• Title/Summary/Keyword: 2-probe method

Search Result 755, Processing Time 0.028 seconds

Application of DNA Probe Method for Detection of 2,4-Dichlorophenoxyacetic Acid Degrading Bacteria in Soil (DNA Probes에 의한 토양의 이사디 (2,4-D) 분해세균의 검출)

  • Ka, Jong-Ok
    • Applied Biological Chemistry
    • /
    • v.39 no.5
    • /
    • pp.403-408
    • /
    • 1996
  • Total bacterial community DNA, which was extracted from microcosm soil and field soil after 2,4-D amendments, was analyzed on Southern blots, using the tfdA gene probe derived from plasmid pJP4 and the Spa probe from Sphingomonas paucimobilis. Southern blot analyses with total bacterial DNA extracted from soils Inoculated with Pseudomonas cepacia/pJP4 revealed that DNA probe method could detect the 2,4-D degrading bacteria down to $10^5\;cells/g$ dry soil. In the microcosm experiment, there was a good correlation between 2,4-D degradation and banding patterns in hybridization analyses performed after each 2,4-D treatment using the two probes. When bacterial DNA extracted from microcosm soil was hybridized with the Spa probe, a change in the position of hybrid bands was observed over time in a Southern blot, suggesting that population change or possibly genetic rearrangement in 2,4-D degrading microbial populations occurred in this soil. With the Spa probe, one hybrid DNA band was persistently observed throughout the five 2,4-D additions. When bacterial DNA isolated from the field soil was probed with the tfdA and Spa, strong hybridization signal was observed in the 100 ppm-treated subplot, weak signal In the 10 ppm-treated subplot, and no significant signal in the 1 ppm-treated and control subplots. The data show that DNA probe analyses were capable of detecting and discriminating the indigenous 2,4-D degrading microbial populations in soil amended with 2,4-D under laboratory and field conditions.

  • PDF

Evaluation Technology of Degradation of Metallic Alloy using Electrical Resistivity (전기비저항을 이용한 금속합금 열화도 평가기술)

  • Nahm, Seung-Hoon;Yu, Kwang-Min;Ryu, Jae-Cheon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.532-541
    • /
    • 2001
  • Developments of nondestructive evaluation techniques for reduction of strength or toughness by aging of material have been carried out, and the method using electrical resistivity is one of them. In this study, to examine the application of electrical resistivity to the evaluation of degradation of metallic alloy, ten different non-magnetic materials were selected as test materials. Electrical resistivities measured by DC two-point probe method and those measured by non-contact type eddy current method were compared with each other. In addition, to examine the application possibility of four-point probe technology in field, the electrical resistivities for 1Cr-lMo-0.25V steel measured by DC two-point probe method and four-point probe method were compared with each other Differences between two measured values for the 1Cr-1Mo-0.25V steel were 0.6%. Therefore, the four-point probe method can be applied to the estimation of the degradation of metallic alloy. ect.

  • PDF

Development of Hand-Held Type Sheet Resistance Meter Based on a Dual-Configuration Four-Point Probe Method (Dual-Configuration Four-Point Probe Method에 의한 휴대형 면저항 측정기 개발)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Wan-Seop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.423-427
    • /
    • 2010
  • Portable sheet resistance-measuring instrument using the dual-configuration Four-Point Probe method is developed for the purpose of precisely measuring the sheet resistance of conducting thin films. While single-configuration Four-Point Probe method has disadvantages of applying sample size, shape and thickness corrections for a probe spacing, the developed instrument has advantages of no such corrections, little edge effects and measuring simply and accurately the sheet resistance between $0.2\Omega/sq$ and $2k\Omega/sq$.

The simultaneous measurement for thermal properties of liquids using transient probe method (과도탐침법을 이용한 액체의 열물성 동시측정)

  • Bae, Sin-Cheol;Kim, Myeong-Yun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.2
    • /
    • pp.303-315
    • /
    • 1997
  • The theoretical model for the transient probe method is the modified Jaeger model which is used perfect line source theory. The transient probe technique has been developed for the simultaneous determination of thermal conductivity, diffusivity and volumetric heat capacity of liquids. The Levenberg-Marquardt iteration method is adapted to obtain thermal property within nonlinear range. Experimental results of liquids were found to agree well with recommended thermal property data.

The comparison of critical currents measured by hall probe and transport methods for HTS coated conductor

  • Lee, Nam-Jin;Oh, Sang-Soo;Kim, Ho-Sup;Ha, Dong-Woo;Ha, Hong-Soo;Ko, Rock-Kil;Kim, Tae-Hyung;Kim, Hae-Jong;Song, Kyu-Jeong;Moon, Seung-Hyun;Youm, Do-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.11-14
    • /
    • 2009
  • We estimated the critical current distribution of the long length CCs using hall probe method, and checked the reliability by comparing with the four-probe dc transport method. The deviation ratio of $I_{c-T}$ (a measured critical current by four probe dc transport method) and $I_{c-H}$ (calculated critical current by formula (3).) was nearly smaller than 12%. The Hall probe method appeared powerful to evaluate the critical current of CCs in a reel to reel system.

A Study on the Sensitivity Compensation of Three-dimensional Acoustic Intensity Probe in the Higher Frequency Range (3차원 음향 인텐시티 프로브의 고주파 영역 감도 보상 연구)

  • Kim, Suk-Jae;Hideo, Suzuki;Kim, Chun-Duck
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.40-50
    • /
    • 1994
  • In this paper, the sensitivity compensation method for three-dimensional acoustic intensity probe in the higher frequency range has been studied. The measurement error in the higher frequency range is generated from the phase mismatch between microphone's signals of the probe. If the wavelength of sound signal measured is less than those of the distance between microphones of the probe, that is, the higher frequency of the sound signal, the bigger measurement error is generated. In this study, we proposed the compensation methods for one-dimensional acoustic intensity probe with two-microphones, and the efficiency of those methods were investigated by numerical calculation of computer. It was most effective method to compensate the phase mismatch between microphone for the acoustic intensity probe was investigated for the sound estimated. and the efficiency of this method in a three-dimensional probe was investigated for the sound wave travelling in the arbitrary direction by numerical calculation of computer. In this result, the efficiency was proved that, for the measurement error of 1dB or less with the three-dimensional probe of 60mm space, the frequency should be less than 1.2kHz without the error compensation method, but the frequency increased up to 2.8kHz with the error compensation method.

  • PDF

A study on fast langmuir probe driving circuit for measurement of plasma parameter and its application (플라즈마 파라메타 측정용 고속 langmuir프로브 구동회로 실현 및 적용)

  • 신중흥;고태언;김두환;박정후
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.506-511
    • /
    • 1996
  • This paper deals with an inexpensive, simple and fast Langmuir probe sweeping circuit and its application. This sweeper completes a probe trace in a 1 ms order. Futhermore, the circuit drives a maximum probe voltage of $\pm$30V and has a maximum probe current capability of a few amperes. The plasma parameters are successfully determined using the fast Langmuir probe method.

  • PDF

Silicon Oil-Based 2-Channel Fiber-Optic Temperature Sensor Using a Subtraction Method (감법을 이용한 실리콘 오일 기반의 2채널 광섬유 온도 센서)

  • Lee, Dong Eun;Yoo, Wook Jae;Shin, Sang Hun;Kim, Mingeon;Song, Young Beom;Kim, Hye Jin;Jang, Kyoung Won;Tack, Gye Rae;Lee, Bongsoo
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.344-348
    • /
    • 2016
  • We developed a 2-channel fiber-optic temperature sensor (FOTS) using a temperature sensing probe, a fiber-optic coupler, transmitting optical fiber, and an optical time domain reflectometer (OTDR). The temperature sensing probe is divided into a sensing probe and a reference probe for accurate thermometry. A sensing probe is composed of a silicon oil, a FC terminator, a brass pipe, and a singlemode optical fiber and the structure of a reference probe is identical with that of the sensing probe excluding a silicon oil. In this study, we measured the modified optical powers of the light signals reflected from the temperature sensing probe placed inside of the water with a thermal variation from 5 to $70^{\circ}C$. Although the optical power of the reference probe was constant regardless of the temperature change, the optical power of the sensing probe decreased linearly as the temperature increased. As experimental results, the FOTS using a subtraction method showed a small difference (i.e., hysteresis) in its response due to heating and cooling. The reversibility and reproducibility of the FOTS were also evaluated.

A development of accuracy diagnostic system 2-dimensional circular interpolation of machining centers (Machining Center의 2차원 원호보간정밀도 진단 System의 개발)

  • Kim, Jeong-Soon;Namgung, Suk;Tsutusmi, Masacmi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.54-65
    • /
    • 1993
  • The paper describes and alternative method based on a new idea to measure the circular movement of machining centers. ISO has employed three testing methods for the acceptance tests of machine tools; the first is a rotating one-dimensional probe method, the second is a two-dimensional probe and a master circular ring, and the third is a kinematic ball bar. The last two methods were proposed and introduced by W. Knapp and J. B. Bryan, respectively. The newly developed method is superior to above two methods; the rotating angle can be detected and the rotating radius is variable. Circular movement errors of machining centers were investigated by the analysis of data measured by R- .THETA. method. Followint observations are obtained 1) The errors which depend on positions, i.e., periodical errors by the pitch of ball screws, errors by compensation of backlash and errors by perpendicularity of X and Y-axis, were analyzed. 2) The errors which depend on NC control system, i.e., errors by the unbalance of position-loop-gaians, errors by velocity-loop-gains and errors by feed speeds, were quantiatively analyzed. 3) The method of extracting error information, which uses moving technique of averaging angle and fourier's analysis data mesured by the R- .THETA. method, was proposed.

  • PDF

COMPARATIVE STUDY ON THE DETECTION OF PORPHYROMONAS ENDODONTALIS BY ANAEROBIC CULTURE, IIF AND DNA PROBE METHOD IN INFECTED ROOT CANALS (감염 근관에서 혐기성 배양법과 간접 면역 형광법 및 DNA 프로브법에 의한 Porphyromonas endodontalis의 검출에 관한 비교 연구)

  • Kim, Min-Kyum;Yoon, Soo-Han;Chung, Chong-Pyoung
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.1-18
    • /
    • 1996
  • There are many advantages when using IIF and DNA probe methods over anaerobic culture method in that they are time-and effort-saving, more precise and more sensitive. Furthermore, in IIF and DNA probe methods, the detection is possible only with small amount of bacteria, the quantitative analysis is possible, and the cell viability is not necessary. The purpose of this study is to observe the incidence of P.endodontalis by carrying out anaerobic culture, IIF and colony lift using DNA probe method respectively, and to compare these 3 methods in terms of effectiveness and sensitivity in order to identify the most effective detection method. 30 teeth with at least one clinical symptoms, with single canal, and with pulp necrosis were sampled. For sampling bacteria, access cavity was prepared after disinfecting tooth and its surroundings. Then the paper point was inserted up to the periapical area, leave there for a while, and finally it was placed into PRAS Ringer's sol. and PBS sol. In anaerobic culture method, P.endodontalis was identified by biochemical tests after subculturing black and brown colonies which were produced after 7 days of incubation on BAP and Brucella BAP in anaerobic chamber. To identify P.endodontalis in IIF method, species-specific polyclonal rabbit-antisera of P.endodontalis(ATCC 35406) was reacted with sampled PBS sol. dispensed onto glass slide, and then P.endodontalis was examined by phase contrast microscopy after incubating with Goat anti-rabbit lgG conjugated to Fluorescein isothiocyanate. For colony lift using DNA probe method, membranes were laid over colonies on the surface of BAP and were hybridized with cloned DNA probe of P.endodontalis. The existence of P.endodontalis was then identified by the methods of chemiluminescent detection and color metric detection. Black colony was found in 11 teeth out of 30 teeth and P.endodontalis was detected in 6 teeth (20 %) by anaerobic culture method, 16 teeth (53 %) by IIF method, and 7 teeth (23 %) by DNA probe method. IIF method is significantly better in detecting P.endodontalis than DNA probe method and anaerobic culture method. There was no significant differences between DNA probe method and anaerobic culture method. There was significant correlation between the formation of black colony and the existence of P.endodontalis. The probability of detecting P.endodontalis when black colony being present is 2.89 times higher than when not being present. There was significant relationship between the foul odor of clinical symptoms and P.endodontalis. The sensitivity of existing P.endodontalis when foul odor being present was 93.75 %, while the specificity of not existing P.endodontalis when foul odor not being present was 28.57 %. These results suggested that the probes of P.endodontalis will be used to decide the method and prognosis in endodontic treatments.

  • PDF