• Title/Summary/Keyword: 0 mode

Search Result 4,571, Processing Time 0.04 seconds

Effects of coarse mode aerosol on the size distribution by coagulation and condensation processes (응집 및 응축과정에 의한 대기 에어로졸 크기 분포에서의 coarse mode의 영향)

  • 정창훈;김용표;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.158-159
    • /
    • 2000
  • 내기중의 입자 (aerosol)는 크게 직경이 0.01-0.1 $\mu\textrm{m}$ 대의 Aitken mode와 0.1-1 $\mu\textrm{m}$ 부근의 accumulation mode, 그리고 1 $\mu\textrm{m}$ 이상의 coarse mode로 분류할 수 있으며 대기 중에서 부유하여 서로응집(coagulation) 과 응축(condensation)풍의 과정을 겪으며 변화한다. 일반적으로 Aitken mode 의 입자들은 nucleation 둥에 의해 발생된 입자이며, accumulation mode는 Aitken mode입자간의 응집, 인위적인 배출 둥에 의하여 생성된 입자이다. Coarse mode는 주로 자연적으로 생성된 입자이며 주로 침적에 의해 제거된다. (중략)

  • PDF

A Study on the Photoneutron Dose Estimation in Flattening Filter Mode and Flattening Filter Free Mode for Medical Linear Accelerator (의료용 선형가속기의 Flattening Filter Mode와 Flattening Filter Free Mode 간에 광중성자 선량 평가)

  • Yang, Oh Nam;Lim, Cheong Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.297-302
    • /
    • 2017
  • In this study, the generation of photoneutrons between the 10 MV FF mode and the FFF mode was evaluated and the amount of photoneutrons generated by the 10 MV and 15 MV energy changes in the FFF mode was evaluated. The generated neutrons were evaluated at 13 measurement points and the KTEPC was used to collect the generated neutrons. 10 MV FF mode was measured at 10 MV FF mode and FFF mode at all measurement points. In the superior direction, 0.455mSv and 0.152mSv were the largest, and more than 33% optical neutron was generated in FF. 10 MV in FFF mode, 15 MV in 15 MV, and 0.402 mSv in the direction of Superior, and 6.9% in the direction.

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

Mode Selection of Leaky Lamb Waves in Steel Plate

  • Lee, Ju-Won;Kim, Jeong-Tae;Cho, Hyun-Man;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • The dispersion and attenuation of Lamb and Leaky Lamb waves propagating in a 1 mm-thick steel plate were investigated. For acquiring a long(or large) range inspection capability, the fundamental symmetric and anti-symmetric wave modes(S0 and A0) over law frequencies were studied. Based on the dispersion curves, as well as pitch-catch and multi-mode simulations, it was shown that the S0 mode over law frequencies is the proper mode to minimize the dispersion and attenuation. In addition, it was shown that the S0 mode couldbe easily distinguished under multi-mode simulation since it has a larger group velocity than the A0 mode.

A High-Efficiency, Robust Temperature/voltage Variation, Triple-mode DC-DC Converter (고효율, Temperature/voltage 변화에 둔감한 Triple-mode CMOS DC-DC Converter)

  • Lim, Ji-Hoon;Ha, Jong-Chan;Kim, Sang-Kook;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.1-9
    • /
    • 2008
  • This paper suggests the triple-mode CMOS DC-DC converter that has temperature/voltage variation compensation techniques. The proposed triple-mode CMOS DC-DC converter is used to generate constant or variable voltages of 0.6-2.2V within battery source range of 3.3-5.5V. Also, it supports triple modes, which include Pulse Width Modulator (PWM) mode, Pulse Frequency Modulator (PFM) mode and Low Drop-Out (LDO) mode. Moreover, it uses 1MHz low-power CMOS ring oscillator that will compensate malfunction of chip in temperature/voltage variation condition. The proposed triple-mode CMOS DC-DC converter, which generates output voltages of 0.6-2.2V with an input voltage sources of 3.3-5.5V, exhibits the maximum output ripple voltage of below 10mV at PWM mode, 15mV at PFM mode and 4mV at LDO mode. And the proposed converter has maximum efficiency of 93% at PWM mode. Even at $-25{\sim}80^{\circ}C$ temperature variations, it has kept the output voltage level within 0.8% at PWM/PFM/LDO modes. For the verification of proposed triple-mode CMOS DC-DC converter, the simulations are carried out with $0.35{\mu}m$ CMOS technology and chip test is carried out.

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.

A Hybrid Resonant Mode Identification using Non-decaying Mode Analysis in Dielectric Loaded Cylindrical Cavity Resonators (비소멸 모드 해석을 이용한 유전체 삽입 원통형 공동 공진기 하이브리드 공진 모드 구분)

  • Lee, Won-Hui;Hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.6
    • /
    • pp.655-662
    • /
    • 2003
  • A rigorous field analysis by the non-decaying mode and the contour graph method is presented for dielectric-rod loaded cylindrical cavity resonators. Resonant frequencies and the lowest order modes for this resonator are calculated. The mode charts are presented to design the resonators. TE mode(transverse electric or H mode, having no Ez), TM mode(transverse magnetic or I mode, having no ㎐) and HEM mode(hybrid electromagnetic mode, having non-zero Ez and ㎐) are analyzed in detail using non-decaying mode method. The mode charts are completed. The validity of the theory is confirmed by experiments. The results were on the whole satisfactory. Experimental measurements show excellent agrement with the numerical results. The average error of TE, TM, and HEM mode is about 0.20 %, 0.14 %, and 0.28 %, respectively.

A study of mixed-mode interlaminar fracture toughness of graphite/epoxy composite (炭素纖維强化 複合材料의 혼합모우드 層間破壞靭性値에 대한 硏究)

  • 윤성호;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.2
    • /
    • pp.198-207
    • /
    • 1986
  • This study investigates interlaminar fracture characteristics of Graphite/Epoxy composite (HFG Graphite/Epoxy) under mode I (opening mode), mode II (sliding mode) and mixed mode loading conditions. The effects on interlaminar fracture toughness due to different fiber orientations on the crack surface are also investigated. The antisymmetric test fixture proposed by M. Arcan is used for this test. Both critical stress intensity foctors and critical energy release rates were determined and several mixed mode fracture criteria were compared to the experimental data. Also fracture surfaces were investigaed to obtain informations on the fracture behaviors of Graphite/Epoxy composite by means of a scanning electron microscope(SEM).

Accurate Measurements of the Unloaded Q of a Dielectric-loaded High-Q $TE_{01{\delta}}$ mode Cavity Resonator with HTS Endplates

  • Kwon, H.J.;Hur, Jung;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.36-41
    • /
    • 1999
  • Methods for mode identification and accurate measurements of the unloaded Q ($Q_0$) of a dielectric-loaded $TE_{01{\delta}}$ mode cavity resonator with HTS endplates are proposed. A resonator with a sapphire rod and $YBa_2Cu_3O_{7-x}$(YBCO) endplates was prepared and its microwave properties were studied at temperatures above 30 K. The $TE_{01{\delta}}$ mode $Q_0$ of the resonator, designed to work as a tunable resonator with variations in the gap distance (s) between the sapphire rod and the top YBCO, was more than 1000000 at s = 0 mm and at 30 K with the resonant frequency of 19.56 GHz. The $TE_{01{\delta}}$ mode $Q_0$ decreases as s increases for s < 2 mm until mode couplings between the $TE_{01{\delta}}$ mode and other modes appeared at s = 2 mm. Significant dependence of the $TE_{01{\delta}}$ mode $Q_0$ on the input and output coupling constants was also observed. Applications of the open-ended $TE_{01{\delta}}$ mode cavity resonator for a tunable resonator with a very high Q as well as a characterization tool for the surface resistance measurements of HTS films are described.

  • PDF

A Study Comparing the Effects of Burst Mode and High Rate Mode Transcutaneous Electrical Nerve Stimulation on Experimental Pain Threshold and Skin Temperature (Burst형과 고빈도형 경피신경전기자극치료가 실험적 동통역치와 체온에 미치는 영향 비교)

  • Kim, Suhn-Yeop;Choi, Houng-Sik;Kwon, Oh-Yun
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.2
    • /
    • pp.465-479
    • /
    • 1995
  • We randomly assigned 61 healthy subjects(male 14, female 47) to compare the experimental pain threshold and skin temperature between high mode TENS and burst mode TENS. In this study, 61 subjects were divided into three groups ; high mode TENS(n=20), burst mode TENS (n=20), and control group(n=21). Experimental pain thresholds and skin temperatures were measured before, immediately after cessation of stimulation, and at 30 minutes post stimulation. Stimulation was applied to the dorsal surface of the forearm(L14, LI10). Pain thresholds were measured by chronaxie meter. Skin temperature were measured by electrical digital thermometer. The results are as follows ; 1. There were no statistical difference in the pain threshold and skin temperature at before TENS stimulation among the three groups(p>0.05). 2. The pain threshold and skin temperature in burst mode TENS group was significantly higher and longer effect than that in high mode TENS group and control group(p<0.01). 3. The pain threshold in burst mode TENS group decreased to prestimulation levels by 30 minutes poststimulation. 4. The skin temperature in burst mode TENS group decreased to prestimulation levels by 20 minutes poststimulation. 5. The skin temperature was significantly difference among three group at immediately after, and at 30 minutes poststimulation and the skin temperature in burst mode TENS group was significantely higher than that in two groups(p<0.001). 6. The increasing rate of pain threshold in high mode TENS group after immediately cassation of stimulation was 24.3%(p<0.001). 7. The increasing rate of pain threshold in burst mode TENS group after immediately cessation of stimulation was 93.5% (p<0.001).

  • PDF