Park, Jong-Chan;Shin, Hyeon-Seo;Son, Jeong-Wan;Lee, Jun;Kim, Bong-Chul;Lim, Hun-Jun
418
Subcutaneous emphysema is relatively rare postoperative complication in the oral and maxillofacial region. Most cases reported in maxillofacial area relate to the use of high-speed handpiece. However, in this case, subcutaneous emphysema was caused by compressed air blow performed during suture removal. Cone-Beam Computed Tomography was conducted to evaluate the extent of diffusion bubbles.. In this report, we describe etiology, diagnosis, prevention and management of subcutaneous emphysema in the maxillofacial area.