed to be ring diameter, diameter of steel fiber and fiber content.
-
It is now common practice to strengthen reinforced concrete beams by steel plates to their tention surfaces. Such plated beams are designed for flexure using conventional prediction equation and assumption that full bond will be developed between the concrete and the plates. Very advanced design rules have already been developed at the University of Adelaide for adhesive bonding steel plates to reinforced concrete beams in order to prevent premature debonding. This work on plated continuous reinforced concrete beams is to determine experimentally whether these design rules, that were developed for steel plated simply supported beams, could be applied to steel and FRP plated continuous beams. This paper also suggests how to increase the ductility of plated beams.
-
Steel plate or fiber composite plate are mainly used in externally bonding method. Shear strengthening by externally bonding method is to confirm shear safety and to avoid brittle failure. In case of strengthening by externally bonding method, a failure of structure occurs frequently due to delamination between strengthening plate and concrete. Therefore, it is important to consider the delamination in the strengthening design. The objective of this study is to propose a modified shear strength evaluation by considering the delamination. The delamination criteria of strengthening plate is established by the ultimate strain and shear stress. And shear strength of RC beams is proposed in terms of the delamination criteria. The proposed shear strength is compared with test results and verified through the comparison.
-
This paper investigates the flexural behavior of reinforced concrete beams strengthened with externally bonded fiber reinforced plastic (FRP) sheets is investigated in this work. FRP is attractive for strengthening the RC beams due to its good tensile strength, low weight, resistance to corrosion, and easy applicability. A simple and direct analytical procedure for evaluating the ultimate flexural capacity of FRP strengthened reinforced concrete (SRC) beams is presented using the equilibrium equations and compatibility of strains. Upper and lower limits of FRP sheet area to ensure the ductile behavior are established. A parametric study is conducted to investigate the effects of design variables such as sheet area, sheet stiffness and strength, concrete compression strength, and steel reinforcement ratio. The analytical procedure is compared with results of experimental data available in the literature.
-
The concrete bridge decks are in need of replacement and rehabilitation due to decreasing load carrying capacity. In this study, to propose a strengthening technique that improves usability and structural performance of the bridge deck and to propose an efficient strengthening design technique which satisfies both the strength End serviceability of the bridge deck, this paper shows the failure characteristics of the strengthened bridge decks and proposes an empirical yield criterion. Therefore, strengthening efficiency was proposed based on the experiment and yield line analysis result. The yield line theory which adopts the modified criteria of Johansen is considered to predict the ultimate strength about all strengthening material(Carbon Fiber Sheet, Carbon Fiber Rod, Grid Type Carbon Fiber).
-
Reinforced concrete have defect in durability due to carbonation, freezing and thawing, and penetration of chloride ions with time in spite of superb structure. Especially steel corrosion in concrete due to penetration of chloride ions have result in a marked decline in service life. The principal purpose in this study is to see effect of sacrificial anode cathodic system, one of the electrochemical methods in order to the control of steel corrosion in concrete. There are chloride content in concrete in cracked and no cracked specimen with cathodic protection. To recognize the effect of sacrificial anode cathodic protection, Instant-off potential are measured. We have the excellent effect for control steel corrosion adaption sacrificial anode cathodic system.
-
This study is to develop the end anchorage of external steel reinforcement of RC slab bridges. External prestress method using the existing steel is that When the anchorage is installed in slab end, a plenty of anchor bolts were required because the only tangential stress of anchor bolt received a tendon force. Then, for this reason, the wide end anchorage was required and the shape was complicate. But this reinforcement method using method that inserts anchor key at concrete surface cut a groove gets big internal force comparing to the anchorage using existing anchor bolt. Furthermore, the number of anchor bolt for installing apparently will be reduced, and the operation will be convenient because a small anchorage of a simple shape will be received a great tendon force
-
This paper presents experimental results for the confining characteristics of cylinder with center-hole and spiral reinforcements. The experiments have been conducted for the specimens with primary variables i.e., spiral reinforcement ratio and diameter of center-hole which affect the compressive strength and stress-strain relationship. Through this research, it was found that the compressive strength and ductility were increased with the ratio of spiral reinforcement because the lateral expansion of the concrete inside the spiral was restrained by the spiral, but dependent on the size of center-hole.
-
The IPC(Incremental Prestressed Concrete) which is gradually introducing the tensile force by tendons has been recently developed for reducing the effective depth of PSC bridges. As well known, concrete experiences long-term deformation such as creep and drying shrinkage, and the prediction of the long-term behavior of concrete bridges is essential for both safety and serviceability aspects. This paper was analysed the long-term behavior of a continuous 2-span IPC girder bridge taking into consideration of creep, drying shrinkage and the time of tensile force introduction. As results, the shrinkage of slab concrete increases the negative moment at interior support, and the The difference of concrete ages between slab and girder increases the camber. The effect of initial tensile force is larger than the effect of secondary tensile force in the tendons.
-
The two-girder composite bridge has the girder space of more than 5m, for special case, over than 15m. Therefor, the design and construction of this bridge system require new approaches. To ensure the structural safety, the deck depth should be increased. Therefore, the economically designed deck system is necessary for th two-girder bridge. This study is the first step to develop the deck system for two-girder bridges. In this study, a literatute survey is performed to develop a new deck system for two-girder type of bridges. By considering the characteristics of two-girder bridge system, a cast-in-place PSC deck is proposed for the two-girder bridges. To examine structural behavior and safety of the proposed PSC deck, three real scale partition deck(3m
$\times$ 5m) are tested under the static loading. In the test, the failure mode and behavior of each specimen, and ultimate load carrying capacity of the two-girder-bridge deck are identified. -
A general procedure to implement the sensitivity analysis of PSC flexural members is proposed based on the analytical calculation of the gradients of stresses and strains with respect to the 21 design variables in a closed format. The formulation covers the long term losses including concrete creep, shrinkage, and PS steel relaxation as well as load effects. The derived formulation is applied to the rectangular section PSC beam with prestressing and nonprestressing steels for the sensitivity analysis. The analytically calculated sensitivity results are compared with those numerically calculated.
-
A existing design method of PSC girder bridges, according to total service loads, stress required tendon force at a time. Because this design method increases beam depth, design of long span is difficult. However, As UC girder stressing at difficult loading stages reduces sectional depth of PSC girder, both design and operation of long span bridges is possible. so, this study analyzes the effect of design parameter (Girder Strength, Girder Spacing, Span Length, Joint Strength) on the beam depth of IPC girder continuous bridges, and shows sectional depth of UC girder for design of long span bridges. According to analysis, when a continuous bridges of same length span is at strength of joint over strength of girder of 600kg/
$cm^{2}$ , a change of beam depth is observed and when a continuous bridges of different span length is at strength of joint below strength of girder of 600kg/$cm^{2}$ , a change of beam depth is observed. In two case, a change of beam depth is mostly observed over strength of girder of 350kg/$cm^{2}$ according to analysis of deflection data, a continuous bridges of IPC girder is nearly satisfied. -
Total number of seven experimental specimens of size 4.6m
$\times$ 2.4m are designed in full scale with due considerations given to the constructability as well as economic applications. Each specimen is made with different shapes of trusses or hooks along the interfacial surface between precast panel and topping concrete to maintain appropriate shear resistance. Structural performances in terms of strength and ductility under flexural load are examined for each specimen with different types of interfacial shear resistance reinforcements. Experimentally obtained flexural strength are also compared with those of analytical predictions. Based on experimental and analytical studies, design equations are suggested for the developed precast prestressed concrete half-slab systems. -
The objective of this study is to investigate the behavior of 1/12 scale upper-wall lower-frame reinforced concrete structure subjected to earthquake excitations. For this purpose, Taft N21E earthquake accelerogram was simulated by using 4m
$\times$ 4m shaking table. When the input acceleration is compared to that of output, it was found that simulation of shaking table is satisfactory. From the test results with peak ground acceleration(PGA) 0.22g, which corresponds to 0.11g in prototype by the similitude law, it can be observed that the model responded in elastic behavior and that large interstory drift occurred at the lower part of the structure. -
With the increase in the use of High-Strength Concrete(HSC) despite the its weakness like brittle characteristic, it is important to improve the performance of HSC columns, nowadays. Therefore, it is common to use higher strength steel in HSC for the purpose of ductility and strength improvement. This experimental study was set up to investigate the inelastic behavior of HSC(700kg/
$cm^{2}$ ) columns subjected to combined axial and repeated lateral loads. Effects of key variables such as the volumetric ratio of transverse reinforcement, tie configuration and tie yield strength are studied in this research program. Test results indicate that inelastic response of HSC columns improve with proper confinement of core concrete. Increasing the amount of transverse reiuorement results in increased ductility. -
Concrete has excellent characteristics as building material and functions relatively well; but it has many problems concerning too heavy weight of the structures. Accordingly, it is the assignment for study in the part of building materials to lighten and high strengthen the weight of concrete structures in order to improve those weak Points; and it seems one of the representative solutions to develop the high strength lightweight aggregate concrete. Based on the experimental results presented, the following conclusions are drawn. The concrete with unit weight of 1.96~2.03t/
$m^{2}$ , compressive strength of 322~431kgf/$cm^{2}$ was gained. So, it appears that the lightweight aggregate concrete will be useful for low unit weight and high strength lightweight aggregate concrete. In the end, to manufacture artificial lightweight aggregate concrete for construction work is necessary to develope artificial aggregate which has improved performances physically. -
The purpose of this study is to investigate the enhancement of shear capacity according to steel fiber contents in RC short columns. Lateral force resistance test was performed with the parameters of steel fiber contents in concrete volume. From the test results, shear and ductility capacity was improved with steel fiber contents Increased. In addition, an optimal steel fiber content was evaluated as a 1.5 % of concrete volume.
-
Punching shear in concrete slabs is a serious problem in certain structural systems, such as flat slab. In this study, mechanical improvement between specimens which are unstrengthened and strengthened with steel plate and fiber panel is experimentally investigated. The strengthened bridge deck specimens had increment of strength and broke down with punching shear failure. Strengthening ratio should be considered to restraint punching failure.
-
This study concerns crack effect on concrete anchor system and prediction of tensile capacity, as governed by concrete cone failure, of single anchors located at center of concrete specimen. To Investigate crack effect three different types of crack such as crack width of 0.2mm and 0.5nm, crack depth of loom and 20cm, and crack location of center and biased point were simulated. The static tensile load was subjected to 7/8 in. CIP anchor embedded in concrete of strength 280kg/
$cm^{2}$ . Tested pullout capacity was compared to prediction value by each current design method (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CC Method), In these comparison CC Method and ACI revision showed almost same value in uncracked concrete specimen, however in cracked concrete CC Method showed conservativeness. Therefore the design by ACI 349 revision is recommended for the safe and economic design. -
Based on the three reinforced concrete panel tests, a softened stress-strain curve of concrete subjected to reversed cyclic loading is proposed. The proposed model consists of seven stages in the compressive zones and six stages in the tensile zones. The proposed model is verified by comparing to the test results.
-
The objective of this study is firstly to frame up the seismic safety of concrete gravity dams. It is necessary to analyze seismic response and evaluate seismic performance of concrete gravity dams during earthquake. In this study, seismic damage and dynamic analysis of concrete gravity dams using SAP2000 program are peformed. Additional dynamic water pressure due to earthquake was considered as additional mass for numerical seismic analysis. But, further research will be necessary for the seismic stability of dams.
-
In this study, ultimate strength of concrete deep beams with an opening is predicted by using Strut-and-Tie Model with a new effective compressive strength. First crack occurs around an opening by stress concentration due to geometric discontinuity. This results in decreasing ultimate strength of deep beams with an opening compared with general deep beams. With fundamental notion that ultimate strength of deep beam with an opening decreases as a result of reduction in effective compressive strength of a concrete strut, an equivalent effective compressive strength formula is proposed in order to reflect ultimate strength reduction due to an opening located in a concrete strut. An equivalent effective compressive strength formula which can reflect opening size and position is added to a testified algorithm of predicting ultimate strength of concrete deep beams. Therefore, ultimate strength of concrete deep beam with an opening is predicted by using a simple and rational STM algorithm including an equivalent effective compressive strength formula, not by finite element analysis or a former complex Strut-and-Tie Model
-
Numerical procedures for the geometrically nonlinear finite element analysis of prestressed concrete shell structures under tendon-induced nonconservative loads have been presented. The equivalent load approach is employed to realize the effect of prestressing tendon. In this study, the tendon-induced nonconservative loads are rigorously formulated into the load correction stiffness matrix(LCSM) taking the characteristics of Present shell element into account. Also, improved nonlinear formulations of a shell element are used by including second order rotations in the displacement field. Numerical example shows that beneficial effect on the convergence behavior can be obtained by the realistic evaluation of tangent stiffness matrix according to the present approaches.
-
This paper presents truss model that can be used to determine the deformation as well as strength of RC members. This model is constituted to address plastic hinge rotation at tile deformation concentrated regions under severe lateral load. The behavior of each element of truss model is evaluated on the basis of stress field analysis. The deformation is obtained by combining element deformations with joint rotation. Initial strength is calculated at the first failure of any element, and strength deterioration after failure depends on the strength reduction of this element. The proposed model will provide useful tools in seismic design of ductility-required members.
-
The aim of this study is to present a practical and simple method for decision of ultimate failure mode of high-strength concrete beam members, based on interaction between shear strength and displacement ductility. Four tests were conducted on full-scale beam specimens having concrete compressive strength of 410kgf/
$cm^{2}$ . Prediction of failure mode from presented method and comparison with test results are also presented -
The objective of this study is to examine the fracture characteristics of concrete at early ages such as critical stress intensity factor, critical crack-tip opening displacement, fracture energy based on the concepts of the effective-elastic crack model and the cohesive crack model. A wedge splitting test for Mode I was performed on cubic wedge specimens with a notch at the edge. By varying strength and age, load-crack mouth opening displacement curves were obtained and the results were analyzed by linear elastic fracture mechanics. The results from the test and analysis showed that critical stress intensity factor and fracture energy increased, and critical crack-tip opening displacement decreased with concrete age from 1 day to 28 days. The obtained fracture parameters at early ages may be used as a fracture criterion and an input data for finite element analysis of concrete at early ages.
-
In this paper, the properties of concrete using recycled fine aggregate are anlyzed. Five different contents. 0%, 40%, 60%, 80% and 100% of recycled concrete were used for this study. At curing 280days, compressive strength, dry-shrinkage, static modulus of elasticity and poission's ratio have been tested according to replacement ratio of recycled fine aggregates.
-
Cast-in-place foamed concrete is a high porous material placed as base the layer of mortar screeds in the panel heating system, so the quality of mortar is affected by it. Therefore, this study is aims to investigate how the absorption characteristics of foamed concrete influences on mortar screeds according to the foamed ratio-62%, 67% and 72%- and the surface treatments of foamed concrete-water and acrylic emulsion primer spray, etc. The result of this study shows that water-spray in the surface of foamed concrete has a good effects to reduce mortar cracking.
-
In this paper, tests are carried out in order to investigate the validities of anti-freeze agent, which is developed using waste coolant and existing anti-freeze agent through previous study, under various W/C and contents. According to test results, adequate dosage of developed anti-freeze agent shows positive performance in slump, air content and chloride contents in the mixture of 40% and 50% of W/C, accelerates setting time and drops the freezing temperature of concrete. Meanwhile, in the region of 30% of W/C, followings can be indicated that increasing the contents of anti-freeze agent leads to reduce fluidity, rapid setting and excessive chloride contents. Improved strength gain is shown when anti-freeze agent is used with in 8%.
-
The objective of this study is to investigate growth of grass planted with planting concrete using recycled aggregste. Planting concrete blocks are constructed on the roof of existing building. Temperature variation according to planting concrete method are also investigate. According to test results, it shows that grass grows very well under planting concrete method. When planting concrete method is applied, it brings about temperature reducing effects about 1~
$2^{\circ}C$ at inner part of the buildings at cooling required period compared to that with existing roof, and at heating required period temperature insulating effects about 2~$4^{\circ}C$ . -
The objective of this study is to investigate the thermal conductivity of cement mortar for apartment housing floor using expansive admixture, copper fiber, cower lathe, hollowed aluminum plate. According to test results, temperature at point (a) located above heating pipe does not show significant variation with age, and temperature at (b), which is located at the finishing surface above heating pipe, and temperature at (c), which is located at center surface between heating pipe has remarkable change. Temperature distribution sat (b) are in order for, structure containing copper fiber>plain structure>structure containing hollowed aluminum plate>structure containing expansive admixture. Temperature distribution, shows high tendency in order for, structure containing copper fiber>structure containing copper lathe>structure containing hollowed aluminum plate>plain structure>structure containing expansive admixture. (a) estimation of temperature distribution is determined with the variation of temperature between (b) point and (c) point during 60 minutes heating.
-
Recently, as industrialization is rapidly growing and the standard of life is rising, the quantities of waste glasses have been hastily increased and most of them are not recycled but abandoned. It cause some problems such as the waste of natural resources and environmental Pollution. Therefore, this study was conducted basic experimental research to analyze the possibilities of recycling of waste glasses(crushed waste glasses outbreaking from our county such as brown, green, colorlessness) as fine aggregates for concrete. Test results of fresh concrete, slump and compacting factors decrease because grain shape is angular and air content increase due to involving small size particles so much in waste glasses. Also compressive, tensile and flexural strengths decrease with increase of the content of waste glasses. In conclusion, the content of waste glasses below 30% is reasonable
-
The objective of this study is to compare compressive strength and rebound number of Schmidt hammer of concrete using basalt aggregate to that using granite aggregate. And is to provide the reference data on the standardization of nondestructive test of concrete. According to test results, compressive strength of concrete using basalt aggregate is highly estimated under the same rebound number compared to that using granite aggregate about 5~15%. It is urgently that newly suggested estimation formula of compressive strength using basalt aggregate must be prescribed because estimation formula of compressive strength of concrete using basalt aggregates overestimates the strength compared to that using granite aggregate.
-
In this study, the physical and mechanical characteristics of Bottom-ash exhausted from each of steam power plant was considered. The comparative objects were Bottom-ash in which a lot of powder contained and that in which less than that relatively contained. The difference in quantity of powder showed different effect on the character of flow. This study was undertaken on the use of Bottom-ash as a fine aggregate, and showed the optimum mixing and the character of flow according to each rate. And this study showed the quantity of water and binder added in different Bottom-ash was differently used.
-
The purpose of this study is to evaluate basic properties of artificial aggregate using concrete sludge according to mixing ratio. Cement, waste phosphogypsum and Powder of blast furnace slag are used with binder of artificial aggregate. Specific gravity, absorption are tested for basic property, and impacting, abrasion and crushing tests are done for characteristics of strength on the aggregate, including comparison with crushed stone. Bry specific gravity was ranged about 1.16 to 1.30 the test result of the aggregates and shape is round In the result of tests, it is concluded that qualities of the aggregates using concrete sludge are slightly lower than crushed stone but it is similiar with sintering artificial lightweight aggregate in high temperature.
-
Recycling of coal combustion by-product(Ash) are becoming more improtant in the utilization business as a result of the increased use of NOx reduction technologies at coal-fired power plants. current disposal methods of these by-products create not only a loss of profit for the power industry, but also environmental concerns that breed negative public opinion. Since inherent characteristics make these by-product suitable for building materials, several types of artificial aggregates and construction bricks are manufactured and tested to verify the engineering properties.
-
The development of automobile, vessel, rail road, and machine industry leads increase of foundry production used as their components, which cause a by-product, waste foundry sand (WFS). The amount of the WFS produced in Korea is over 900,000 ton a year, but most WFS buries itself and only 5~6% WFS is recycled as a material in construction materials. In this study, WFS is used as a fine aggregate for concrete. Five types of concretes aimed at the specified strength of 240
$\pm$ 10 kgf/$cm^{2}$ , air contents of 4.5$\pm$ 1% and slump of 12$\pm$ 1.5cm were mixed with washed coarse seashore sand(WFS) in which salt was removed and then optimum mix proportion of concrete was determined. Moreover, basic properties such as setting time, workability, bleeding and slump loss of the fresh concrete with WFS were tested and compared with those of the concrete mixed without WFS. In .addition, both compressive strength of hardened concrete at each ages and tensile strength of it at the age of 28 days were measured and discussed. -
This study concerns the cement-solidification/stabilization of the waste with high concentration heavy metals. Compressive strength and leaching test of heavy metals were evaluated for ing types of cements and the effect of the additives of Hauyne clinker and slag were also cussed. Using ordinary portland cement, rapid hardening portland cement and the cement with additives solidification materials, it shows that the strength and stability of concrete is satisfactory and superiority is in the order of rapid hardening portland cement > the cement with additives > nary portland cements.
-
In road pavements, it is known that cement concrete pavement has superior durability, safety in compared with asphalt concrete pavement. But in reparing pavement cement concrete pavement is not usually applied because of the length of time while the road is interrupted when using Ordinary and Rapid-hardening Portland Cement. And Super High Early Strength Cement and Ultra Super High Early Strength Cement are not favorable for ready mixied concrete because of rapid setting time, high slump loss and other restrictions. We aim to develope specific cement and concrete developing 1 day strength of over 300 kg/
$cm^{2}$ to open the road within one day and workable time is maintained over 1 hour that can be used as ready mixed concrete. In this study, we Produced cement using rapid-hardening cement, Hauyne clinker, anhydride gypsum and accelerator and studied on its properties. The concrete strength was over 300 kg/$cm^{2}$ at 1 day and 550 kg/$cm^{2}$ at 28 day and workable time was maintained for over 1 hour. -
This study was _ performed of rheological properities for slurry of ultra fine cement using admixtures. An experimental parameter is W/B and superplasticizier ratio and different water-soluble polymers. As a results, it's strongly appeared to rheological properties of slurry as particles ratio, it's know that rheological properities affected by admixtures.
-
The objective of this study is to find out effects of horizontal vibration on the compressive strength for 7days and 28 days cured concrete specimens according to the variation of fine aggregate modului, vibration velocities, and times began to vibrate. Four kinds of fine aggregate modului(40, 42, 45, 47%), three of vibration velocities(0.25, 0.5 0.1kine(cm/sec)), and four of times(0, 3, 6, 9hrs after concrete casting) were chosen as the experimental parameters in this study, the vibrations were applied for 30 minutes in each case. From this study, it could be seen that the most increase of compressive strengths were obtained in case of 47% fine aggregate modulus, and 0.25kine of vibration velocity, but the strength was decreased when vibrated after 9hrs from concrete casting.
-
The cost of producing ready mixed concrete(remicon) has increased due to the rising cost of raw materials for concrete and transportation caused by the upturn of oil price. In contrast, its orders have also decreased due to the recession of the construction industry. In addition, the cost of delivery has decreased owing to the excessive competition among manufacturing companies, so manufacturing companies began mixing ground granulated blast-furnace slag or fly ash to lower the cost. However, there is no way to determine whether the strength of the concrete using the admixture is satisfied or dissatisfied with design strength at the early age. The purpose of this study is dedicated to early strength estimation of concrete mixed with an admixture, ground granulated blast-furnace slag.
-
Recently new practical use way of industry product is required. In this study, to find flowing property of slump, unit weight, the air amount, compressive strength etc. Compressive strength 240, 270kgf/
$cm^{2}$ , slump 8$\pm$ 2.5(I), 152$\pm$ .5(II)cm, mixing ratio of copper smelting slag decided by 0, 25, 50, 75, 100% gradually, The result of this study was follows ; 1. Unit weight increased 2.2%~4.4% according as mixing ratio of copper smelting slag increases. 2. Slump increased about 2~5% as the mixing ratio increased gradually 3. Compressive strength was increased about 4~28% in copper smelting slag mixing ratio 25~50% and 8~20% decreased more than mixing ratio 75%. -
It is generally observed that steel fiber reinforced concrete with traditional straight steel fibers overcomes brittle nature of plain concrete by failure mechanisms by fiber pull-out rather than fiber rupture resulting from fiber yielding or concrete fracture at failured surface. Ring type steel fibers in concrete which is confined in concrete matrix and has better orientation, thus, lead to fiber yielding and concrete fracture as well as increase of flexural behavior of concrete more efficiently, Comparative experimental study is performed in order to measure the relative efficiencies of steel fiber reinforced concrete reinforced with two different fibers. It is found that better toughness is obtained from the ring type steel fiber reinforced concrete than from straight steel fiber reinforced concrete under flexural loading.
-
Fractal geometry is a non-Euclidean geometry which has been developed to quantitative analysis irregular or fractional shapes. Fractal dimension of irregular surface has fractal values ranging from 2 to 3 and of irregular line profile has fractal values ranging from 1 to 2. In this paper, quantitative analysis of crack growth patterns during the fracture processing of fiber-reinforced cement composites based on fractal geometry. The fracture behaviors of fiber reinforced mortar beams subjected to three-point loading in flexure. The beams all had a single notch depth, but varing volume fractions of polypropylene, cellulose fibers. The crack growth behaviors, as observed through the image processing system, and the box counting method was used to determine the fractal dimension, Df. The results showed that the linear correlation exists between fractal dimension and fracture energy of the fiber reinforced cement mortar.
-
This study is to investigate properties of high strength.high flowing concrete using blast-furnace slag in temperature conditions of 5, 10, 15 and
$20^{\circ}C$ . The result of this study can be summarized as follows. 1) The use of blast-furnace slag leads to decrease of air content and increase of fluidity in the fresh concrete. 2) The early compressive strength of high strength.high flowing concrete containing blast-furnace slag is lower than the case with portland cement only. 3) The compressive strength development of incorporating in the concrete is poor at low temperature below about$15^{\circ}C$ . -
Reinforced concrete is, in general, known as a high durability material due to a strong alkalinity of cement. Probable concrete cracks could incur steel corrosion of RC structures and then could easily deteriorate the concrete durability, which can be fully secured by a systematic quality control for the construction of concrete structures. For the corrosion protection of reinforcing steels in concrete, however, current design specifications of concrete cover depth do not in-depth consider the effect of the cracks as well as the chloride content of RC structures. Therefore, appropriate provisions for concrete cover depth should be coded by considering the influence of concrete cracks on the corrosion of reinforcing steels. The objective of this research is to investigate pertinent cover depth, which can prohibit rebar corrosion, on the basis of experimental corrosion measurements of reinforcing steels on crack characteristics such as the width, depth and frequency of concrete cracks.
-
The cement concrete pavements are designed twenty years of performance life in Korea. At the present time, some expressways have been elapsed seventy percent of performance life which are detecting local failures. The most repair methods using to repair failures are partial depth repair and full section repair. These methods are most important bonding strength between rapid curing materials and substrate concrete pavements. This study was performed to evaluate bonding strength of the composites section made of rapid curing material and substrate concrete pavements. The pull-out tester was used to test bonding strength for the composites section made of each materials. In the results of the test, the bonding strength values of the epoxy mortar and acrylic mortar are higher than those of the other materials. The performance life of repaired section is affected by various factor. The bonding strength of bonded composites section may be affect the performance life, significantly.
-
The purpose of this study is to develop the repair system for RC members with damaged by rebar corrosion using new corrosion inhibitor which was high nitrite content. In the experiments, the acceleration corrosion test of rebar was conducted using the specimen which was applied by various repair system. As a result, it was confirmed that the new repair system without concrete patching had high anti-corrosion property compared with other repair systems and was very effective as a spray type corrosion inhibitor in concrete containing chloride (0.1% of NaCl).
-
The repairing technique of surface wrapping concrete structural members using fiber composite sheet have been widely used. The research efforts have been limited to studying relative strength increase of repaired concrete structures rather than ductility improvement based on composite material effect and the interface effect between composite and concrete. The compression tests of CFS(carbon fiber sheet) reinforced concrete specimens with various cross-sectional shapes and laminate angles have been peformed. FEM algorithm considering various parameters will be performed based on the obtained data. The results will be discussed in detail.
-
The purpose of this study is to investigate toughening of unsaturated polyester resin by addition of polyuretane liquid rubber. In general, unsaturated polyester resin has strong brittleness in spite of its high strength Therefore; it is difficult to use unsaturated polyester mortar for the place where impact resistance is demanded. In this study, it was evaluated strength and Gf by using to polyurethane liquid rubber. As a result, the toughness of unsaturated polyester mortar was increased by polyuretane liquid rubber.
-
This paper presents the experimental result of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector. Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, arrangement of shear connector, thickness of wall, shear span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.
-
This paper presents a nonlinear analysis technique with slip, the effects of slip modulus and composite action by shear connector on behavior and capacity in composite structure of sandwich system. As a results of this study, it proved that the slip modulus, in case of shear behavior, seldom influence load-resistance capacity such as yield and ultimate load, but in case of flexural behavior, it appropriately influence load-resistance capacity because of stress redistribution by slip. In case of flexural behavior, analysis result for perfect-composite results in over-estimation and perfect-slip results in under-estimation on behavior and capacity. Therefore, it is desirable to model steel-concrete interface with partial-composite. The effects of slip on behavior and capacity are less in case of positive composite than loosely composite, and it proved that composite action by shear connector improve the load-resistance capacity of this system.
-
Exposed concrete execution is utilized insufficiently due to surface honecomb and undesirable appearance by entrapped air when existing placing method is applied. Therefore, surface glossing and impact properties of cement mortar incorporating fiber glass net blast furnace slag, expansive admixture and Polypropylene fiber are investigated in order to develop precast exposed concrete pannel by dry construction method. The kinds of the forms, placing method and admixture contents are varied. According to test results, surface glossing decrease with elapse of age. Considering the form kinds, surface glossing with acryle + astage shows the best performance. Placing horizontally shows positive results in reducing surface defects such as honecomb. Impacting resistance shows the best performance when glass fiber net applied, due to the enhance in toughness and absorption of impact.
-
Microstructural characteristics such as hydrates and porosity greatly influence the development of concrete strength. In this study, a strength estimation model for early-age concrete considerig, the microstructural characteristics was proposed, which considers the effects of both an increment of degree of hydration and capillary porosity on a strength increment. Hydration modeling and compressive strength test with curing temperature and curing ages were carried out. By comparing test results with estimated strength, it is found that the strength estimation model can estimate compressive strength of early-age concrete with curing ages and curing temperature within a margin of error.
-
To investigate factors influencing the effective width of. SRC column-steel beam joint resisting the moment as strut, six specimens are designed and tested. Parameters in the test are column width, beam height and horizontal tie within beam depth. From the test, using either wide column width or ties, strength and stiffness of joint were developed. The lower beam height the specimens showed the lower moment.
-
Preliminary experimental results are reported on the response of reversed T type linking reinforced concrete shear wall. Different layouts of coupling beams were tested and stiffness degradation and energy dissipation of coupling beams were evaluated. Diagonally reinforced coupling beams with slab showed larger ductility and larger amount of energy absorption to be attained compared with conventionally reinforced concrete coupled beams.
-
This paper is investigated the coupling effect in slab-wall structural system. An experimental investigation of reinforced concrete wall-slab structures were peformed. For the purpose of this study slab-wall substructures of an apartment building were chosen. And two specimens with different aid ratios have been tested. There were subjected to reserved cyclic loading, consistent with coupling action, with increasing imposed inelastic deformations. From. the result of this test, 1) in slabs, the coupling stress are not uniform across the width, 2) cracks are tending to be concentrated in the regions near the inner edges of the walls, 3) the effective width used in previous theoretical or model studies may not be enough.
-
Fiber Bragg Grating sensors currently attract a great deal of attentions, mainly due to their potentials in health monitoring for civil structures and composite materials. In this experimental study, the strains of reinforced concrete beams were measured to failure In order to verify the applicability of FBG(Fiber Bragg Grating) sensors. The FBG sensors were directly buried in concrete and attached to re-bars at the time of fabrication. In this experiment, the changes of strains in concrete and re-bars were successfully measured as the movement in wavelength of light signals. The FBG sensors may be a very effective tool to investigate the behavior inside of reinforced concrete structures.
-
Lateral confining effect due to the existence of the shear reinforcements in R.C. beam is investigate in a numerical way. For the purpose, a three dimensional constitutive model of concrete is developed based on the elasto-plasticity using non-associated plastic flow rule to control the excessive inelastic dilatancy. The plastic flow direction is determined based on the associated plastic flow direction in a way to adjust the directional angle between the two normal vector components along the hydrostatic and deviatoric axis in a meridian plane in which the loading function prescribed. The current formulation is combined with the four parameter elasto-plastic triaxial concrete model recently developed. The resulting elasto-plastic triaxial concrete model predicts the fundamental behaviors of concrete under different confining levels and the 4-points flexural test of a beam with shear reinforcements, compares with the experimental results.
-
Recently, there have been increased much concerns about repair and rehabilitation works for aged concrete structures. In particular, it is known that due to repeated overburden vehicle there are significantly increasing number of aged concrete bridge slabs, which are strongly needed to construct and rehabilitate by innovative construction method. The objective of this research is to develop the new construction method of concrete slab in bridge structure, which can contribute to minimize the traffic congestion during the repair and rehabilitation works of aged concrete slab, and can also sufficiently assure the quality through the minimization of in-situ works at the site. I-beams with punch holes, which are substituted instead of main reinforcing steels in concrete slabs, will be manufactured in accordance with the specification in the factory. and will be preassembled into the Panel. After erecting the preassembled panels in the site, concrete will be poured into the slab panel. This research is to investigate physical properties of I-Beam with punch holes itself through static and fatigue test with rational numerical analysis Finally this research is to suggest reformed I-beam through the numerical analysis.
-
This paper presents a bond characteristics of high strength steel reinforced concrete members. High strength steel is what yield strength is higher than that of normal strength steel. So, the amount of flexural steel needed in R.C. members can be decreased. In result, it is expected that the workability and structure quality can improve and man power can minimize. For this purpose, specimens were made and tested with experimental parameters, such as concrete strength, steel diameter and yield strength. The result showed that under same tensile force of steel, in case of substituting normal strength steel with high strength steel, maximum bond stress increased and development length didn't almost change. In addition, the governing equation of bond and bond stress verse slip relationship were derived and compared with test values such as maximum bond stress, slip and bond stiffness.
-
The algorithm and program which implement the bond-slip behavior of pre-tensioned concrete beams to the nonlinear strut-tie model approach, are developed in this study. The validity of the algorithm and program is verified through the strut-tie model evaluation of the strength and behavior of two pre-tensioned concrete deep beams which were failed by bond-slip.
-
Generally, the contribution of curbs and median strip is not considered carefully in analysing and designing the girder bridges. There being curbs, the load given on interior girder relatively reduced and on exterior girder increased. Curbs and median strip reduce the load distribution factor by distributing the load given on girder fairly, In this paper, the Influence of curbs and median strip in wheel distribution through parameter study and lateral distribution test of PSC girder bridge was investigated. Finite-element analysis was performed with parameterizing the flexural rigidity of the girder, span length, girder spacing, median strip, curbs. The influence of curbs and median strip would increase with lowering rigidity of girder. In addition, curbs lower the load distribution factor of exterior and interior girders.
-
A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.
-
Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.
-
Mechanical properties of mortars and concretes blended with GCC(Ground Calcium Carbonate slurry) and silica fume were investigated. Results from this study showed that air contents of mortars were constant regardless of replacement of GCC and flow values of mortars were decreased with replacement of it. Especially, mortars and concretes replaced with 10% of GCC had a good trend with respect to compressive strength. In case of simultaneous use of GCC and silica fume, the workability and compressive strength of the concretes seem not to be any problems in mechanical properties. This study indicated that the most reasonable replacement of GCC was 10% and the addition as fine aggregate was more effective than that as binder.
-
Ground granulated blast-furnace slag shows very high strength when proper alkali-activator exists. This paper deals with setting time, heat evolution rate and the strength development of alkali-activated slag cement activated by KOH, Ca(OH
$)_{2}$ ,$Na_{2}$ $So_{4}$ , and alum(potassium aluminum sulfate). Alkali-activated slag mortar is studied by comparison with GGBF slag cement mortar. The experimental results indicate that for moisture curing at$25^{\circ}C$ , the addiction of either 4%$Na_{2}$ $So_{4}$ or 4% alum increases the strength of GGBF slag cement mortar consisting of 50% GGBF slag and 50% portland cement at early age. Strength of activated GGBF slag cement mortars at 1, 3 and 7 days exceeded that of GGBF slag cement mortar. A conduction calorimeter was used to monitor early age hydration. -
Several studies have reported that Granulated Blast-Furnace Slag improved the properties of concrete. The Granulated Blast-Furnace Slag could be a good alternative in the shortage of aggregate situation. Slag shows the possibility of influential aggregate and effect of environment preservation. This study presents that the basic properties of fresh concrete using Air-cooled Blast-furnace slag aggregate and Water-cooled Blast-furnace slag aggregate. Testing Factors of this study are concrete slump, slump loss, bleeding, and air contents. The result of this study is below. 1) In case of proportion slag and grave is 50 to 50, the biggest slump value is measured. 2) In the concrete using of air-cooled Blast-furnace slag aggregate, the bleeding capacity is a little. In the concrete using of Water-cooled Blast-furnace slag aggregate, the bleeding capacity goes up to 50% increase. 3) As substitution rate of the granulated blast-furnace slag goes up, air content is increased.
-
In this study, it was analized and examined fundamental properties of Electric Pole Recycled Aggregate(EPRA) and hardened properties & chemical resistance with H
$_2$ SO$_4$ by replacement ratios of EPRA, and the results are as follows 1) In the case of electric pole recycled coarse aggregate, All fundamental properties are better than that of normal recycled aggregate and both water absorption and amount of crushed loss are with level of natural aggregate 2) As the replacement ratio of electric pole recycled fine aggregate is increased strength development is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate 3) As the replacement ratio of electric pole recycled fine aggregate is increased chemical resistance is decreased. but in the case of coarse aggregate, that of it is with level of natural aggregate -
An experimental study was carried out to investigate recycling of an oyster shell, which is disposed in open-dumped way at coastal oyster factory area. For this purpose, the chemical component and reaction of oyster shell with cement paste was examined. And, the characteristics of hardened concrete was quantitatively investigated in terms of fineness modulus and blending rate of the crushed oyster shell. Test results show that interaction between oyster shell and cement paste was not occurred and the crushed oyster shell can be used as the fine aggregate of concrete. And it is found that blending of an oyster shell caused not to reduce the 28 day compressive strength of concrete. Elastic modulus of the concrete blended with crushed oyster shells decreases with increases the blending rate which the modulus reduced about 10% when oyster shells is blended up to the 20% of the sand substitution.
-
An investigation into using Oyster Shells partially or wholly as aggregate in concrete is reported. The proportion of shells was varied with ratios of 10, 30, 50 and 100% by volume of fine and coarse aggregate. Two water/cement ratios of 0.45, 0.55 were considered and air-entraining superplasticizer was used to improve concrete workability Two strength properties (compressive and flexural) were considered. Strength tests were carried out at the ages of 1, 3, 7, 14 and 28 days. The variations of workability, weight and density of the specimens with different proportions of Oyster Shells were also studied. Results showed that compressive and flexural strengths decreased with increase in proportion of Oyster Shells to aggregate in the reference mixes. The workability of concrete batches decreased with increase in the proportion of Oyster Shells in the mixes. The same trend was observed with density and weight of the specimens
-
Mass concrete is placed considering placing lifts in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.
-
Box-culvert is very important structure used almost every road construction. However this is treated very simple structure in design and construction. So many crack such as nonstructural crack has been occurred. This crack is very harmful on durability of concrete. In this study, thermal crack, one of the nonstructural crack, of box-culvert controled by using rapid-strength belite cement concrete. In this process, not only heat of hydration and thermal stress but also material mechanics properties and characteristics of durability were tested. and same model box-culvert using OPC concrete is constructed in same condition for comparison.
-
The crack of concrete induced by a temperature rise in early age concrete due to the heat of ration of cement is a serious problem for massive or high strength concrete structures. However, re is still no reasonable equations for the prediction of the temperature rising. On this study, the prediction equations of the heat of hydration of different types of binder are pained from the adiabatic temperature rise test, and compared with the results from different nations to obtain the best approximated equation. The strengths of concrete of which specimens were placed in the same chamber for the adiabatic to were compared with those under standard curing.
-
This study was peformed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a results, the optimal mixing conditions were : W/B 41%, unit binder 375kg/
$cm^{2}$ , FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$cm^{2}$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps. -
Experimental programs were accomplished to improve and evaluate the structural performance of test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation of and ductility etc. Test variables are restraining factors of frame, with or without masonry infilled wall, and masonry method Six reinforced concrete rigid frame and masonry infilled wall were tested and constructed in one-third scale size under vertical and cyclic loads simultaneously. Based on the test results, the following conclusions can be made. For masonry infilled wall with restraining factors of frame, maximum horizontal capacities were increased by 1.91~2.24 times in comparision with that of rigid frame. For masonry infilled wall with restraining factors of frame(IFWB-l~3), cumulated energy dissipation capacities wear increased by 1.35~l.60 times in comparision with that of masonry infilled wall(IFB-1) at final stage of testing.
-
This research was conducted to investigate the seismic behavior and capacity assessment of circular spiral reinforcement concrete bridge piers used in high strength concrete. The displacement ductility, response modification factor(R), effective stiffness and plastic hinge region etc. was used to assess the seismic behavior and capacity of circular spiral reinforcement concrete bridge piers. The experimental variables of bridge piers test consisted of amount and spacing, different axial load levels. From the quasi-static tests on 9 bridge piers and analysis, it is found that current seismic design code specification of transverse confinement steel requirements and details may be revised.
-
Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seismic performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.
-
The objective of this experimental research is to assess the seismic performance of circular RC bridge pier specimens retrofitted with fibers which were designed as a prototype of Hagal bridge in the city of Suwon, Korea. Pseudo-dynamic test has been done for two nonseismic test specimens which were nonseismic designed by the related provisions of the Highway Design Specification, and four nonseismic test specimens retrofitted with fibers in the plastic hinge region. Important test parameters were load patterns, and retrofit. The seismic behavior has been analyzed through the displacement ductility, energy analysis, and capacity spectrum. Approximate 7.0 displacement ductility was observed for nonseismic test specimens retrofitted with fibers. It is concluded that these retrofitting test specimens could have sufficient seismic capacity in the region of moderate seismic zone.
-
Base shear and roof drift relation was acquired from experiment of 3 story ordinary moment resisting frame which was designed using gravity loads. To evaluate the dynamic behavior of the frame, analytical model was generated from experimental result. Dynamic analysis was performed using the analytical model subjected to earthquake ground motions with 500, 1000, and 2400 years of return period. And capacity spectrum method was adopted to find the performance points of the frame. Both dynamic analysis and CSM showed that the performance of the frame meet the life safety objectives suggested by FEMA 273 and ATC 40.
-
The objective of this study is to assess seismic damage potential and evaluate structural performance of columns in concrete moment frames. For this purpose the results of 3 former studies are compared. Experimental variables considered in these studies are lap-splice of longitudinal reinforcement, axial load level, longitudinal reinforcement ratio, etc. The columns in 1st story of the building are considered in these studies since the columns in 1st story shall resist largest axial force during an earthquake. Based on test results strength, ductility capacities as well as plastic hinge length are compared and discussed.
-
A method is described for predicting crack with and spacing in Steel Fiber Reinforced Concrete (SFRC). The crack behavior of SFRC influenced by longitudinal reinforcement ratio, volume and type of steel fiber, strength of concrete. It can be observed from experimental results that addition of steel fiber to reinforced concrete beam reduces crack width in serviceability limit states. The proposed method predicts crack widths in cracking stage of the beam. Calculated crack widths obtained for reinforced concrete beams and different volume and type of steel fiber, strength of concrete showed good agreement with experimental results.
-
Cracks in concrete can submit shear forces by virtue of the roughness of their interfaces. With regard to this roughness, the crack faces play an important role. By transmitting normal and shear stress across their faces, shear cracks contribute to shear resistance. This process is called shear transfer or more generally, shear friction. Both experimental and analytical program to investigate shear transfer mechanism in normal and high strength concrete were included in this study. The parameters investigated in push-off test included the concrete strength, the presence and amounts of steel stirrups, and aggregate size. Solution procedure based on the truss model was developed to analyze the shear transfer behavior. In general, it can be seen that the analytical results agree well with results of shear transfer test.
-
Nine steel fiber reinforced high strength concrete beams and three steel fiber reinforced normal strength concrete beams without stirrups were tested by two point load. The variables studied in this investigation are the shear span/depth ratios of a/d = 2, 3 and 4, steel fiber volume fractions of
V$_{f}$ : 0, 0.5% and 0.75% and concrete compressive strengths off$_{ck}$ : 630kgf/$cm^{2}$ , and 310kgf/$cm^{2}$ . Based on these tests and on tests by previous investigators, predictive equation is proposed for evaluating the ultimate shear strength of steel fiber reinforced concrete beams without stirrups. The proposed equation gave good prediction for the ultimate shear strength of the tested beams. -
Most of the predicted shear strength of continuous R.C. beam whitout web reinforcement were accepted by testing simple beams. But the experimental results may show that a differential behavior on simple and continuous R.C. beam. In this study, estimated shear strength of continuous R.C. beam without web reinforcement with internal force state factors by test as purpose to apply available predicted equation to normal continuous R.C. beam. This equation is applied to experimentally tested data and the results were compared with those predicted by the codes. Predicted shear strength using force state factor can provide a tested data rather than codes which like ACI
-
In these days, high-strength steel prevails throughout the construction fields for the benefit of structural and economical aspects. But high-strength steel is used by the simple calculation of flexural capacities for the purpose of reducing flexural reinforcement. So, this paper is mainly focused on the shear behavior of high-strength steel reinforced concrete beams without stirrups comparing with normal-strength steel reinforced concrete beams. Specimens were made and tested with the experimental parameters, such as steel yield strength, reinforcement ratios and minimum shear reinforcement. The main result was that not only area but also the yield strength of flexural reinforcement should be considered to predict the shear capacities of concrete beams.
-
This paper is to explain reasonable shear behavior that can apply usually to reinforced concrete beams on the basic concepts of existent analysis and experimental research information. This study is succession
$paper^{2) 3) 4) 5)}$ of treatise announced in existing and main control variable of reinforced concrete beams with stirrups used internal force state factor($\alpha$ ). Shear failure of reinforced concrete beams with stirrups is Influenced greatly because of the actual geometrical shape(a/d) of the concrete and flexural reinforcement steel ratio, stirrup reinforcement ratio and concrete compression strength, size effect etc. Therefore, shear behavior of reinforced concrete beams with stirrups that flexural crack is happened can be explained easily through proper extent proposal of internal force state factor($\alpha$ ) that express internal force state flowing. Use existent variable truss model by analysis model to explain arch action. Also, wish to compose each failure factors and correlation with internal force state factor by function, and when diagonal cracks happens, internal force state factor($\alpha$ ) study whether shear stress and some effect are. -
This paper presents the effectiveness of cold weather concreting by applying both anti-freeze agent and insulating forms developed through previous study investigating insulating effects on the concrete and the strength gain. According to test results, in
$-10^{\circ}C$ of air temperature, when euroforms are applied, the temperature of plain concrete drops below$0^{\circ}C$ and maintains its temperature during early 24 hours. However, when insulating forms are applied, the temperature of concrete keeps 8~$13^{\circ}C$ during first 24 hours. Insulating forms has better performance on insulating effects than existing euroforms. Concrete containing anti-freeze agent shows temperature rising effects about$1^{\circ}C$ compared to plain concrete. Strength gain of core concrete shows higher when insulating forms is applied. -
The purpose of this study is to analyze representative methods of concrete mix design. As a results, it can be said that the properties of concrete are studied primarily for the purpose of selection of appropriate mix ingredients, and it is in this light that the various properties of concrete will be considered in appropriate mix design method.
-
This study is to characterize the material property of early age high performance concrete emphasizing compressive strength using nondestructive testing methods. Three high performance concrete slabs of 600, 850 and 1100kg/
$cm^{2}$ compressive strengths were prepared together with cylinders from same batches. Cylinder tests were peformed at the ages of 7, 14, 21 and 28 days after pouring. Using the impact echo method, the compression wave velocities were obtained based on different high performance concrete ages and compressive strengths. The equation to obtain the compressive strengths of high performance concrete has been developed using the obtained compression wave velocities. Using the SASW (spectral analysis of surface wave) method, the equation have also been developed to obtain the compressive strengths of high performance concrete based on the surface wave velocities. -
Recently, it has been processed to study about recycled aggregate but a study about using of recycled powder is producted when manufacturing recycled aggregate has not been acted. So in this study on the fundamental properties and application as cementious admixture by heating temperature for mortar properties of recycled powder and sand is obtained like following results. It is judged that application of recycled powder of heat treatment on
$600^{\circ}C$ and cement replacement ratio below 10% is available. -
Generally, when Fly-Ash was used as replacement material of cement in concrete, it might occur retardation of setting and hardening. So, it is unable to use a large amount of Fly-Ash as replacement for cement. However, if it is used as replacement material of fine aggregate in concrete, we can use a large amount of Fly-Ash and settle a problem of natural-aggregate exhaustion. Furthermore, engineering properties of High Volume Fly-Ash Concrete Is better than that of plain concrete But, the larger Fly-Ash is replaced, the more fluidity of High Volume Fly-Ash Concrete decrease, because porous organization of Fly-Ash adsorb water and Superplasticizer. In this study, after appending additional water to High Volume Fly-Ash Concrete in proportion to weight of Fly-Ash, we intend to find proper ratio which doesn't affect strength and satisfy fluidity As a result of this study, it was found that fluidity of mortar with 25~28 percentage of additional water was satisfied with fluidity of plain mortar, and compressive strength of that was similar to plain mortar's
-
The purpose of this study was the influence of cold weather ready mixed concrete quality according to needs of customer were investigated by measurements of slump, air content, temperature and compressive strength. As a results, cold weather ready mixed concrete using high standard admixtures, high early strength admixtures and cold weather concrete plant were similarly to slump, air content, temperature and compressive strength.
-
Recent long-span bridges, such as Kwang-Ahn Grand bridge, Seo-Hae Grand Bridge, Young-Jong Grand Bridge, etc, have been designed and constructed near the shore. Thus, it needs to analyze the durability of marine concrete structures which are exposed to severe chloride environments. It is well known that corrosion of reinforcement steel in concrete is one of the major factors for the durability of concrete structures. The objective of this experimental study is to investigate the performance of impressed current system and corrosion inhibitors for the corrosion protection of reinforced concrete structures. Concrete test specimens were made with various test parameters, such as cover depth, steel diameter, compressive strength, direction and frequency of notch. For the efficient evaluation of these corrosion protection systems, these tests have been carried out in the shore.
-
This paper was studied to effects of fatigue by low flexural load on micro structures and carbonation of mortar. Mortar specimens cured at various conditions were first subjected to bending repeated loads, and it was made clear that insufficient cure reduced fatigue resistance of them. Next, fatigue tests that the stress levels are lower than the ones of fatigue rupture were carried out, The effect of curing conditions in early age on carbonation was furthermore studied using the scale, and it was made clear that insufficient cure is also susceptible to carbonation of them. Finally, the reason for rapid carbonation of fatigued mortars insufficiently outed was discussed from the view point of changes in pore structure of them.
-
The studies on chloride diffusion of concrete have been done so far by many researchers. However, there are few studies that present the effects of other attacks on chloride diffusion properties. Therefore, in this study the experiments are carried out to show the effects of combined attacks, such as carbonation, sulfate attacks, on chloride diffusivity in concrete. The specimens are made by varying cement type and replacement ratio of fly ash. The results show that cement type and replacement of fly ash do not affect greatly chloride diffusion properties. And concrete treated by combined attacks show a little higher chloride content than those treated by chloride solution only. Therefore, the effects of these factors should be taken into account in predicting the penetration of chloride ion in concrete.
-
Reinforcement corrosion is major problem for those who own and maintain reinforced concrete structures exposed to chlorides. It is well understood that the form of corrosion is more problematic than corrosion found elsewhere, Because concrete has no apparent signs that there is anything amiss until the process of deterioration is relatively far advanced. The objective of this research is to develop the ladder system which monitors the corrosion of reinforcing steels in concrete. This system can be used to assess the corrosion condition and corrosion rate of steel in concrete, which can give timely repair and strengthening of steel in concrete structure.
-
In this study, a method to evaluate diffusion coefficient of chloride ion in cracked concrete is proposed. For cracked concrete having either anisotropic or isotropic crack network, each crack of saturated concrete is considered as a V shape crack, and an effective diffusion coefficient is expressed with diffusion coefficients of cracked part and noncracked part and a so-called crack spacing factor. A comparison with experimental results shows that the diffusion coefficient for cracked concrete is accurately predicted by the effective diffusion coefficient. Prediction results also show that the cracks in concrete markedly change the diffusion properties and accelerate penetration of drifting species. The method in this paper can be effectively used to consider the effect of cracks on concrete diffusion coefficient of cracked concrete.
-
In case of constructing the concrete structures under seawater environment, the concrete suffers from deterioration due to penetration of various ions such as chloride, sulfate and magnesium in seawater. Tn the present study, Immersion tests with artificial seawater were carried out to investigate the resistance to seawater attack of antiwashout underwater concrete. From the results of compressive strength, it was found that blended cement concrete due to mineral admixtures such as fly ash(FA) and ground granulated blast-furnace slag(SGC), were superior to ordinary portland cement concrete with respect to the resistance to seawater attack. Moreover, XRD analysis indicated that the formed reactants of ordinary portland cement paste by sulfate and magnesium ions led to the deterioration of concrete. As expected, however, the blended cements with FA or SGC have a good resistance to seawater attack. This paper would discuss the mechanism of seawater deterioration and benefical effects of antiwashout underwater concretes with mineral admixtures.
-
Recent trends in the construction of long span or tall building frames feature the increase use of composite members that steel and concrete is functioning together in what terms of mixed structural systems. One of such systems, RCS (reinforced concrete column and steel beam) system is introduced and closely examined focusing on bearing strength of the composite joint in this paper. The main objective of this study was to develope detail to increase bearing capacity while bearing failure is one of the two primary modes of failure in RCS system. The results show that specimens with the U-type bearing reinforcement detail developed in this study enhanced the bearing strength by 1.20-1.50. The U-type reinforcement is the effective details to increase joint bearing strength compared to others like vertical reinforcement welded to beam flanges.
-
Waterproofing materials should be expected to last the life of the structure. An approximate life cycle cost should be to compare different materials based on initial and periodic repair / maintenance costs. Waterproofing applicators like materials that are easy to set up and clean up. The designer should choose a material that can be applied in almost all conditions. Design Professionals should specify independent inspection on critical jobs or in all cases where the budget permits. The basic causes of defection occurred during construction should be minimized.
-
This paper presents the fundamental study on rational manu(acture of Very High Strength(VHS) concrete using industrial by-products as like silica fume, slag and fly ash. In this study, we had tested various mixing cases to manufacture the VHS concrete(target compressive strength : over 1,000 kgf/
$cm^{2}$ ) which is easily workable (target slump flow : 60$\pm$ l0cm), The main variables studied are; 1) test variables to find the optimum replacement ratio of mineral admixture, 2) test variables to find a rational water-binder ratio, a proper binder content, 3) test variables to find the method for reduction of slump loss, 4) test variables to know the influence of air entrainment on frost resistance. From the test results, it is concluded that the rational mix design can be made by using 40% slag, 10% silica fume, and water reducing agent(slump loss reduction type). We found that it is unnecessary to entrain air for freeze-thawing resistance. -
The main purpose of this study is to evaluate early age thermal stresses and to estimate the risk of thermal cracking in the footings of Hyungsan bridge. In this study, stress analyses are performed for several construction stages using the computation of temperature distributions. The stress analysis results show that, not using the embedded pipe cooling, placing the concrete at once for each footings may cause sever thermal cracking. So, the structures should be constructed with one horizontal construction joint. Then the height of each lifts were determined to be 1.50 meters. Using various time intervals between lifts, temperature and stress.
-
Mass concrete of reaction structure was investigated to minimize cracks generated by the heat of hydration. Suggestions are noted in this paper through the experiences of planning, technical study, computational analysis and field instrumentation.
-
In this thesis, the study on controlling of cracks of concrete box culvert in early ages is presented. The optimum construction method and economical analysis were proposed also through the experiment of the material and field test. As a result of the experiment of the material, using fly ash, CSA expansive agent and BELITE cement(type IV) showed good result in the control of cracks induced by heat of hydration and shrinkage. As a result of construction test analysis, the maintenance time of form system did not show a big difference in controlling of cracks. Control of distribution of reinforcement, spacing of expansion joint and use of BELITE cement showed big differences in the control of cracks in early ages. As a result of economical analysis, control of construction variables before construction can make it possible to reduce the repair expense.
-
In this study, experimental research was carried out to develop protective finishing, coating materials and new hybrid technique for deteriorating prevention and high durability in concrete structures. It had sufficiently recommended performance for the protective finishing method of concrete structures through testings. This is more progressive double membrane method than single membrane type designed by conventional method. It was found that this hybrid construction method had very excellent performance to improve the durability of existing concrete structures and attain the beauty of concrete structures.
-
This study is about application to real construction site of estimating a early strength with use of microwave. Based on the exist studies, it is tried to confirm the correlation between curing temperature and estimating early strength method with microwave. The result of this study are as follows. 1) Coefficient figure of common use concrete's accelerating strength and 28 days strength after curing at
$10^{\cire}C$ ,$20^{\cire}C$ ,$30^{\cire}C$ is 0.84, 0.80, 0.80 2) Coefficient figure of concrete's-has a low fine aggregate ratio- accelerating strength and 28 days strength after curing at$10^{\cire}C$ ,$20^{\cire}C$ ,$30^{\cire}C$ is 0.86, 0.82, 0.81 -
Permanent-Form is one of system forms for reducing human labor, work costs, oscillation, noise, construction wastes and so on. Permanent-Form is made from precast method in facilities. and carried in construction site to assemble with no demolding. The biggest expense to produce Permanent-Form is about manufacturing mold. To satisfy various size of building member, the same number of manufacturing mold is needed. In this paper, studied about manufacturing mold module for acquiring economic merit and construction member safety. Permanent-Form is member stress and structural analyzed if temporary equipment were used. The result of this study is below. (1) Column sizes of Permanent-Form are 47 kinds of prototype that based on Modular coordination's basic module. 4 pieces or 6 pieces are composed basically. (2) For beam size modular coordination, standard height and width of beam are 150mm and 100mm. It brings 24 kinds of prototype. 4 pieces or 5 pieces are composed basically. (3) Structural analysis value of modular member is like this Column member shows 9.4 to 85kgf/
$cm^{2}$ stress distribution and beam member shows 6.3 to 95kgf/$cm^{2}$ stress distribution. Constructing permanent form could have structural safety with use of temporary equipment -
CFT concrete has high flowing, high strength and resistance to material separation to use skyscraper structure. It is considered that concrete could fill the lower part of Diaphragm up. This kinds of CFT concrete hardly apply to building below 20 stories. Using the common use strength concrete to building below 20 stories brings to reduce construction cost. This concrete is needed that valid fluidity and packing ability with unit cement content as common use strength concrete. Offering a fundamental data and proportioning in CFT concrete of below 20 stories, it is executed basic property test, analysis of proportioning and mock up test.
-
The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method. The result of study is below (1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in joint column. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.
-
The purpose of this study is to analyze the curing effect of heating cable for concreting in cold weather. An experiment was conducted to evaluate the temperature history of concrete structures cured with embedded heating cables. Results are as follows : In comparison with the non-heating case, applying of heating cable resulted in the rise of temperature in the range of
$10^{\circ}C$ . In order to get successful results, the optimal pitch length for the embedded heating cables ranged from 20cm to 25cm. When working with the existing curing methods, applying this heating cable would be more effective in concrete curing. Finally, a formula and process was suggested to predict the Internal temperature history of concrete structures under the various curing conditions. -
Occurrence of crack in the Half-loc of rubble mound breakwater under T.T.P (Tetrapod) can cause serious problems in structural safety. There, probing of such cracks in marine structures is an important process in evaluating the overall integrity of structures. Ultrasonic, SASW(Spectral-Analysis-of-Surface-Waves)and Impect-Echo methods were used for the inspection of pilot concrete and SFC (Steel Fiber Concrete) block in this study. The advantage and limitations of these methods for non-destructive inspection in concrete blocks are investigated. As a result, it has been verified that these methods proved to present effective solution for detecting the crack of the pilot concrete block.
-
Voids created with concrete construction or deterioration result in serious weakness from the aspects of both structural and durable function. Ultrasonic method using image processing technique was used for detecting pattern of voids in concrete in this study Experimental investigation was carried out for three types(patterns) of void in concrete. The effect of curing period of concrete and ultrasonic measurement method was also investigated. As a result it has been verified that the semi-direct measurement method is more effective than the other methods for detecting pattern of voids in concrete in ultrasonic method using image processing technique. The longer the curing period of concrete is, the better the detection accuracy of void pattern can be obtained.
-
The acoustic emission(AE) signal from concrete cylinder specimen during failure process under cycling compressive loads were recorded and analyzed. Different filters were set on the AE signal duration based on the characteristic of amplitude distribution. From the value of AE signal amplitude, which corresponds to the occurrence of the peak for AE hits, the AE signals from concrete compressive specimen were divided into five sections. The relationship between the AE signal section and the failure mechanism of these materials, analyzed on the meso-structure level was determined. Based on the experiments, the AE characteristics of each failure mechanism are given. The results show that the AE technique is a valuable tool to study the failure mechanism of concrete.
-
Two evaluation techniques of the tunnel lining concrete using ultra sonic velocity method are developed. Modified linear regression technique is proposed to enhance the corelation between the pulse velocity and the compressive strength of core specimens. And bivariate normal distribution is assumed to evaluate the quality of concrete as a terms of compressive strength. A simple corelation table between the pulse velocity and the compressive strength of core specimens are proposed.
-
In the latest, the construction period became the most important factor in the domestic building works because buildings is higher and larger gradually. Accordingly, cold-weathering concrete constructions are performed more and more. So, the demands of concrete quality management methods are increased in cold-weathering concrete constructions. In this study, the mock-up experiment was performed to correct input data in the kimpo H construction field. Using the results of this experiment, the method of temperature analysis was presented to prevent early aged freezing damage and to control thermal crack in this study.
-
This study is peformed for checking the limitation and application of each curing/heating methods on cold-weathering mat foundation construction, considering temperature control, early strength security and temperature declination range limit, by means of concrete material properties and thermal analysis technique that were published previously. In the result of this analysis, we checked the open air temperature and mat depth that are possible to apply each curing/heating methods on cold-weathering construction and found curing/heating time of each methods that is able to prevent early aged freezing damage and thermal crack
-
This paper provides an overview of the unreinforced masonry in Australian Standard, especially places the focus on a seismic code. Australia, like Korea, is a country of lower seismicity, and strengthens the code of unreinforced masonry since Newcastle earthquake of magnitude 5.6 in 1989. It is useful in establishing Korean code for unreinforced masonry to compare Australian Standard to Korean.
-
This paper presents four types of strut-tie model design approaches of structural concrete through the anchorage zone design of a post-tensioned concrete I-beam. The differences and distinctive feature of each approach in terms of structural type of selected strut-tie model, external force acting on strut-tie model, effective strength of concrete strut, and strut-tie model design procedure are analyzed and compared. The outcomes of present study enable structural designers to understand the merits and demerits of each strut-tie model design approach, and thus to conduct reasonable and accurate design of structural concrete.
-
A multi-level optimum design algorithm for prestressed concrete (PSC) box girders is proposed in this paper. To save the numerical efforts, a multi-level optimization technique using model coordination method that separately utilizes both tendon profile design and section design is incorporated. And also, a reduced basis technique for the efficient tendon profile optimization is proposed in this paper. From the numerical investigations, it may be positively stated that the optimum design of PSC box girder based on the new approach proposed in this study will lead to more rational and economical design compared with the currently available designs.
-
The objectives of this study are to investigate effective stiffness of circular reinforced bridge columns and to provide reasonable effective stiffness equations for seismic design to the current Korean Bridge Design Standard. The material nonlinear analysis was conducted for 5184 columns of which variables were the concrete compressive stress, the steel yielding stress, the longitudinal steel location parameter, the longitudinal steel ratio, the axial load level, and the diameter of section. The current Korean Bridge Design Standard generally used the gross section stiffness because of unclear provision, it may be non-conservative because of being evaluated greater design seismic force and less design displacement than those of the abroad provision. Therefore, the proposed effective stiffness equations include three variables such as : the longitudinal steel location parameter, the longitudinal steel ratio, and the axial load ratio. Two equations of effective stiffness are proposed which may be used for earthquake force estimation and for earthquake displacement estimation, respectively.
-
The length-depth ratio of the preflex and PSC girder is very important variable. But PSC girder is very difficult to reduce the depth. If the bridge that girder depth is most important variable, then generally the great part of engineers are use the preflex girder that more expensive method then PSC girder. This paper introduce the design example that replace the preflex girder with the IPC girder The bridge span is 44m, and depth is 1.15m. The depth is restrained in 1.15m by several conditions. And it is compare preflex with IPC girder in semi condition. These two girders are very different in economy and execution. So, this paper present more economic and easy construction method.
-
The primary objective of this study is to develop the new equation that can predict the flexural strength of irregular walls by applying the concept of the effective width which is used in current codes. Results obtained from this data analysis are as follows : 1. It is conservative to use PCI provision and ACI code as the effective width for evaluating the flexural capacity of irregular walls 2. The result of this study shows that the Paulay & Priestley's proposition is available for more exactly and safely predicting flexural capacity of irregular walls throughout a reduction factor.
-
Experimental studies were peformed to investigate variations in ductility of shear wall with length of boundary confinement. Eight specimens containg different lengths of confinment zone, which model compressive zone in plastic regions of shear walls, were tested against eccentric vetical load. Stress-strain model for confined concrete was used to predict strength and ductility of the specimens, which was compared to the test results. The results obtained show that failure of the compressive zone occurs in a brittle manner when the stress of unconfined zone softened after the ultimate strength were reached. To enhance the ductility of shear walls with concentrated confinement zone such as barbell-type walls, the ultimate strength of the confinement zone needs to be increased, and for shear walls with distributed confinement zone the length of the confinement zone needs to be extended.
-
For earthquake resistance design, a response modification factor is used to reduce the design strength and it reflects ductility, reserve strength, redundancy and damping effect. But this factor has not theoretical basis. In this study, two response modification factors are compared and analyzed for shear wall apartment building.; the one is introduced by ATC-19 Procedures, the other is suggested FEMA-273 and ATC-40 through nonlinear static analysis. For the results, ATC-19 procedure gives a reasonable estimation to R factor. But
$R_{u}$ by using FEAM-273 and ATC-40 methods is estimated so small in case of a minor or moderate earthquake region. Due to this fact, response modification factor is smaller than suggested load criterion 3.0. So, it needs to decrease wall volume and reduce the global strength and system stiffness for proper ductile behavior matching to domestic load criterion. -
This paper propose a new seismic detail for ductility enhancement by interlocking spiral reinforcement in the potential yield regions of a wall. Through the theoretical consideration and experiment program, confinement with interlocking spirals lead the structural walls to ductile behavior. All specimens show stable hysteretic behavior and good energy dissipation capacity. Also the increase of shear strength mainly induces a flexural failure mode. As interlocking spiral are used in lapped splice region, they increase the bond strength and prevent a early tensile failure caused by the loss of bond stresses. Consequently, the confinement with interlocking spirals may result in a lower value of force reductions factor, newly proposed detail will be provide more economical design.
-
Recent earthquakes in California and Japan caused extensive damage to highway bridge structures. It is also thought that during probable earthquakes bridge structures in Korea could be failed due to the structural deficiencies, which were nonseismically designed and constructed before 1992. In these regards, innovative strengthening methods have been developed to repair reinforced concrete bridge columns, especially by glassfiber sheet bonding methods which are widely used today. The primary objective of this research is to investigate the seismic behavior of RC bridge columns retrofitted with composite straps and to propose pertinent guidelines of repair and rehabilitation method for earthquake resistant design procedure of RC bridges which are located in low or moderate seismicity regions. Six scaled-down concrete test specimens were made with test variables such as lap splice ratio, axial force ratio, confinement ratio, composite straps in the plastic hinge region. Pertinent design guidelines could be developed for the earthquake resistant design of RC bridge piers retrofitted with glassfibers in low or moderate seismic region.
-
Lap splice in plastic hinge region of RC bridge piers is inevitable because of the constructional joint between footing and column. RC circular columns with lap-splice in plastic hinge region are widely used in Korean highway bridges. It is, however, believed that there are not many experimental research works for nonlinear behavior of these columns subjected to earthquake motions. This study has been performed to verify the effect of axial force, lap splice and confinement steel ratio for the seismic behaviour of reinforced concrete bridge piers. Quasi-static test have been done to investigate the physical seismic performance of RC bridge piers, such as displacement ductility and enemy absorption.
-
In Korea, countermeasures against earthquake disasters such as the seismic performance evaluation and/or retrofit scheme of buildings have not been fully performed since Korea had not been experienced many destructive earthquakes in the past. The main objective of this paper is to propose the basic seismic protection index (Es) suitable to Korean buildings based on the seismic evaluation of existing reinforced concrete buildings using modified strength index. This paper will focus on 1) the selection of weak and moderate earthquake waves representing Korean seismic zone, 2) the creation of the required strength ratio spectra by seismic response analysis, and 3) the proposition of the basic seismic protection index (Es) suitable to Korean seismic activity based on required strength ratio spectra
-
The determination of compressive zone at the critical section of concrete walls under in-plane flexure is important in both assessing the ductility and designing the seismic retrofit. Recognizing this, the once-predominated code approach to determine the compressive zone was advanced by considering concrete rectangular stress block parameters varying with the extreme fiber strain in compression. It is shown that the major factors influencing the magnitude of compressive zone are axial load ratio, concrete strength, longitudinal steel ratio, yield strength and the level of strain at extreme compression fiber of wall sections. The present paper closes with the discussion for the research agenda requiring further study to investigate the behavior of reinforced concrete walls.
-
Recently, structure performance is maximized by using high strength concrete. In design of structure, concrete need combination with reinforcement, but use of common strength reinforcement make member complex bar placement, so high strength concrete members require increased strength reinforcement. If common strength reinforcement replaced by equal tension area of high strength reinforcement, reinforcement ratio increase and brittle failure of member may occur by material change. So, adequate upper limit of strength ratio is required to affirm ductile behavior in application of high strength reinforcement. In this study, ductility behavior was analysed by factor of reinforcement ratio, strength of concrete and reinforcement. The result indicate that ductile failure is shown under 0.35
$\rho_{b}$ in any reinforcement strength of same section and high strength concrete of 800kg/$cm^{2}$ used commonly is compatible with reinforcement of 5500kg/$cm^{2}$ . -
This paper deals with the estimation of the maximum flexural crack widths using minimum crack spacing for reinforced concrete members. The proposed method utilizes the conventional crack and bond-slip theories as well as bonding transfer length and effects of creep and shrinkage between the reinforcement and concrete. An analytical equation for the estimation of the maximum flexural crack width is formulated as a function of mean bond stress. The validity, accuracy and efficiency of the proposed method are established by comparing the analytical results with the experimental data and the major code specifications (e.g., ACI, CEB-FIP Model code, Eurocode 2, etc.). The analytical results of analysis presented in this paper indicate that the proposed method can be effectively estimated the maximum flexural crack width of the reinforced concrete members.
-
It is important to consider an effect of concrete member sizes when estimating the ACI rectangular stress block of a reinforced concrete flexural member. However, the experimental data and analytical analyses are still not available for a proper evaluation. For all types of loading conditions, the trend is that the size of an ACI rectangular stress block tends to change when the member sizes change. In this paper, the size variations of strength coefficients for ACI rectangular stress block and actual stress distribution have been studied. Results of a series of C-shaped specimens subjected to axial compressive load and bending moment were adopted from references 1 and 2. The analysis results show that the effect of specimen sizes on strength coefficients for ACI rectangular stress block and actual stress distribution of concrete member was apparent. Thus, the results suggest that the current strength criteria based design practice should be reviewed.
-
This study was conducted to analysis the distribution of the rectangular stress block for high-strength polymer concrete beam. C-shaped specimens were produced and tested to compute parameters of the rectangular stress block. They were
$\kappa_{1}$ = 0.73,$\kappa_{3}$ = 0.94 and$\gamma$ = 0.845, respectively. Experimental value of flexural strength of beam was same to be compared with theoretical value. But there is desirable to need many experimental data in order to exact design of polymer concrete structure. -
In this paper the biaxial failure criteria and stress-strain response for plain concrete are studied under uniaxial and biaxial stress(compression-compression, compression-tension, and tension-tension combined stress). The concrete specimens of a square plate type are used for uniaxial and biaxial loading. The experimental data indicate that the strength of concrete under biaxial compression, f2/fl=-l/-1, is 17 percent larger than under uniaxial compression and the poisson's ratio of concrete is 0.1745. On the base of the results, a biaxial failure envelope for plain concrete that the uniaxial strength is 398kgf/
$cm^{2}$ are developed. The biaxial failure behaviors for three biaxial loading areas are also plotted respectively. In addition, the characteristics of stress-strain response under biaxial compression are compared and verified with the experimental and analytical results. -
This study aimed to examine the cause of latent hydraulic property manifestation of ground granulated blast-furnace slag(GGBFS) using different alkali activators in pH, type and quantity. According to the experimental result, the higher pH value accelerated lastly latent hydraulic property and the early stage strength of GCBFS was ranked as activators with the higher pH, in an order of NaOH,
$Ca(OH)_{2}$ and$Na_{2}$ $Co_{3}$ . Also, NaOH had accelerated latent hydraulic property of GGBFS, which had 40~50% of the 3 and 7 days compressive strength of base mortar in case of using 10% of powder-weight. In the case of 30% of GGBFS substitution with annexing 2.5%$Ca(OH)_{2}$ , the compressive strength on the 3 and 7 days of the early-age, was increased to 5~10% than that of the same admixture with no activator. With annexing 5.0%$Ca(OH)_{2}$ , the strength was increased to 10~20%. Although activator NaOH was effective on the manifestation of latent hydraulic property, it caused cement mortar compressive strength decrease by enlarging pore diameter. -
This study search for absorbing sound and exhaust-gas which aims to manufacture continuous void by using clay and foam, the surface of materials is covered with
$TiO_{2}$ powder as heat treatment. According to the results of the experiment, the increase of thickness of manufactured sound absorbing materials caused the increase of absorption rate in the range of low and middle sound and thus it can be an important factor of improving absorption rate. Sound absorbing materials could satisfy 70% of the average of sound absorption ratio in 7cm thickness. Also, the manufactured sound absorbing materials is covered with$TiO_{2}$ showed an excellency in the clarification of exhaust-gas under ultraviolet rays treatment when 70% of removal rate and about 10% of generation rate of$NO_{2}$ is settled by the flow of 2$\ell$ /min NO gas. Especially, manufactured sound absorbing materials could improve compressive strength of continuos porous concrete. in the case of 7% bubble addition, when the substitution rate of coagulator was 30% and 20%, compressive strength was 45kgf/$cm^{2}$ and 65kgf/$cm^{2}$ respectively. As the substitution rate of coagulator reducing, compressive strength increased after preforming burnt clay. -
In this study, three kinds of fine aggregate (river sand, sea sand, crushed sand) were used and four different s/a (38%, 40%, 42%, 45%) were applied separately to this experimental for get the conclusion written below. Regardless of kinds of fine aggregate and casting-curing condition, maximum unit weight is seen at 40% of s/a and also to be seen in case of crushed sand. It's for that specific gravity of crushed sand is bigger comparatively than river sand and sea snad's one. Compressive strength is measured river sand, crushed sand, sea sand by order of size ; Regardless of variation of s/3, casting-curing condition and age. Compressive strength recorded maximum when s/a is 42% whatever sort of fine aggregate are. As the result, according to references, the optimum s/a of underwater antiwashout concrete is 40% but in this study, from compressive strength of view, the optimum s/a of underwater antiwashout concrete is 42%.
-
The prediction model is proposed to estimate the variation of compressive strength of fly ash concrete with aging. After analyzing the experimental result with the model, the regression results are presented according to fly ash replacement content and water/cement ratio. Based on the regression results, the influence of fly ash replacement content and water/cement ratio on apparent activation energy was investigated. According to the analysis, the model provides a good estimate of compressive strength development of fly ash concrete with aging. As the fly ash replacement content increases, the limiting relative compressive strength and initial apparent activation energy become greater. The concrete with water/cement ratio smaller than 0.40 shows that the limiting relative compressive strength and apparent activation energy are nearly constant according to water/cement ratio. But, the concrete with water/cement ratio greater than 0.40 has the increasing limiting relative compressive strength and apparent activation energy with increasing water/cement ratio.
-
The concrete which has placed under cold weather has some defects such as the decrease of initial strength by hydration delay, strength unrecover at unhardened concrete freezing and structural failure and crack by expansion pressure. So, in this study, we tried to develope the concrete which can be made under cold weather without defect by using of do-icing agency In concrete test, the used do-icing agency has the characteristics of de-icing and rapid hydration. By test results, Co{
$NH_{2}$ $]_{2}$ is unsuitable for workability, and NaN$O_{2}$ is the most suitable agency for cold weather. And for curing, the cured concrete at$21^{\circ}C$ for 24 hours has the safe strength. -
In general, Ti
$O_{2}$ photocatalysts have the strong oxidizing power under intense UV light irradiation. The strong oxidizing power of Ti$O_{2}$ photocatalysts are able to purify polluted air. Therefore, we intend to develop building materials with abosorbable and eliminatory NOx. In this study we used two types of Ti$O_{2}$ photocatalysts which are widely used as photocatalysts. As a result, we conclude that building material using Ti$O_{2}$ photocatalysts are able to purify polluted air. -
In this study, the characteristics of freezing and thawing resistance, the compressive strength, and the change in height of cement mortar according to steam curing methods has been studied. To this end, the major test variables include the period of the early curing, curing temperature and the later curing. The strength test as well as volume variousness have been conducted to explore the characteristics of thawing and thawing resistance on the curing methods. The experimental results in the present study can be efficiently used to improve the characteristics of freezing and thawing resistance for concrete products carrying steam curing.
-
In clod weather regions, a strong seasonal wind brings sea salts to the land. In addition to it, recently, the spreading amount of de-icing salts has increased numerously for the purpose of removing snow and ice. Thus the salts environment around concrete structures becomes so severe that various damages of concrete due to applied salts will be brought up. It is briskly carried out study on effects of do-icing salts on concrete in America, Japan, European countries. However, there are not test method for the deterioration of concrete subjected to both freezing-thawing and chloride attack in Korea. In this study, we conduct on test for the compound deterioration subjected to both freezing-thawing and chloride attack, in order to investigate effects of de-icing salts on the deterioration of concrete.
-
Poor water-proofing integrity is related to many factors : site procedure, workmanship, weather. substrate conditions, installation(including asphalt application) conditions. The evaluation of adhesive properties tested by concrete surface moisture and asphalt application was based on laboratory test and observations. This report describes the pull-off test results of waterproofing systems currently used for installing and reparing for concrete bridge decks. The test results showed that the moisture condition fully affected the adhesive properties of sheet membranes and sealer but partially for liquid membranes.
-
Chloride permeability of high strength concrete(HSC) was investigated using saltwater pending test and rapid chloride permeability test by electrical potential(ASTM C 1202). The lower water-cement ratio concrete showed the lower diffusion coefficient of chloride. The relationship between the diffusion coefficient of chloride and charge passed by the rapid chloride permeability test could be obtained. This relationship appears to be an effective method for evaluating chloride permeability of low water-cement HSC.
-
The long-term durability characteristics of high-early-strength concrete were assessed. The effect of long-term durability characteristics of high-early-strength concrete were investigated. In experiment, two different types of fiber were adopted for improvement of durability. High-early-strength fiber reinforced concretes using regulated-set cements are compared with high-early-strength concrete without fiber. The durability performance of the laboratory-cured high-early-strength concrete specimens was determined by conducting an accelerated chloride permeability, abrasion resistance, freeze-thaw, surface deicer salt scaling and wet-dry repetition test. The results indicated that incorporation of fibers enhance durability performance.
-
There are two types of chloride in concrete; one is added as concrete materials' chloride when concrete's mixing, and .the other is penetrated from the air and sea water in the sea-shore area. These chlorides penetrate into concrete, and they are accumulated inside the concrete with aging. This study aimed to evaluate the chloride ion penetration resistance of concrete containing GGBFS in the sea-shore area. Therefore, the specimens made with the replacement ratios(0, 0.30, 0.45, 0.60) of GGBFS were put into 3% NaCl solution according to the chloride accelerating test of JCI-SC3, and then investigated the weight changes, compressive strength, chloride ion with the depths of the specimens by aging. The result is that the diffusion coefficient of chloride ion is decreased with the increase of replacement ratios when compared to OPC
-
Recently, polymer-modified mortar has been studied for proposed use on industrial floors as top layers with thin thicknesses, typically 5~ 15mm. The purpose of this study is to evaluate basic properties of self leveling materials using polymer modifier as kinds of SBR, PAE, SUBA. Superplasticizer and thickener have been included in the mixes to reduce bleeding and drying shrinkage as well as in order to facilitate the workability required. The self leveling materials using four types of polymer dispersion are prepared with polymer-cement ratios which respectively range from 50%, 75%, and were tested for basic characteristics such as adhesion in tension, crack resistance test, rebound test after the preparative tests for unit weight, air content, consistency ratio etc. The results show almost as equal quality as existing commercial industrial flooring when mortar is modified by polymer dispersion. Adhesion in tension of polymer modified mortars using each SBR and PAE emulsion was over 10 kgf/
$cm^{2}$ . Crack or flaw derived from shrinkage is strongly dependent on the type of polymer dispersion because of each different total solid of polymer. It is judged that polymer modified mortar with self-leveling can be very well suited for Floor-finished. -
The purpose of this study is to find out the effect of polymer glass transition temperature on mechanical properties of polymer latex-modified mortars in comparison with ordinary cement mortar. The Polymer latex-modified mortars are prepared with 5, 10, 15 and 20% of polymer cement ratio respectively, and properties of modified mortars such as air content, compressive, flexural and tensile strengths are tested. The test results indicate that the types of polymer dispersion and the polymer-cement ratio are very important factors to characterize the properties of polymer-modified mortars, and also the glass transition temperature of polymer dispersions has an important effect on the performance of polymer-modified mortars. The modifying effects of two kinds of polymer dispersion, St/BA-1 and SBR, are evaluated.
-
The bend resistance of coated reinforcing bar is greatly influenced by adhesion strength of bar and coating materials and transformation of coating materials to the bar. Expecially, tearing state or a limited microscopic cracks are predicted on the inside and outside of bending angle because of adhesion strength and elongation is very different with types of polymer materials using bar coating, and these parts are accelerated corrosion as penetration of bar corrosion effects factor. In this study, cement modified polymer are prepared four types and differ from polymer cement ratio of 50% and 100%, coating thickness of 250
$\mu$ m and 450$\mu$ m, coating number, curing age of 3, 7, 14 and 280days, and then tested bend resistance as bending angle$90^{\circ}$ ,$135^{\circ}$ and$180^{\circ}$ for observe the microscopic demage effect according as bar bend. From the test results, when is used cement modified polymer as coating materials of bar, St/BA is showed excellent bend resistance than a polyacrylic emulsion and SBR because of softness. But it is to need attention because as coating parts are pressed down and tearing, also experimental study is proceeded to corrosion potential on the inside and outside of coated reinforcing bar. -
This study was conducted to develop a procedural method to produce a high strength polymer concrete using polyester resin to experimentally examine the stress block properties of the high strength polymer concrete. C-shaped specimens were Produced and test to compute parameter of the stress block. They were
$k_{1}$ : 0.73 and$\gamma$ : 0.845, respectively.$k_{1}$ is the ratio of the depth of the maximum compressive strength of the beam -
The effects of binder content and silica sand content on the freezing and thawing resistance of lightweight polymer concrete are examined. As a result, the mass loss and pulse velocity of lightweight polymer concrete decrease with increasing binder content and silica sand content. The relative dynamic modulus and durability factor of lightweight polymer concrete reaches minimum at a silica sand content of 50% and a binder content of 28%, and is inclined to increase with increasing binder content and silica sand content.
-
The effects of polymer-binder ratio and slag content on the properties of combined wet/dry-cured polymer-modified mortars using granulated blast-furnace slag (slag) are examined. As a result, the flexural and compressive strengths of polymer-modified mortar using slag reaches a maximum at a slag content of 40%, and is inclined to increase with increasing polymer-binder ratio. The water absorption, carbonation depth and chloride ion penetration depth tend to decrease with increasing polymer-binder ratio and slag content.