• Title/Summary/Keyword: 3D Measurement System

Search Result 1,272, Processing Time 0.031 seconds

A System for Measuring 3D Human Bodies Using the Multiple 2D Images (다중 2D 영상을 이용한 3D 인체 계측 시스템)

  • 김창우;최창석;김효숙;강인애;전준현
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.1-12
    • /
    • 2003
  • This paper proposes a system for measuring the 3D human bodies using the multiple 2D images. The system establishes the multiple image input circumstance from the digital camera for image measurement. The algorithm considering perspective projection leads us to estimate the 3D human bodies from the multiple 2D images such as frontal. side and rear views. The results of the image measurement is compared those of the direct measurement and the 3D scanner for the total 40 items (12 heights, 15 widths and 13 depths). Three persons measure the 40 items using the three measurement methods. In comparison of the results obtained among the measurement methods and the persons, the results between the image measurement and the 3D scanner are very similar. However, the errors for the direct measurement are relatively larger than those between the image measurement and the 3D scanner. For example, the maximum errors between the image measurement and the 3D scanner are 0.41cm in height, 0.39cm in width and 0.95cm in depth. The errors are acceptable in body measurement. Performance of the image measurement is superior to the direct. because the algorithm estimates the 3D positions using the perspective projection. In above comparison, the image measurement is expected as a new method for measuring the 3D body, since it has the various advantages of the direct measurement and 3D scanner in performance for measurement as well as in the devices, cost, Portability and man power.

Development of a 3-D Position Measurement Algorithm using 2-D Image Information (2차원 영상 정보를 이용한 3차원 위치 측정 알고리즘 개발)

  • Lee, J.H.;Jung, S.H.;Kim, D.H.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.141-148
    • /
    • 2013
  • There are several problems in the conventional 2-D image processing and 3-D measurement systems. In the case of the 2-D image processing system, it is not possible to detect elevation data. In a 3-D measurement system, it requires a skillful operator and a lot of time for measuring data. Also, there exist data errors depending on operators. The limitation of detecting elevation data in the 2-D image processing system can be solved by laser diodes. In this study an algorithm that measures the accurate data in a subject face to be detected by combining laser diodes and a commercial CCD camera is developed. In the development process, a planar equation is developed using laser diodes and the equation is used to obtain a normal vector. Based on the results, an algorithm that transforms commercial CCD camera coordinates to 3-D coordinates is proposed. The completed measurement method will be applied to replace a manual measurement system for vehicle bodies and parts by an automated system.

Comparison of Size between direct-measurement and 3D body scanning (중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구)

  • Cha, Su-Joung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

3-D Measurement of LED Packages Using Phase Measurement Profilometry (위상측정법을 이용한 LED Package의 3차원 형상 측정)

  • Koo, Ja-Myoung;Cho, Tai-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • LEDs(Light Emitting Diodes) are becoming widely used and increasingly in demand. Quality inspection of the LEDs has become more important. Two-dimensional inspection systems are limited in inspection capability, so threedimensional(3-D) inspection systems are needed. In this paper, a cost-effective and simple 3-D measurement system of LED packages using phase measuring profilometry(PMP) is proposed. The proposed system uses a pico projector to project sinusoidal fringe patterns and to shift phases instead of piezocrystal. It was evaluated using extremely accurate gauge blocks, yielding excellent repeatability of about 12 um(3-sigma). 3-D measurements of various LED packages were performed to demonstrate the applicability and efficiency of the proposed system.

Development of Shape Measurement System using 3 Dimension (3차원을 이용한 형상측정기 개발)

  • Lee, M.H.;Park, K.S.;Bae, J.I.;Kim, J.K.;Ahn, D.S.;Song, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2628-2630
    • /
    • 2001
  • This paper developed a 3D inspection system. The system consists of two parts : one includes hardwares such as actuators, linear scales and a probe, etc. the other involves softwares for management and control of the system. Compared with existing 3D measurement systems, this system achieved automatically the inspection. This automatic inspection makes the system have some advantages to reduce a measurement time and to be easily used by operators.

  • PDF

A Study on the 3-D Deformation Analysis for Safety Diagnosis of Bridges (교량의 안전진단을 위한 3차원 변형해석에 관한 연구)

  • 강준묵;윤희천;배상호
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.13 no.1
    • /
    • pp.69-76
    • /
    • 1995
  • This study is the 3-D precision deformation measurement of a bridge, obtain results of precision control points by GPS and 3-D measurement system and develope efficientlty technices which can solve precision 3-D analysis by CRP In the result, we could overcome the problems of former control point measurement in the way of the combination system of GPS and 3-D measurement system to positioning decision of reference points and control points. Then we could symplify old measurement process on the 3-D deformation analysis of a linear structure and complement parted analysis fault of measurement instrument.

  • PDF

Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter (레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발)

  • 배기윤;이정인
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.

Development of a Noncontact Three Dimensional Foot Form Measurement System with a Stereo Vision Method (스테레오 비젼을 이용한 비접촉 3차원 족형 측정 시스템 설계)

  • 김시경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.11
    • /
    • pp.1017-1021
    • /
    • 2004
  • In this paper, a cost-effective integrated 3D system for measuring and sizing foot is proposed. The proposed system employs two CCDs and a laser line projector which are capable of accurately measuring foot. The measurement is based upon the biologically motivated stereo vision principle providing ruggedness against minor system distortions. According to the tolerance, calibration between two different views are implicitly applied. Furthermore, the measurement system employs a measurement base, a frame grabber, a CCD moving cart, a stepping motor and computer. Analysis and design procedure is presented for the calculation of the 3D foot data and the proposed system. Experimental results on the proposed system would verify the concept and system operation.

Validity and Reliability of an Inertial Measurement Unit-Based 3D Angular Measurement of Shoulder Joint Motion

  • Yoon, Tae-Lim
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.145-151
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the validity and reliability of the measurement of shoulder joint motions using an inertial measurement unit (IMU). Methods: For this study, 33 participants (32 females and 1 male) were recruited. The subjects were passively positioned with the shoulder placed at specific angles using a goniometer (shoulder flexion $0^{\circ}-170^{\circ}$, abduction $0^{\circ}-170^{\circ}$, external rotation $0^{\circ}-90^{\circ}$, and internal rotation $0^{\circ}-60^{\circ}$ angles). Kinematic data on the shoulder joints were simultaneously obtained using IMU three-dimensional (3D) angular measurement (MyoMotion) and photographic measurement. Test-retest reliability and concurrent validity were examined. Results: The MyoMotion system provided good to very good relative reliability with small standard error of measurement (SEM) and minimal detectable change (MDC) values from all three planes. It also presented acceptable validity, except for some of shoulder flexion, shoulder external rotation, and shoulder abduction. There was a trend for the shoulder joint measurements to be underestimated using the IMU 3D angular measurement system compared to the goniometer and photo methods in all planes. Conclusion: The IMU 3D angular measurement provided a reliable measurement and presented acceptable validity. However, it showed relatively low accuracy in some shoulder positions. Therefore, using the MyoMotion measurement system to assess shoulder joint angles would be recommended only with careful consideration and supervision in all situations.

Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant (화력발전소 주배관 3차원 변위측정시스템 개발)

  • Song, G.W.;Hyun, J.S.;Ha, J.S.;Cho, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF