• Title/Summary/Keyword: %25V

Search Result 5,013, Processing Time 0.04 seconds

Culture of Potted $Viola{\times}wittrockiana$ 'Majestic GT Scarlet Shadow' in Various Mixtures of Recycled Perlite and CGF in a Mat Subirrigation System (재사용한 펄라이트 및 다공성 CGF의 혼합배지와 매트저면관수를 이용한 분화$Viola{\times}wittrockiana$ 'Majestic GT Scarlet Shadow'의 재배)

  • Kim Gyeong-Hee;Lee Kang-Mo;Jeong Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.239-243
    • /
    • 2006
  • This research compared growth and flowering of potted $Viola{\times}wittrockiana$ 'Majestic GT Scarlet Shadow' in various mixtures of recycled perlite and cellular glass foam (CGF). The crop was cultured in a mat subirrigation system. Numbers of leaves, opened flowers, flower buds, and branches, fresh and dry weights of shoot, leaf area, and total chlorophyll concentration were the greatest in plants grown in the medium of used perlite + granular rockwool+ peatmoss (25:50:25, v/v/v). Plant height and length of the longest root were the highest and longest, respectively, in plants grown in the medium of CGF+peatmoss (25:75, v/v). The medium of CGF+peatmoss (25:75, v/v) was better than the medium of used perlite+peatmoss (25:75, v/v) in plant growth. The medium of CGF + granular rockwool (25:75, v/v) was poorer than the medium of recycled perlite + granular rockwool (25:75, v/v).

A Study on the Cultural Characteristics of Pholiota nameko Mycelium (맛버섯 균사체의 배양 특성에 관한 연구)

  • 차월석;이동병;강시형;오동규
    • Journal of Life Science
    • /
    • v.13 no.4
    • /
    • pp.498-504
    • /
    • 2003
  • This Study was carried out to investigate the optimal mycelial growth of Pholiota nameko. The optimal medium for the mycelial growth was ME medium. The optimal temperature and pH were $25^{\circ}C$$\pm$1 and 5.5, respectively. The modified optimal medium compositions were glucose 3% (w/v), malt extract 0.25% (w/v), yeast extract 0.25% (w/v), $KH_2PO_4$ 0.046% (w/v), $K_2HPO_4$ 0.1% (w/v), $MgSO_4$$7H_2O$ 0.05% (w/v). From the result of experiments on the optimal temperature, pH and nutritional requirements, the mycelial growth of modified optimal medium was higher than that of ME medium.

Effect of temparature and salinity on the multiplication of Vibrio vulnificus (수온과 염분농도가 Vibrio vulnificus 증식에 미치는 영향)

  • Kim, Myoung-Sug;Jeong, Hyun-Do;Kim, Dae-Hee;Kim, Gwang-Seog;Cho, Ji-Young;Jun, Lyu-Jin;Kim, Jae-Hoon
    • Journal of fish pathology
    • /
    • v.19 no.1
    • /
    • pp.35-43
    • /
    • 2006
  • To analyze the safety of shellfish from the Vibrio vulnificus contamination, we investigated the multiplication of V. vulnificus in oysters keeping at different temperatures with or without shell. The numbers of V. vulnificus contaminated in oysters were more than that in artificial sea water (ASW) after artificial infection. The storage-temperature had an effect on multiplication of V. vulnificus in oysters, because the number of V. vulnificus was started to increase rapidly from just after keeping at 25℃ but no significant variation was observed at 4℃ throughout the experiment periods. In different salinity, using ASW of 5, 15, 35 ‰, the number of V. vulnificus was decreased at both 25℃ and 4℃. However, the rate of decreasing at 4℃ was faster than that 25℃. Additional, changed salinity also influenced to the decreasing rate of V. vulnificus keeping 4℃ as the highest rate in 35 ‰ ASW.

The Effect of Environmental Factor on the Survival of Marine Vibrio vulnificus (해양 Vibrio vulnificus의 생존에 미치는 환경적 요인의 영향)

  • 이봉헌;박흥재
    • Journal of Environmental Science International
    • /
    • v.5 no.2
    • /
    • pp.179-185
    • /
    • 1996
  • This study was conducted to investigate the effects of environmental factors such as temperature, salinity, pH, and UV light on-the survival of life-threatening Vibrio vulnificus. In the temperature range of 15 to $25^{\circ}C$, the numbers of V. vulnificus incieased during the 6-day incubation, but outside this range, the survival of V. vulnificus was poor. Incubation between 1 and $10^{\circ}C$ showed that V. vulnifcts survived poorly below $10^{\circ}C$. At sal:nities between 5 and 25ppt, the numbers of V. vulnificus increased or remained unchanged for 6-day. At salinities above this range, the numbers of V. vulnificus decreased. The optimal pH range was 6.5 to 8.0 and outside this range, the survival ratio of V. vulnificus was small. At 15-and $25^{\circ}C$, UV radiation was bactericidal for cultures of V, vulnificus. The counts of V. vulnificus were reduced approximately 10, 000-fold after 2h of UV light treatment at both temperatures. Above results mowed 1ha't environmental factors were effective on the survival of V. vulniucus in the environment.

  • PDF

Normalization of DBTT Size Effect far Aged 1Cr-lMo-0.25V Steel (열화된 1Cr-1Mo-0.25V강의 DBTT 크기효과 보정에 관한 연구)

  • Nam, Seung-Hun;Kim, Eom-Gi;Lee, Dae-Yeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2109-2115
    • /
    • 2001
  • Miniaturized specimen technology is useful to characterize the mechanical behavior when it is difficult to sample the material enough for the test. In this study, two kinds of miniaturized Charpy impact specimens(i.e., miniaturized specimen with side groove and without side groove) of aged 1Cr- lMo-0.25V steel were prepared and tested. The relationship between the extent of degradation in terms of ductile brittle transition temperature(DBTT) and the fracture stress of 1Cr-1Mo-0.25V steel was established. The fracture stress obtained from miniaturized specimen without side groove turned out to be linearly related with the DBTT of standard specimen. Therefore the fracture toughness of aged turbine rotor steel might be evaluated by the fracture stress. In addition, the correlation between DBTT of standard specimen and that of miniaturized specimen was investigated. As the results of normalizing DBTT by maximum elastic tensile stress, the normalized DBTT of miniaturized specimen without side groove allows one to estimate that of standard specimen.

Temperature Rise Prediction of 25.8kV 25kA Three-phase GIS Bus Bar (25.8kV 25kA 3상 GIS 모선의 온도상승 예측)

  • Kim, Joong-Kyoung;Hahn, Sung-Chin;Oh, Yeon-Ho;Park, Kyong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.894-895
    • /
    • 2007
  • This paper presents coupled analysis between finite element method and analytic technique for predicting temperature rise of 25.8kV 25kA three-phase GIS bus bar. The power losses and temperature distribution of three-phase GIS bus bar model are analyzed by magneto-thermal finite element method. The heat transfer coefficients on the boundaries are analytically calculated by applying Nusselt number considering material constant and model geometry for the natural convection. And these are used as the input data to predict the temperature rise of three-phase GIS bus bar model by coupled magneto-thermal F.E.A. The predicted temperature of 25.8kV 25kA three-phase GIS bus bar model shows good agreement with the experimental data.

  • PDF

Pathogenic Vibrio spp. Isolated from the Gwangan Beach of Busan, 2002

  • Park Mi-Yeon;Kim Hyun-Jin;Chang Dong-Suck
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.3
    • /
    • pp.105-109
    • /
    • 2003
  • Fifty four strains of pathogenic vibrios were isolated from the Gwangan Beach from May to October, 2002. The isolated vibrios were composed of 7 different species: Vibrio parahaemolyticus, V. cholerae non-O1, V. alginolyticus, V. vulnificus, V. hollisae, V. fluvialis, ane V. mimicus. In the detection rate, V. parahaemolyticus was most predominant as $46\%$(25/54). From the isolated strains, only 25 strains have hemolytic activity or 25 strains only proteolytic activity on agar plates. Eleven strains showed both hemolytic and proteolytic activity. No strains showed urease activity. All strains of V parahaemolyticus did not show hemolytic activity, while V. cholerae non-O1 strains showed $\beta$ hemolytic activity. Kanagawa phenomena of pathogenic vibrios did not accord with hemolytic activity of the culture supernatant at the late log phase. Some strains showed high hemolytic activity despite having proteolytic activity, but some weak hemolytic activities despite having no proteolytic activity.

The Development of Gas Bushing for 25.8kV/2000A GCB (25.8kV 2000A GCB용 개스붓싱 개발)

  • Kim, J.B.;Song, W.P.;Lee, C.H.;Noh, C.W.;Jang, W.Y.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1385-1387
    • /
    • 1994
  • For the development of the 25.8kV outdoor GCB (Gas - Circuit - Breaker), which have a surge surpression performance in closing & opening of circuit and a high reliability performance, we have developed the 25.8kV gas bushing first of all in KOREA. After manufacturing of 25.8kV/2000A gas bushing, we carried out the dimension & visual test and electrical & mechanical test and we have got the favorable test-results. And it was put together real outdoor GCB, and then we carried out type test at KERI and have confirmed the performance of this bushing.

  • PDF

Characteristics of Redox Flow Battery Using the Soluble Lead Electrolyte (납이 용해된 전해액을 사용하는 레독스 플로우 전지의 특성)

  • An, Sang-Yong;Kim, Eung-Jin
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.214-218
    • /
    • 2011
  • The electrochemical characteristics and performance of redox flow battery using the soluble lead has been evaluated. Cyclic voltammetry was performed on the materials to evaluate deposition and dissolution of lead and lead dioxide. In the negative region, a reduction peak is not observed, and on the reverse scan, on-set voltage is observed at -0.47 V(vs SCE). In the positive region, the distinct peak is observed on the forward and reverse scan. The charge/discharge experiments were carried out graphite electrode in the beaker cell. The charging(deposition) of lead occurs at around 0.5 V(vs SCE) and discharging(dissolution) of lead occur at around 0.25 V(vs SCE). The potential difference is about 0.25 V. The charging(deposition) of dioxide lead is at 1.77 V(vs SCE) and discharging(dissolution) is at around 0.95 V(vs SCE) during first cycle. On subsequent cycles, the charging of dioxide lead starts at below 1.5 V(vs SCE), after a period the voltage increase to 1.7 V(vs SCE). The voltage of discharging is stable at around 1.0 V(vs SCE).